Storm overflow register · Dwr Cymru Welsh Water

Shobdon sewage works: storm overflow spills 2025

Shobdon sewage treatment works, run by Dwr Cymru Welsh Water, has 1 monitored storm overflow discharging to Pinsley Brook. In 2025 it recorded 122 spills totalling 700 hours, against 166 spills and 1,169 hours in 2024. By hours spilling, it ranks 3 of 26 Dwr Cymru Welsh Water works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecShobdon STW6 spills, 2 h, 1 Jan to 1 Jan27 spills, 60.5 h, 5 Jan to 9 Jan14 Jan 2025 15:45 GMT, 15 min18 Jan 2025 10:30 GMT, 15 min88 spills, 119.3 h, 23 Jan to 3 Feb4 spills, 1.3 h, 4 Feb to 4 Feb3 spills, 1 h, 5 Feb to 5 Feb2 spills, 0.5 h, 7 Feb to 8 Feb6 spills, 1.8 h, 9 Feb to 9 Feb3 spills, 0.8 h, 10 Feb to 11 Feb17 spills, 8.5 h, 14 Feb to 18 Feb2 spills, 0.5 h, 20 Feb to 20 Feb21 Feb 2025 10:45 GMT, 15 min34 spills, 44 h, 23 Feb to 27 Feb2 Mar 2025 17:00 GMT, 15 min2 spills, 0.5 h, 6 Mar to 6 Mar8 Mar 2025 09:30 GMT, 15 min9 Mar 2025 11:30 GMT, 15 min10 Mar 2025 07:15 GMT, 15 min5 spills, 1.3 h, 11 Mar to 12 Mar13 Mar 2025 08:30 GMT, 15 min14 Mar 2025 08:15 GMT, 15 min2 spills, 0.5 h, 16 Mar to 16 Mar2 spills, 0.5 h, 17 Mar to 18 Mar20 Mar 2025 09:00 GMT, 15 min21 Mar 2025 13:30 GMT, 15 min22 Mar 2025 18:30 GMT, 15 min2 spills, 0.5 h, 24 Mar to 24 Mar2 spills, 0.8 h, 21 Apr to 21 Apr2 spills, 2 h, 22 Apr to 23 Apr1 May 2025 16:15 GMT, 30 min11 May 2025 19:45 GMT, 15 min2 spills, 1 h, 3 Jun to 3 Jun12 Jun 2025 12:15 GMT, 60 min14 Jun 2025 04:45 GMT, 30 min20 Jul 2025 11:15 GMT, 45 min31 Jul 2025 01:15 GMT, 45 min28 Aug 2025 15:00 GMT, 30 min3 Sep 2025 12:30 GMT, 60 min4 Sep 2025 08:00 GMT, 75 min2 spills, 1.3 h, 7 Sep to 7 Sep13 Sep 2025 01:45 GMT, 60 min2 spills, 5.5 h, 14 Sep to 14 Sep3 spills, 5.8 h, 20 Sep to 20 Sep3 Oct 2025 13:00 GMT, 105 min4 spills, 2.5 h, 22 Oct to 23 Oct24 Oct 2025 17:15 GMT, 60 min2 spills, 1.5 h, 30 Oct to 31 Oct6 spills, 9 h, 4 Nov to 5 Nov2 spills, 0.5 h, 6 Nov to 6 Nov10 Nov 2025 13:00 GMT, 45 min13 spills, 14 h, 11 Nov to 13 Nov10 spills, 46.5 h, 14 Nov to 16 Nov19 Nov 2025 10:00 GMT, 15 min23 Nov 2025 06:15 GMT, 15 min24 Nov 2025 05:45 GMT, 15 min26 Nov 2025 17:00 GMT, 15 min200 spills, 350 h, 28 Nov to 23 Dec24 Dec 2025 17:45 GMT, 15 min26 Dec 2025 11:00 GMT, 15 min3 spills, 0.8 h, 29 Dec to 30 Dec31 Dec 2025 17:45 GMT, 15 min

Hours spilling by month, 2025

0100200300400Jan 2025: 174 hours spillingJanFeb 2025: 67 hours spillingFebMar 2025: 5.5 hours spillingMarApr 2025: 2.8 hours spillingAprMay 2025: 0.8 hours spillingMayJun 2025: 2.5 hours spillingJunJul 2025: 1.5 hours spillingJulAug 2025: 0.5 hours spillingAugSep 2025: 16 hours spillingSepOct 2025: 6.8 hours spillingOctNov 2025: 103 hours spillingNovDec 2025: 321 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
17 Dec 2025, 19:30Shobdon STW2.7 days
26 Jan 2025, 10:45Shobdon STW2.5 days
9 Dec 2025, 01:00Shobdon STW1.9 days
5 Jan 2025, 12:00Shobdon STW1.9 days
14 Nov 2025, 03:45Shobdon STW1.8 days

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate11,994 m³range 4,778 - 30,112 m³
In litres12.0 millionrange 4.8 million - 30.1 million L
Olympic swimming pools4.8at 2,500 m³ each
Organic load, as people's raw sewage17,991person-days of untreated BOD

Assumed spill rate while spilling: 1.9 - 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 191 kg1,079 kg6,022 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 502 kg5,097 kg21,711 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 9.1 kg76 kg280 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3-9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 5.7 kg31 kg163 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 477.8 billion organisms12.0 trillion organisms301.1 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Shobdon STW

Inlet overflow at sewage works · discharges to Pinsley Brook

Spills 2025
122 (700 hours) · down 27% on 2024
Spills 2024
166 (1,169 hours)
Long-term average
147.1 spills a year (monitored since 2017)
Monitor uptime
95% of the year
High-spill reason (company)
Not Applicable - Ongoing investigation
Investigation
No investigation activity in reporting period
Improvement
No improvement action in reporting period
WFD catchment
Pinsley Bk - source to conf R Lugg (GB109055041940)
Outlet location
SO4060060510 (OS grid reference) · View on Apple Maps
EA ID / permit
DCW00105 · AN0272501 · company name: Shobdon

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024-25 [EA]. Infiltration of groundwater into sewers is taken as 0-40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies - environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 - per capita consumption
  3. HBF: Foul sewer design - historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 - CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Dwr Cymru Welsh Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.