Storm overflow register · South West Water

Carnon Downs sewage works: storm overflow spills 2025

Carnon Downs sewage treatment works, run by South West Water, has 1 monitored storm overflow discharging to Carnon River. In 2025 it recorded 21 spills totalling 338 hours, against 8 spills and 100 hours in 2024. By hours spilling, it ranks 206 of 334 South West Water works, where 1 spilled longest.

Works size: 3,196 population equivalent (CARNON DOWNS STW, UWWTD 2018). Used for the spill volume estimate.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecCarnon Downs WwTW6 Jan 2025 02:30 GMT, 38.5 h7 Jan 2025 17:15 GMT, 60 min7 Jan 2025 18:30 GMT, 30 min7 Jan 2025 19:15 GMT, 105 min7 Jan 2025 21:15 GMT, 30 min7 Jan 2025 22:00 GMT, 15 min7 Jan 2025 22:30 GMT, 15 min7 Jan 2025 23:15 GMT, 15 min8 Jan 2025 11:30 GMT, 10.8 h8 Jan 2025 22:30 GMT, 30 min9 Jan 2025 00:00 GMT, 15 min9 Jan 2025 00:45 GMT, 15 min23 Feb 2025 22:40 GMT, 65.6 h26 Feb 2025 16:45 GMT, 30 min15 Apr 2025 23:16 GMT, 9.5 h16 Apr 2025 09:15 GMT, 15 min5 Dec 2025 15:45 GMT, 176 h13 Dec 2025 00:00 GMT, 15 min13 Dec 2025 00:30 GMT, 15 min13 Dec 2025 01:00 GMT, 15 min13 Dec 2025 01:30 GMT, 15 min15 Dec 2025 13:45 GMT, 3.3 h15 Dec 2025 17:15 GMT, 30 min15 Dec 2025 18:00 GMT, 15 min15 Dec 2025 18:30 GMT, 30 min15 Dec 2025 19:15 GMT, 15 min15 Dec 2025 19:45 GMT, 30 min15 Dec 2025 20:30 GMT, 60 min15 Dec 2025 21:45 GMT, 30 min18 Dec 2025 11:30 GMT, 6.8 h18 Dec 2025 18:30 GMT, 3.3 h18 Dec 2025 22:00 GMT, 60 min18 Dec 2025 23:15 GMT, 15 min18 Dec 2025 23:45 GMT, 30 min19 Dec 2025 00:30 GMT, 15 min19 Dec 2025 09:15 GMT, 105 min19 Dec 2025 11:15 GMT, 60 min19 Dec 2025 12:30 GMT, 90 min19 Dec 2025 14:15 GMT, 30 min19 Dec 2025 15:00 GMT, 15 min19 Dec 2025 15:45 GMT, 15 min19 Dec 2025 16:15 GMT, 15 min19 Dec 2025 16:45 GMT, 15 min19 Dec 2025 17:30 GMT, 15 min19 Dec 2025 18:00 GMT, 45 min19 Dec 2025 19:00 GMT, 30 min19 Dec 2025 19:45 GMT, 15 min19 Dec 2025 20:15 GMT, 15 min19 Dec 2025 21:00 GMT, 15 min19 Dec 2025 21:30 GMT, 15 min20 Dec 2025 17:45 GMT, 2.5 h20 Dec 2025 20:30 GMT, 30 min20 Dec 2025 21:15 GMT, 15 min

Estimated spill volume by month, 2025

Hours spilling each month × the estimated spill rate for a works of this size. The bars are central estimates and the whiskers show the low–high range. Method.

010k20k30kJan 2025: 55 h spilling ≈ 2,995 m³ (range 1,193–7,520 m³)JanFeb 2025: 66 h spilling ≈ 3,620 m³ (range 1,442–9,088 m³)FebMar 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)MarApr 2025: 9.7 h spilling ≈ 531 m³ (range 212–1,334 m³)AprMay 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)MayJun 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)JunJul 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)JulAug 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)AugSep 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)SepOct 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)OctNov 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)NovDec 2025: 207 h spilling ≈ 11,347 m³ (range 4,520–28,486 m³)Dec
Cubic metres (m³), estimate. Hours are measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDurationEstimated volume
5 Dec 2025, 15:45Carnon Downs WwTW7.3 days3,839 – 24,197 m³
23 Feb 2025, 22:40Carnon Downs WwTW2.7 days1,431 – 9,016 m³
6 Jan 2025, 02:30Carnon Downs WwTW1.6 days839 – 5,291 m³
8 Jan 2025, 11:30Carnon Downs WwTW10.8 h234 – 1,478 m³
15 Apr 2025, 23:16Carnon Downs WwTW9.5 h206 – 1,301 m³

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

Volume, central estimate18,498 m³range 7,368 – 46,441 m³
In litres18.5 millionrange 7.4 million – 46.4 million L
Olympic swimming pools7.4at 2,500 m³ each
Organic load, as people's raw sewage27,748person-days of untreated BOD

Assumed spill rate while spilling: 6.1 – 38.2 L/s (central 15.2 L/s), from a dry-weather flow of 6.1 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 295 kg1,665 kg9,288 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 774 kg7,862 kg33,484 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 14 kg117 kg432 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3–9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 8.8 kg48 kg251 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 736.8 billion organisms18.5 trillion organisms464.4 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Carnon Downs WwTW

Inlet overflow at sewage works · discharges to Carnon River

Spills 2025
21 (338 hours) · up 163% on 2024
Spills 2024
8 (100 hours)
Long-term average
160.2 spills a year (monitored since 2016)
Monitor uptime
99% of the year
Investigation
UWWTR investigation ongoing
Improvement
UWWTR improvement completed
Shellfish water
Fal Estuary
WFD catchment
Lower River Carnon (GB108048001231)
Outlet location
SW78684000 (OS grid reference) · View on Apple Maps
EA ID / permit
SBB00211 · NRA-SW-7825 · company name: CARNON DOWNS STW_SO_CARNON DOWNS

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024–25 [EA]. Infiltration of groundwater into sewers is taken as 0–40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies – environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 – per capita consumption
  3. HBF: Foul sewer design – historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 – CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All South West Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.