Storm overflow register · South West Water

East Ogwell sewage works: storm overflow spills 2025

East Ogwell sewage treatment works, run by South West Water, has 1 monitored storm overflow discharging to River Lemon. In 2025 it recorded 68 spills totalling 1,099 hours, against 92 spills and 1,533 hours in 2024. By hours spilling, it ranks 100 of 334 South West Water works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecEast Ogwell WwTW4 Jan 2025 20:09 GMT, 172.9 h23 Jan 2025 11:13 GMT, 68 min24 Jan 2025 01:40 GMT, 218.2 h2 Feb 2025 10:00 GMT, 5 h20 Feb 2025 08:31 GMT, 14.7 h21 Feb 2025 10:28 GMT, 14.1 h23 Feb 2025 12:55 GMT, 134.6 h1 Mar 2025 09:21 GMT, 5.3 h15 Apr 2025 22:37 GMT, 5.2 h18 Apr 2025 20:38 GMT, 14.1 h7 Jun 2025 14:08 GMT, 38 min12 Jun 2025 09:15 GMT, 2.5 h27 Aug 2025 09:04 GMT, 15 min29 Aug 2025 00:05 GMT, 56 min3 Sep 2025 00:39 GMT, 73 min9 Sep 2025 20:37 GMT, 54 min11 Nov 2025 18:22 GMT, 2.2 h11 Nov 2025 20:43 GMT, 2.2 h12 Nov 2025 04:40 GMT, 6.4 h13 Nov 2025 19:39 GMT, 100 min14 Nov 2025 16:48 GMT, 3.4 h1 Dec 2025 05:19 GMT, 29 min1 Dec 2025 13:50 GMT, 32.9 h4 Dec 2025 04:16 GMT, 54 min5 Dec 2025 14:01 GMT, 198.9 h15 Dec 2025 06:12 GMT, 258.2 h

Hours spilling by month, 2025

0200400600Jan 2025: 364 hours spillingJanFeb 2025: 193 hours spillingFebMar 2025: 8.8 hours spillingMarApr 2025: 19 hours spillingAprMay 2025: 0.0 hours spillingMayJun 2025: 3.1 hours spillingJunJul 2025: 0.0 hours spillingJulAug 2025: 1.2 hours spillingAugSep 2025: 2.1 hours spillingSepOct 2025: 0.0 hours spillingOctNov 2025: 16 hours spillingNovDec 2025: 491 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
15 Dec 2025, 06:12East Ogwell WwTW10.8 days
24 Jan 2025, 01:40East Ogwell WwTW9.1 days
5 Dec 2025, 14:01East Ogwell WwTW8.3 days
4 Jan 2025, 20:09East Ogwell WwTW7.2 days
23 Feb 2025, 12:55East Ogwell WwTW5.6 days

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate18,829 m³range 7,500 – 47,271 m³
In litres18.8 millionrange 7.5 million – 47.3 million L
Olympic swimming pools7.5at 2,500 m³ each
Organic load, as people's raw sewage28,244person-days of untreated BOD

Assumed spill rate while spilling: 1.9 – 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 300 kg1,695 kg9,454 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 787 kg8,002 kg34,082 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 14 kg119 kg440 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3–9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 9.0 kg49 kg255 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 750.0 billion organisms18.8 trillion organisms472.7 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

East Ogwell WwTW

Storm tank at sewage works · discharges to River Lemon

Spills 2025
68 (1,099 hours) · down 26% on 2024
Spills 2024
92 (1,533 hours)
Long-term average
92.8 spills a year (monitored since 2017)
Monitor uptime
100% of the year
High-spill reason (company)
Not asset maintenance - hydraulic capacity
Investigation
Env Act (SODRP) investigation ongoing, UWWTR investigation ongoing, Operational investigation completed
Improvement
No improvement action in reporting period
Shellfish water
Teign Estuary
WFD catchment
Lemon (GB108046008450)
Outlet location
SX84127089 (OS grid reference) · View on Apple Maps
EA ID / permit
SBB00393 · DRA 239 · company name: EAST OGWELL STW_SSO_EAST OGWELL

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024–25 [EA]. Infiltration of groundwater into sewers is taken as 0–40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies – environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 – per capita consumption
  3. HBF: Foul sewer design – historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 – CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All South West Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.