Storm overflow register · South West Water

Harrowbarrow sewage works: storm overflow spills 2025

Harrowbarrow sewage treatment works, run by South West Water, has 1 monitored storm overflow discharging to (S)Unnamed Trib River Tamar. In 2025 it recorded 68 spills totalling 628 hours, against 79 spills and 356 hours in 2024. By hours spilling, it ranks 152 of 334 South West Water works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecHarrowbarrow WwTW10 spills, 79.5 h, 4 Jan to 9 Jan3 spills, 1.1 h, 24 Jan to 24 Jan9 spills, 52.5 h, 26 Jan to 28 Jan2 spills, 1.6 h, 19 Feb to 20 Feb2 spills, 0.9 h, 21 Feb to 21 Feb6 spills, 48.7 h, 23 Feb to 26 Feb3 spills, 1.2 h, 15 Apr to 15 Apr3 spills, 1.6 h, 18 Apr to 18 Apr22 Apr 2025 20:35 GMT, 48 min3 spills, 1 h, 7 Jun to 7 Jun2 spills, 1.1 h, 12 Jun to 12 Jun13 Jun 2025 14:34 GMT, 12 min20 Jul 2025 00:18 GMT, 36 min27 Aug 2025 11:02 GMT, 11 min28 Aug 2025 22:34 GMT, 48 min2 spills, 0.9 h, 3 Sep to 4 Sep3 spills, 1.8 h, 8 Sep to 8 Sep3 spills, 0.5 h, 9 Sep to 10 Sep2 spills, 0.3 h, 20 Sep to 20 Sep27 Sep 2025 20:30 GMT, 21 min3 spills, 1.6 h, 19 Oct to 19 Oct20 Oct 2025 07:12 GMT, 10 min30 Oct 2025 20:59 GMT, 6 min14 spills, 6.9 h, 4 Nov to 5 Nov2 spills, 0.8 h, 7 Nov to 7 Nov6 spills, 3.4 h, 9 Nov to 10 Nov17 spills, 95.9 h, 11 Nov to 15 Nov2 spills, 0.7 h, 22 Nov to 22 Nov24 Nov 2025 09:51 GMT, 19 min2 spills, 0.5 h, 29 Nov to 29 Nov9 spills, 32.3 h, 30 Nov to 3 Dec4 spills, 1.4 h, 4 Dec to 4 Dec5 spills, 154.2 h, 5 Dec to 12 Dec9 spills, 134.4 h, 15 Dec to 20 Dec

Hours spilling by month, 2025

0100200300400Jan 2025: 133 hours spillingJanFeb 2025: 51 hours spillingFebMar 2025: 0.0 hours spillingMarApr 2025: 3.6 hours spillingAprMay 2025: 0.0 hours spillingMayJun 2025: 2.3 hours spillingJunJul 2025: 0.6 hours spillingJulAug 2025: 1.0 hours spillingAugSep 2025: 3.9 hours spillingSepOct 2025: 1.8 hours spillingOctNov 2025: 109 hours spillingNovDec 2025: 322 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
5 Dec 2025, 12:52Harrowbarrow WwTW6.3 days
15 Dec 2025, 05:18Harrowbarrow WwTW5.4 days
5 Jan 2025, 22:02Harrowbarrow WwTW3.1 days
26 Jan 2025, 18:31Harrowbarrow WwTW1.8 days
23 Feb 2025, 17:35Harrowbarrow WwTW1.8 days

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate10,762 m³range 4,287 - 27,019 m³
In litres10.8 millionrange 4.3 million - 27.0 million L
Olympic swimming pools4.3at 2,500 m³ each
Organic load, as people's raw sewage16,143person-days of untreated BOD

Assumed spill rate while spilling: 1.9 - 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 171 kg969 kg5,404 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 450 kg4,574 kg19,481 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 8.1 kg68 kg251 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3-9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 5.1 kg28 kg146 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 428.7 billion organisms10.8 trillion organisms270.2 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Harrowbarrow WwTW

Inlet overflow at sewage works · discharges to (S)Unnamed Trib River Tamar

Spills 2025
68 (628 hours) · down 14% on 2024
Spills 2024
79 (356 hours)
Long-term average
60.3 spills a year (monitored since 2019)
Monitor uptime
99% of the year
High-spill reason (company)
Not asset maintenance - hydraulic capacity
Investigation
UWWTR investigation completed, Operational investigation completed
Improvement
Operational improvement ongoing
WFD catchment
Cotehele Stream (GB108047004070)
Outlet location
SX40296973 (OS grid reference) · View on Apple Maps
EA ID / permit
SBB01381 · NRA-SW-0227 · company name: HARROW BARROW STW_SO_CALLINGTON

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024-25 [EA]. Infiltration of groundwater into sewers is taken as 0-40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies - environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 - per capita consumption
  3. HBF: Foul sewer design - historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 - CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All South West Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.