High Bickington sewage works: storm overflow spills 2025

High Bickington sewage treatment works, run by South West Water, has 1 monitored storm overflow discharging to Tributary of Langham Lake(S). In 2025 it recorded 173 spills totalling 1,912 hours, against 233 spills and 2,657 hours in 2024. By hours spilling, it ranks 42 of 334 South West Water works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecHigh Bickington STW74 spills, 42.3 h, 1 Jan to 4 Jan127 spills, 84.5 h, 6 Jan to 13 Jan2 spills, 0.6 h, 15 Jan to 15 Jan97 spills, 49.9 h, 23 Jan to 28 Jan124 spills, 81.2 h, 29 Jan to 5 Feb21 spills, 5.5 h, 14 Feb to 15 Feb7 spills, 1.3 h, 19 Feb to 20 Feb129 spills, 129.6 h, 21 Feb to 3 Mar11 Mar 2025 07:47 GMT, 8 min13 Mar 2025 19:49 GMT, 8 min19 Mar 2025 07:35 GMT, 6 min198 spills, 108.1 h, 15 Apr to 27 Apr28 Apr 2025 06:22 GMT, 6 min2 spills, 0.2 h, 29 Apr to 29 Apr20 May 2025 09:05 GMT, 13 min21 May 2025 08:31 GMT, 28 min4 spills, 3.6 h, 27 May to 28 May30 May 2025 09:07 GMT, 16 min3 spills, 0.8 h, 3 Jun to 3 Jun6 Jun 2025 01:48 GMT, 34 min3 spills, 2.2 h, 7 Jun to 7 Jun10 Jun 2025 06:55 GMT, 9 min19 spills, 52.8 h, 12 Jun to 15 Jun24 Jun 2025 06:00 GMT, 16 min26 Jun 2025 06:30 GMT, 22 min5 Jul 2025 11:50 GMT, 10 min2 spills, 0.2 h, 21 Jul to 21 Jul5 spills, 3 h, 28 Aug to 29 Aug4 spills, 1.7 h, 30 Aug to 30 Aug4 spills, 0.9 h, 1 Sep to 1 Sep19 spills, 6.3 h, 2 Sep to 4 Sep4 spills, 4 h, 7 Sep to 7 Sep2 spills, 0.9 h, 8 Sep to 8 Sep9 Sep 2025 16:17 GMT, 27 min29 spills, 15.4 h, 10 Sep to 13 Sep9 spills, 33.7 h, 14 Sep to 16 Sep20 spills, 87.1 h, 17 Sep to 22 Sep27 Sep 2025 22:17 GMT, 19 min6 spills, 14.5 h, 3 Oct to 4 Oct63 spills, 398.7 h, 19 Oct to 8 Nov36 spills, 191.1 h, 9 Nov to 20 Nov51 spills, 258.6 h, 22 Nov to 5 Dec3 spills, 34.9 h, 6 Dec to 9 Dec27 spills, 295 h, 9 Dec to 25 Dec26 Dec 2025 10:38 GMT, 6 min29 Dec 2025 10:17 GMT, 16 min

Hours spilling by month, 2025

0200400600Jan 2025: 239 hours spillingJanFeb 2025: 154 hours spillingFebMar 2025: 2.4 hours spillingMarApr 2025: 108 hours spillingAprMay 2025: 4.6 hours spillingMayJun 2025: 57 hours spillingJunJul 2025: 0.4 hours spillingJulAug 2025: 4.7 hours spillingAugSep 2025: 149 hours spillingSepOct 2025: 267 hours spillingOctNov 2025: 501 hours spillingNovDec 2025: 425 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
19 Dec 2025, 01:57High Bickington STW4.9 days
24 Oct 2025, 09:50High Bickington STW3.7 days
31 Oct 2025, 22:06High Bickington STW3.3 days
15 Nov 2025, 04:21High Bickington STW2.3 days
9 Dec 2025, 22:01High Bickington STW2.2 days

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate32,761 m³range 13,049 - 82,248 m³
In litres32.8 millionrange 13.0 million - 82.2 million L
Olympic swimming pools13at 2,500 m³ each
Organic load, as people's raw sewage49,142person-days of untreated BOD

Assumed spill rate while spilling: 1.9 - 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 522 kg2,948 kg16,450 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 1,370 kg13,923 kg59,301 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 25 kg206 kg765 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3-9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 16 kg85 kg444 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 1.3 trillion organisms32.8 trillion organisms822.5 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

High Bickington STW

Inlet overflow at sewage works · discharges to Tributary of Langham Lake(S)

Spills 2025
173 (1,912 hours) · down 26% on 2024
Spills 2024
233 (2,657 hours)
Long-term average
186.6 spills a year (monitored since 2021)
Monitor uptime
100% of the year
High-spill reason (company)
Not asset maintenance - hydraulic capacity
Investigation
UWWTR investigation ongoing, Operational investigation completed
Improvement
Operational improvement ongoing
WFD catchment
Langham Lake (GB108050014460)
Outlet location
SS59162017 (OS grid reference) · View on Apple Maps
EA ID / permit
SBB00568 · 202194/CS/01 · company name: HIGH BICKINGTON STW_SO_HIGH BICKINGTON

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024-25 [EA]. Infiltration of groundwater into sewers is taken as 0-40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies - environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 - per capita consumption
  3. HBF: Foul sewer design - historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 - CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All South West Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.