Storm overflow register · South West Water

Payhembury sewage works: storm overflow spills 2025

Payhembury sewage treatment works, run by South West Water, has 1 monitored storm overflow discharging to Little Mere River. In 2025 it recorded 119 spills totalling 2,058 hours, against 279 spills and 5,373 hours in 2024. By hours spilling, it ranks 33 of 334 South West Water works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecPayhembury STW1 Jan 2025 11:51 GMT, 3.6 h203 spills, 1264 h, 4 Jan to 11 Mar37 spills, 395 h, 12 Mar to 2 Apr2 spills, 0.4 h, 4 Apr to 4 Apr9 Sep 2025 21:57 GMT, 4.9 h9 Nov 2025 16:23 GMT, 7.2 h2 spills, 20 h, 11 Nov to 12 Nov2 spills, 29.2 h, 13 Nov to 15 Nov22 Nov 2025 13:20 GMT, 7.8 h3 spills, 28.1 h, 1 Dec to 2 Dec6 spills, 104 h, 5 Dec to 11 Dec12 Dec 2025 19:11 GMT, 2.5 h5 spills, 189.9 h, 15 Dec to 24 Dec29 Dec 2025 15:06 GMT, 90 min

Hours spilling by month, 2025

0200400600800Jan 2025: 407 hours spillingJanFeb 2025: 651 hours spillingFebMar 2025: 589 hours spillingMarApr 2025: 15 hours spillingAprMay 2025: 0.0 hours spillingMayJun 2025: 0.0 hours spillingJunJul 2025: 0.0 hours spillingJulAug 2025: 0.0 hours spillingAugSep 2025: 4.9 hours spillingSepOct 2025: 0.0 hours spillingOctNov 2025: 64 hours spillingNovDec 2025: 326 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
19 Feb 2025, 02:56Payhembury STW6.9 days
19 Mar 2025, 06:34Payhembury STW5.3 days
5 Mar 2025, 06:46Payhembury STW5.1 days
13 Feb 2025, 00:39Payhembury STW4.1 days
26 Jan 2025, 05:03Payhembury STW4.0 days

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate35,266 m³range 14,047 - 88,537 m³
In litres35.3 millionrange 14.0 million - 88.5 million L
Olympic swimming pools14at 2,500 m³ each
Organic load, as people's raw sewage52,899person-days of untreated BOD

Assumed spill rate while spilling: 1.9 - 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 562 kg3,174 kg17,707 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 1,475 kg14,988 kg63,835 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 27 kg222 kg823 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3-9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 17 kg92 kg478 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 1.4 trillion organisms35.3 trillion organisms885.4 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Payhembury STW

Storm tank at sewage works · discharges to Little Mere River

Spills 2025
119 (2,058 hours) · down 57% on 2024
Spills 2024
279 (5,373 hours)
Long-term average
140.3 spills a year (monitored since 2019)
Monitor uptime
80% of the year · Capital / maintenance works affect EDM operation
High-spill reason (company)
Not asset maintenance - hydraulic capacity
Investigation
UWWTR investigation completed, Operational investigation completed
Improvement
UWWTR improvement completed, Operational improvement completed
WFD catchment
Tale (GB108045009200)
Outlet location
ST08720124 (OS grid reference) · View on Apple Maps
EA ID / permit
SBB01396 · SWWA 2498 · company name: PAYHEMBURY STW_SSO_PAYHEMBURY

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024-25 [EA]. Infiltration of groundwater into sewers is taken as 0-40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies - environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 - per capita consumption
  3. HBF: Foul sewer design - historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 - CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All South West Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.