Storm overflow register · South West Water

Totnes sewage works: storm overflow spills 2025

Totnes sewage treatment works, run by South West Water, has 1 monitored storm overflow discharging to Dart Estuary(E). In 2025 it recorded 123 spills totalling 698 hours, against 177 spills and 1,213 hours in 2024. By hours spilling, it ranks 147 of 334 South West Water works, where 1 spilled longest.

Works size: 10,600 population equivalent (TOTNES STW, UWWTD 2018). Used for the spill volume estimate.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecTotnes STW337 spills, 95.8 h, 5 Jan to 13 Jan9 spills, 0.4 h, 16 Jan to 18 Jan2 spills, 0.1 h, 20 Jan to 20 Jan293 spills, 119.1 h, 21 Jan to 2 Feb14 Feb 2025 15:50 GMT, 1 min67 spills, 13.1 h, 20 Feb to 22 Feb161 spills, 53.1 h, 23 Feb to 1 Mar7 spills, 0.9 h, 16 Apr to 16 Apr32 spills, 18.9 h, 18 Apr to 19 Apr25 Apr 2025 14:53 GMT, 2 min9 May 2025 13:40 GMT, 4 min11 May 2025 11:58 GMT, 2 min28 May 2025 08:11 GMT, 3 min5 Jun 2025 08:44 GMT, 4 min12 Jun 2025 20:01 GMT, 10 min13 Jun 2025 19:04 GMT, 2 min20 Jul 2025 07:16 GMT, 5 min14 Aug 2025 02:19 GMT, 4 min30 Aug 2025 17:38 GMT, 7 min3 spills, 1.2 h, 31 Aug to 31 Aug31 spills, 8.4 h, 3 Sep to 4 Sep9 Sep 2025 15:37 GMT, 5 min40 spills, 8.8 h, 10 Sep to 11 Sep45 spills, 4.2 h, 13 Sep to 15 Sep66 spills, 15.5 h, 17 Sep to 19 Sep18 spills, 1 h, 3 Oct to 6 Oct35 spills, 8.1 h, 19 Oct to 21 Oct36 spills, 6.8 h, 22 Oct to 24 Oct30 Oct 2025 21:01 GMT, 3 min1 Nov 2025 13:19 GMT, 1 min2 Nov 2025 13:46 GMT, 5 min359 spills, 89.7 h, 5 Nov to 19 Nov22 Nov 2025 08:20 GMT, 4 min26 spills, 2.2 h, 23 Nov to 25 Nov371 spills, 146.9 h, 28 Nov to 13 Dec301 spills, 103.8 h, 15 Dec to 22 Dec3 spills, 0.4 h, 23 Dec to 23 Dec

Estimated spill volume by month, 2025

Hours spilling each month × the estimated spill rate for a works of this size. The bars are central estimates and the whiskers show the low-high range. Method.

050k100k150kJan 2025: 212 h spilling ≈ 38,541 m³ (range 15,352-96,758 m³)JanFeb 2025: 69 h spilling ≈ 12,478 m³ (range 4,970-31,326 m³)FebMar 2025: 0.5 h spilling ≈ 91 m³ (range 36-228 m³)MarApr 2025: 20 h spilling ≈ 3,596 m³ (range 1,432-9,028 m³)AprMay 2025: 0.2 h spilling ≈ 36 m³ (range 14-91 m³)MayJun 2025: 0.3 h spilling ≈ 54 m³ (range 22-137 m³)JunJul 2025: 0.1 h spilling ≈ 18 m³ (range 7.2-46 m³)JulAug 2025: 1.4 h spilling ≈ 254 m³ (range 101-638 m³)AugSep 2025: 37 h spilling ≈ 6,702 m³ (range 2,670-16,826 m³)SepOct 2025: 16 h spilling ≈ 2,888 m³ (range 1,150-7,250 m³)OctNov 2025: 96 h spilling ≈ 17,472 m³ (range 6,960-43,865 m³)NovDec 2025: 247 h spilling ≈ 44,843 m³ (range 17,862-112,581 m³)Dec
Cubic metres (m³), estimate. Hours are measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDurationEstimated volume
27 Jan 2025, 15:04Totnes STW8.3 h597 - 3,762 m³
19 Dec 2025, 03:27Totnes STW8.2 h593 - 3,739 m³
26 Jan 2025, 10:11Totnes STW8.1 h584 - 3,678 m³
26 Jan 2025, 18:45Totnes STW7.5 h541 - 3,412 m³
28 Jan 2025, 01:55Totnes STW5.6 h402 - 2,531 m³

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

Volume, central estimate126,829 m³range 50,519 - 318,409 m³
In litres126.8 millionrange 50.5 million - 318.4 million L
Olympic swimming pools51at 2,500 m³ each
Organic load, as people's raw sewage190,243person-days of untreated BOD

Assumed spill rate while spilling: 20.1 - 126.7 L/s (central 50.5 L/s), from a dry-weather flow of 20.1 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 2,021 kg11,415 kg63,682 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 5,304 kg53,902 kg229,573 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 96 kg799 kg2,961 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3-9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 61 kg330 kg1,719 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 5.1 trillion organisms126.8 trillion organisms3.2 × 10¹⁵ organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Totnes STW

Inlet overflow at sewage works · discharges to Dart Estuary(E)

Spills 2025
123 (698 hours) · down 31% on 2024
Spills 2024
177 (1,213 hours)
Long-term average
97.6 spills a year
Monitor uptime
100% of the year
High-spill reason (company)
Performance - SW Infiltration
Investigation
Operational investigation completed
Improvement
Env Act (SODRP) improvement ongoing
Bathing water
Steamer Quay, Dart Estuary
Shellfish water
Dart
WFD catchment
Not part of a WFD catchment
Outlet location
SX80716101 (OS grid reference) · View on Apple Maps
EA ID / permit
SBB01264 · 203080 · company name: TOTNES STW_SSO_TOTNES

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024-25 [EA]. Infiltration of groundwater into sewers is taken as 0-40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies - environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 - per capita consumption
  3. HBF: Foul sewer design - historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 - CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All South West Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.