Storm overflow register · South West Water

Weare Giffard sewage works: storm overflow spills 2025

Weare Giffard sewage treatment works, run by South West Water, has 1 monitored storm overflow discharging to River Torridge. In 2025 it recorded 115 spills totalling 1,341 hours, against 167 spills and 2,745 hours in 2024. By hours spilling, it ranks 78 of 334 South West Water works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecWeare Giffard WwTW13 spills, 3.7 h, 1 Jan to 3 Jan51 spills, 149.7 h, 4 Jan to 12 Jan27 spills, 24.2 h, 24 Jan to 27 Jan117 spills, 62.5 h, 2 Feb to 10 Feb11 Feb 2025 12:04 GMT, 20 min14 Feb 2025 11:50 GMT, 17 min2 spills, 0.7 h, 15 Feb to 15 Feb104 spills, 174 h, 21 Feb to 4 Mar43 spills, 103.8 h, 15 Apr to 21 Apr22 Apr 2025 22:18 GMT, 37 min2 spills, 1.9 h, 12 Jun to 12 Jun1 Sep 2025 07:58 GMT, 20 min4 spills, 1.3 h, 13 Sep to 13 Sep44 spills, 18.6 h, 14 Sep to 17 Sep3 spills, 1.1 h, 19 Sep to 19 Sep20 Sep 2025 15:09 GMT, 23 min9 spills, 3.4 h, 25 Oct to 25 Oct26 Oct 2025 19:01 GMT, 16 min29 Oct 2025 10:30 GMT, 19 min30 Oct 2025 21:53 GMT, 15 min117 spills, 34.6 h, 31 Oct to 8 Nov57 spills, 153.8 h, 11 Nov to 20 Nov189 spills, 603.8 h, 24 Nov to 25 Dec3 spills, 1 h, 30 Dec to 31 Dec

Hours spilling by month, 2025

0200400600Jan 2025: 178 hours spillingJanFeb 2025: 200 hours spillingFebMar 2025: 38 hours spillingMarApr 2025: 104 hours spillingAprMay 2025: 0.0 hours spillingMayJun 2025: 1.9 hours spillingJunJul 2025: 0.0 hours spillingJulAug 2025: 0.0 hours spillingAugSep 2025: 22 hours spillingSepOct 2025: 4.5 hours spillingOctNov 2025: 273 hours spillingNovDec 2025: 520 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
29 Nov 2025, 08:53Weare Giffard WwTW14.4 days
15 Dec 2025, 06:30Weare Giffard WwTW6.3 days
12 Nov 2025, 03:31Weare Giffard WwTW5.3 days
5 Jan 2025, 03:05Weare Giffard WwTW4.8 days
24 Feb 2025, 02:31Weare Giffard WwTW3.9 days

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate22,970 m³range 9,150 - 57,668 m³
In litres23.0 millionrange 9.1 million - 57.7 million L
Olympic swimming pools9.2at 2,500 m³ each
Organic load, as people's raw sewage34,456person-days of untreated BOD

Assumed spill rate while spilling: 1.9 - 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 366 kg2,067 kg11,534 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 961 kg9,762 kg41,579 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 17 kg145 kg536 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3-9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 11 kg60 kg311 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 915.0 billion organisms23.0 trillion organisms576.7 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Weare Giffard WwTW

Inlet overflow at sewage works · discharges to River Torridge

Spills 2025
115 (1,341 hours) · down 31% on 2024
Spills 2024
167 (2,745 hours)
Long-term average
169.1 spills a year (monitored since 2017)
Monitor uptime
100% of the year
High-spill reason (company)
Not Applicable - Ongoing investigation
Investigation
Env Act (SODRP) investigation ongoing, Operational investigation completed
Improvement
No improvement action in reporting period
Shellfish water
Taw-Torridge Estuary
WFD catchment
Not part of a WFD catchment
Outlet location
SS47182204 (OS grid reference) · View on Apple Maps
EA ID / permit
SBB01324 · 202222 · company name: WEARE GIFFARD STW_SO_WEARE GIFFARD

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024-25 [EA]. Infiltration of groundwater into sewers is taken as 0-40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies - environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 - per capita consumption
  3. HBF: Foul sewer design - historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 - CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All South West Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.