Storm overflow register · Southern Water

Catsfield sewage works: storm overflow spills 2025

Catsfield sewage treatment works, run by Southern Water, has 1 monitored storm overflow discharging to Trib of the River Pevensey. In 2025 it recorded 33 spills totalling 123 hours, against 74 spills and 743 hours in 2024. By hours spilling, it ranks 137 of 215 Southern Water works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecCatsfield WwTW1 Jan 2025 14:53 GMT, 29 min1 Jan 2025 17:47 GMT, 3.5 h4 Jan 2025 23:22 GMT, 20.2 h5 Jan 2025 19:48 GMT, 5.3 h24 Jan 2025 06:06 GMT, 2.8 h24 Jan 2025 10:01 GMT, 20 min26 Jan 2025 23:23 GMT, 112 min31 Jan 2025 11:23 GMT, 2.7 h22 Feb 2025 01:12 GMT, 3 h24 Feb 2025 08:07 GMT, 118 min26 Feb 2025 13:17 GMT, 22 min15 Apr 2025 02:12 GMT, 25 min23 Apr 2025 06:30 GMT, 78 min21 May 2025 12:58 GMT, 18 min6 Jul 2025 16:27 GMT, 52 min18 Jul 2025 23:27 GMT, 15 min19 Jul 2025 10:56 GMT, 2.5 h21 Jul 2025 02:29 GMT, 21.5 h23 Jul 2025 10:40 GMT, 58 min29 Aug 2025 08:11 GMT, 26 min3 Sep 2025 03:14 GMT, 22 min3 Sep 2025 07:42 GMT, 48 min3 Sep 2025 12:25 GMT, 34 min13 Sep 2025 05:14 GMT, 6.5 h20 Oct 2025 15:42 GMT, 50 min20 Oct 2025 18:38 GMT, 96 min22 Oct 2025 20:39 GMT, 7.3 h23 Oct 2025 04:55 GMT, 7.5 h29 Oct 2025 16:10 GMT, 22 min1 Nov 2025 06:22 GMT, 3 h1 Nov 2025 16:25 GMT, 21 min1 Nov 2025 18:27 GMT, 23 min2 Nov 2025 07:33 GMT, 50 min2 Nov 2025 08:25 GMT, 3.9 h10 Nov 2025 13:01 GMT, 7.7 h29 Nov 2025 13:15 GMT, 28 min6 Dec 2025 04:07 GMT, 3.7 h7 Dec 2025 12:59 GMT, 5.6 h

Hours spilling by month, 2025

010203040Jan 2025: 37 hours spillingJanFeb 2025: 5.3 hours spillingFebMar 2025: 0.0 hours spillingMarApr 2025: 1.7 hours spillingAprMay 2025: 0.3 hours spillingMayJun 2025: 0.0 hours spillingJunJul 2025: 26 hours spillingJulAug 2025: 0.4 hours spillingAugSep 2025: 8.2 hours spillingSepOct 2025: 18 hours spillingOctNov 2025: 17 hours spillingNovDec 2025: 9.4 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
21 Jul 2025, 02:29Catsfield WwTW21.5 h
4 Jan 2025, 23:22Catsfield WwTW20.2 h
10 Nov 2025, 13:01Catsfield WwTW7.7 h
23 Oct 2025, 04:55Catsfield WwTW7.5 h
22 Oct 2025, 20:39Catsfield WwTW7.3 h

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate2,106 m³range 839 – 5,287 m³
In litres2.1 millionrange 838,793 – 5.3 million L
Olympic swimming pools0.8at 2,500 m³ each
Organic load, as people's raw sewage3,159person-days of untreated BOD

Assumed spill rate while spilling: 1.9 – 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 34 kg190 kg1,057 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 88 kg895 kg3,812 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 1.6 kg13 kg49 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3–9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 1.0 kg5.5 kg29 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 83.9 billion organisms2.1 trillion organisms52.9 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Catsfield WwTW

Inlet overflow at sewage works · discharges to Trib of the River Pevensey

Spills 2025
33 (123 hours) · down 55% on 2024
Spills 2024
74 (743 hours)
Long-term average
47.2 spills a year (monitored since 2019)
Monitor uptime
96% of the year
High-spill reason (company)
Not asset maintenance - Hydraulic capacity
Investigation
UWWTR investigation ongoing
Improvement
No improvement action in reporting period
WFD catchment
Watermill Stream (GB107041012540)
Outlet location
TQ7161013380 (OS grid reference) · View on Apple Maps
EA ID / permit
SWS00148 · W00336 · company name: CATSFIELD CSO - 115979

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024–25 [EA]. Infiltration of groundwater into sewers is taken as 0–40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies – environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 – per capita consumption
  3. HBF: Foul sewer design – historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 – CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Southern Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.