Storm overflow register · Southern Water

Northchapel sewage works: storm overflow spills 2025

Northchapel sewage treatment works, run by Southern Water, has 1 monitored storm overflow discharging to River Kird. In 2025 it recorded 40 spills totalling 471 hours, against 83 spills and 1,105 hours in 2024. By hours spilling, it ranks 51 of 215 Southern Water works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecNorthchapel WwTW1 Jan 2025 17:20 GMT, 7.3 h2 Jan 2025 00:49 GMT, 13 min2 Jan 2025 01:24 GMT, 11 min5 Jan 2025 00:52 GMT, 19.6 h5 Jan 2025 20:29 GMT, 19 h6 Jan 2025 15:32 GMT, 6 min6 Jan 2025 15:39 GMT, 6.9 h6 Jan 2025 22:33 GMT, 25 min6 Jan 2025 23:00 GMT, 8 min6 Jan 2025 23:11 GMT, 8 min6 Jan 2025 23:26 GMT, 112 min7 Jan 2025 01:27 GMT, 23 min7 Jan 2025 02:08 GMT, 24 min7 Jan 2025 03:38 GMT, 10 min7 Jan 2025 06:43 GMT, 21 min7 Jan 2025 07:09 GMT, 97 min7 Jan 2025 08:53 GMT, 111 min7 Jan 2025 10:48 GMT, 13 min7 Jan 2025 11:32 GMT, 14 min7 Jan 2025 12:57 GMT, 13 min7 Jan 2025 18:47 GMT, 16 min7 Jan 2025 20:17 GMT, 12 min8 Jan 2025 03:34 GMT, 54 min8 Jan 2025 18:53 GMT, 22 min9 Jan 2025 01:13 GMT, 57 min24 Jan 2025 07:30 GMT, 13.2 h26 Jan 2025 11:44 GMT, 10.7 h26 Jan 2025 22:24 GMT, 10.8 h27 Jan 2025 09:13 GMT, 92 min27 Jan 2025 10:47 GMT, 10 min27 Jan 2025 11:05 GMT, 3 min27 Jan 2025 11:12 GMT, 2 min27 Jan 2025 11:24 GMT, 3 min27 Jan 2025 11:31 GMT, 2 min27 Jan 2025 11:41 GMT, 14 min27 Jan 2025 12:01 GMT, 7 min27 Jan 2025 12:08 GMT, 3 min27 Jan 2025 12:20 GMT, 15 min27 Jan 2025 12:40 GMT, 14 min27 Jan 2025 12:58 GMT, 16 min27 Jan 2025 13:16 GMT, 5 min27 Jan 2025 13:22 GMT, 4 min27 Jan 2025 13:27 GMT, 22.1 h28 Jan 2025 11:36 GMT, 4.9 h28 Jan 2025 16:37 GMT, 29 min28 Jan 2025 17:11 GMT, 27 min28 Jan 2025 17:46 GMT, 3.5 h28 Jan 2025 21:20 GMT, 22 min28 Jan 2025 22:07 GMT, 98 min28 Jan 2025 23:47 GMT, 89 min29 Jan 2025 07:57 GMT, 12 min31 Jan 2025 06:33 GMT, 118 min31 Jan 2025 08:32 GMT, 16 min31 Jan 2025 08:49 GMT, 7 min31 Jan 2025 08:58 GMT, 2.3 h31 Jan 2025 11:24 GMT, 13 min31 Jan 2025 11:48 GMT, 4 min31 Jan 2025 13:02 GMT, 14 min31 Jan 2025 13:39 GMT, 15 min31 Jan 2025 18:59 GMT, 60 min1 Feb 2025 19:40 GMT, 29 min21 Feb 2025 20:20 GMT, 149.4 h31 Jul 2025 17:13 GMT, 7.4 h3 Sep 2025 12:20 GMT, 2.9 h3 Sep 2025 17:24 GMT, 2.3 h20 Oct 2025 07:28 GMT, 13 h22 Oct 2025 22:32 GMT, 10.9 h23 Oct 2025 17:31 GMT, 2 min23 Oct 2025 18:15 GMT, 4 min23 Oct 2025 18:21 GMT, 4 min23 Oct 2025 18:32 GMT, 3 min23 Oct 2025 18:45 GMT, 4 min23 Oct 2025 18:58 GMT, 4 min23 Oct 2025 19:18 GMT, 3 min23 Oct 2025 19:33 GMT, 2 min31 Oct 2025 20:11 GMT, 23.5 h2 Dec 2025 20:52 GMT, 13.3 h3 Dec 2025 17:31 GMT, 75 min4 Dec 2025 07:27 GMT, 12.4 h5 Dec 2025 17:43 GMT, 21.4 h7 Dec 2025 07:10 GMT, 16 h9 Dec 2025 03:20 GMT, 19.8 h18 Dec 2025 12:26 GMT, 33.7 h

Hours spilling by month, 2025

050100150Jan 2025: 143 hours spillingJanFeb 2025: 150 hours spillingFebMar 2025: 0.0 hours spillingMarApr 2025: 0.0 hours spillingAprMay 2025: 0.0 hours spillingMayJun 2025: 0.0 hours spillingJunJul 2025: 6.8 hours spillingJulAug 2025: 0.6 hours spillingAugSep 2025: 5.2 hours spillingSepOct 2025: 28 hours spillingOctNov 2025: 20 hours spillingNovDec 2025: 118 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
21 Feb 2025, 20:20Northchapel WwTW6.2 days
18 Dec 2025, 12:26Northchapel WwTW1.4 days
31 Oct 2025, 20:11Northchapel WwTW23.5 h
27 Jan 2025, 13:27Northchapel WwTW22.1 h
5 Dec 2025, 17:43Northchapel WwTW21.4 h

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate8,074 m³range 3,216 – 20,269 m³
In litres8.1 millionrange 3.2 million – 20.3 million L
Olympic swimming pools3.2at 2,500 m³ each
Organic load, as people's raw sewage12,111person-days of untreated BOD

Assumed spill rate while spilling: 1.9 – 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 129 kg727 kg4,054 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 338 kg3,431 kg14,614 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 6.1 kg51 kg189 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3–9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 3.9 kg21 kg109 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 321.6 billion organisms8.1 trillion organisms202.7 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Northchapel WwTW

Storm tank at sewage works · discharges to River Kird

Spills 2025
40 (471 hours) · down 52% on 2024
Spills 2024
83 (1,105 hours)
Long-term average
48.6 spills a year (monitored since 2016)
Monitor uptime
100% of the year
High-spill reason (company)
Performance - GW inundation
Investigation
Env Act (SODRP) investigation ongoing, UWWTR investigation ongoing
Improvement
No improvement action in reporting period
WFD catchment
R. Kird (GB107041012300)
Outlet location
SU9525029030 (OS grid reference) · View on Apple Maps
EA ID / permit
SWS00617 · W00364 · company name: NORTHCHAPEL SSO - 115788

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024–25 [EA]. Infiltration of groundwater into sewers is taken as 0–40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies – environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 – per capita consumption
  3. HBF: Foul sewer design – historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 – CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Southern Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.