Storm overflow register · Southern Water

Summer Lane Pagham sewage works: storm overflow spills 2025

Summer Lane Pagham sewage treatment works, run by Southern Water, has 1 monitored storm overflow discharging to Pagham Rife. In 2025 it recorded 22 spills totalling 358 hours, against 72 spills and 1,195 hours in 2024. By hours spilling, it ranks 75 of 215 Southern Water works, where 1 spilled longest.

Works size: 9,962 population equivalent (PAGHAM STW, UWWTD 2018). Used for the spill volume estimate.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecSummer Lane Pagham…1 Jan 2025 20:24 GMT, 63.6 h5 Jan 2025 03:41 GMT, 70.1 h8 Jan 2025 09:31 GMT, 37.8 h26 Jan 2025 20:34 GMT, 50.6 h29 Jan 2025 17:50 GMT, 10.6 h30 Jan 2025 09:00 GMT, 4.7 h31 Jan 2025 08:31 GMT, 18 h1 Feb 2025 09:34 GMT, 7.5 h1 Feb 2025 19:09 GMT, 69 min22 Feb 2025 05:50 GMT, 18.8 h24 Feb 2025 01:39 GMT, 51.3 h26 Feb 2025 08:05 GMT, 18.4 h27 Feb 2025 08:21 GMT, 5.6 h

Estimated spill volume by month, 2025

Hours spilling each month × the estimated spill rate for a works of this size. The bars are central estimates and the whiskers show the low–high range. Method.

050k100k150kJan 2025: 253 h spilling ≈ 43,134 m³ (range 17,181–108,290 m³)JanFeb 2025: 105 h spilling ≈ 17,974 m³ (range 7,159–45,124 m³)FebMar 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)MarApr 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)AprMay 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)MayJun 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)JunJul 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)JulAug 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)AugSep 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)SepOct 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)OctNov 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)NovDec 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)Dec
Cubic metres (m³), estimate. Hours are measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDurationEstimated volume
5 Jan 2025, 03:41Summer Lane Pagham WwTW2.9 days4,765 – 30,033 m³
1 Jan 2025, 20:24Summer Lane Pagham WwTW2.6 days4,323 – 27,247 m³
24 Feb 2025, 01:39Summer Lane Pagham WwTW2.1 days3,485 – 21,962 m³
26 Jan 2025, 20:34Summer Lane Pagham WwTW2.1 days3,440 – 21,684 m³
8 Jan 2025, 09:31Summer Lane Pagham WwTW1.6 days2,567 – 16,177 m³

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

Volume, central estimate61,108 m³range 24,341 – 153,414 m³
In litres61.1 millionrange 24.3 million – 153.4 million L
Olympic swimming pools24at 2,500 m³ each
Organic load, as people's raw sewage91,662person-days of untreated BOD

Assumed spill rate while spilling: 18.9 – 119.0 L/s (central 47.4 L/s), from a dry-weather flow of 18.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 974 kg5,500 kg30,683 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 2,556 kg25,971 kg110,612 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 46 kg385 kg1,427 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3–9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 29 kg159 kg828 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 2.4 trillion organisms61.1 trillion organisms1.5 × 10¹⁵ organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Summer Lane Pagham WwTW

Storm tank at sewage works · discharges to Pagham Rife

Spills 2025
22 (358 hours) · down 69% on 2024
Spills 2024
72 (1,195 hours)
Long-term average
50.4 spills a year (monitored since 2016)
Monitor uptime
99% of the year
Investigation
Env Act (SODRP) investigation ongoing, UWWTR investigation ongoing
Improvement
No improvement action in reporting period
Bathing water
Pagham
WFD catchment
Pagham Harbour (GB107041012880)
Outlet location
SZ8827098950 (OS grid reference) · View on Apple Maps
EA ID / permit
SWS00640 · A01192 · company name: SUMMER LANE PAGHAM SSO - 115443

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024–25 [EA]. Infiltration of groundwater into sewers is taken as 0–40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies – environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 – per capita consumption
  3. HBF: Foul sewer design – historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 – CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Southern Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.