Storm overflow register · Southern Water

West Hoathly S T W sewage works: storm overflow spills 2025

West Hoathly S T W sewage treatment works, run by Southern Water, has 1 monitored storm overflow discharging to The Coombe Brook. In 2025 it recorded 44 spills totalling 484 hours, against 54 spills and 503 hours in 2024. By hours spilling, it ranks 50 of 215 Southern Water works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecWest Hoathly S.T.W.1 Jan 2025 14:05 GMT, 14.4 h2 Jan 2025 04:44 GMT, 7 min2 Jan 2025 05:34 GMT, 6 min2 Jan 2025 09:07 GMT, 2 min2 Jan 2025 09:26 GMT, 2 min2 Jan 2025 10:51 GMT, 2 min5 Jan 2025 01:39 GMT, 46.2 h7 Jan 2025 00:08 GMT, 3 min7 Jan 2025 10:08 GMT, 2 min7 Jan 2025 11:23 GMT, 2 min24 Jan 2025 07:15 GMT, 5.2 h24 Jan 2025 12:42 GMT, 45 min24 Jan 2025 13:52 GMT, 2 min24 Jan 2025 15:23 GMT, 2 min26 Jan 2025 14:13 GMT, 19.6 h27 Jan 2025 10:11 GMT, 112 min27 Jan 2025 12:32 GMT, 5 min27 Jan 2025 13:05 GMT, 2 min27 Jan 2025 13:25 GMT, 2 min27 Jan 2025 13:43 GMT, 2 min27 Jan 2025 20:21 GMT, 2 min28 Jan 2025 07:42 GMT, 2 min28 Jan 2025 08:43 GMT, 70 min28 Jan 2025 10:15 GMT, 4 min28 Jan 2025 10:43 GMT, 15 min28 Jan 2025 11:17 GMT, 6 min22 Feb 2025 01:44 GMT, 10.8 h24 Feb 2025 02:29 GMT, 20.3 h26 Feb 2025 12:20 GMT, 10.3 h19 Jul 2025 10:58 GMT, 46 min29 Aug 2025 07:18 GMT, 2.2 h3 Sep 2025 03:22 GMT, 3.7 h3 Sep 2025 07:07 GMT, 2 min3 Sep 2025 07:17 GMT, 7 min3 Sep 2025 07:38 GMT, 3 min3 Sep 2025 07:54 GMT, 91 min3 Sep 2025 11:18 GMT, 4.1 h3 Sep 2025 15:25 GMT, 10 min3 Sep 2025 15:39 GMT, 2 min3 Sep 2025 18:06 GMT, 12 min4 Sep 2025 07:12 GMT, 50 min4 Sep 2025 09:37 GMT, 65 min4 Sep 2025 10:44 GMT, 2 min4 Sep 2025 10:55 GMT, 7 min4 Sep 2025 11:22 GMT, 4 min13 Sep 2025 04:58 GMT, 44 min13 Sep 2025 07:54 GMT, 3.2 h13 Sep 2025 11:11 GMT, 14 min13 Sep 2025 11:34 GMT, 6 min13 Sep 2025 12:03 GMT, 2 min13 Sep 2025 12:23 GMT, 2 min14 Sep 2025 19:11 GMT, 9 min14 Sep 2025 19:30 GMT, 7 min14 Sep 2025 19:52 GMT, 6 min3 Oct 2025 23:58 GMT, 5.3 h22 Oct 2025 20:18 GMT, 23.5 h29 Oct 2025 15:21 GMT, 6.7 h1 Nov 2025 05:40 GMT, 5 h1 Nov 2025 17:52 GMT, 2.5 h2 Nov 2025 06:21 GMT, 12.7 h2 Nov 2025 19:17 GMT, 2.6 h10 Nov 2025 12:35 GMT, 14.4 h11 Nov 2025 09:05 GMT, 102 min23 Nov 2025 08:43 GMT, 9.2 h1 Dec 2025 19:38 GMT, 56.2 h4 Dec 2025 08:11 GMT, 18.7 h5 Dec 2025 08:17 GMT, 41.7 h7 Dec 2025 03:18 GMT, 84 h18 Dec 2025 04:41 GMT, 46.8 h20 Dec 2025 10:38 GMT, 102 min20 Dec 2025 13:36 GMT, 3 min20 Dec 2025 20:14 GMT, 5 min

Hours spilling by month, 2025

0100200300Jan 2025: 90 hours spillingJanFeb 2025: 41 hours spillingFebMar 2025: 0.0 hours spillingMarApr 2025: 0.0 hours spillingAprMay 2025: 0.0 hours spillingMayJun 2025: 0.0 hours spillingJunJul 2025: 0.8 hours spillingJulAug 2025: 2.1 hours spillingAugSep 2025: 17 hours spillingSepOct 2025: 36 hours spillingOctNov 2025: 48 hours spillingNovDec 2025: 249 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
7 Dec 2025, 03:18West Hoathly S.T.W.3.5 days
1 Dec 2025, 19:38West Hoathly S.T.W.2.3 days
18 Dec 2025, 04:41West Hoathly S.T.W.2.0 days
5 Jan 2025, 01:39West Hoathly S.T.W.1.9 days
5 Dec 2025, 08:17West Hoathly S.T.W.1.7 days

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate8,293 m³range 3,303 – 20,820 m³
In litres8.3 millionrange 3.3 million – 20.8 million L
Olympic swimming pools3.3at 2,500 m³ each
Organic load, as people's raw sewage12,440person-days of untreated BOD

Assumed spill rate while spilling: 1.9 – 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 132 kg746 kg4,164 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 347 kg3,525 kg15,011 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 6.3 kg52 kg194 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3–9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 4.0 kg22 kg112 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 330.3 billion organisms8.3 trillion organisms208.2 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

West Hoathly S.T.W.

Storm tank at sewage works · discharges to The Coombe Brook

Spills 2025
44 (484 hours) · down 19% on 2024
Spills 2024
54 (503 hours)
Long-term average
29.4 spills a year (monitored since 2017)
Monitor uptime
100% of the year
High-spill reason (company)
Not asset maintenance - Hydraulic capacity
Investigation
UWWTR investigation ongoing
Improvement
No improvement action in reporting period
WFD catchment
Medway at Weir Wood (GB106040018070)
Outlet location
TQ3748033510 (OS grid reference) · View on Apple Maps
EA ID / permit
SWS00923 · W00020 · company name: WEST HOATHLY SSO - 115792

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024–25 [EA]. Infiltration of groundwater into sewers is taken as 0–40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies – environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 – per capita consumption
  3. HBF: Foul sewer design – historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 – CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Southern Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.