Storm overflow register · Thames Water

Compton sewage works: storm overflow spills 2025

Compton sewage treatment works, run by Thames Water, has 1 monitored storm overflow discharging to River Pang. In 2025 it recorded 62 spills totalling 1,283 hours, against 52 spills and 1,018 hours in 2024. By hours spilling, it ranks 15 of 233 Thames Water works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecCompton Sewage…27 Jan 2025 23:45 GMT, 4.8 h28 Jan 2025 15:00 GMT, 13.3 h29 Jan 2025 05:45 GMT, 30 min29 Jan 2025 10:15 GMT, 2.5 h29 Jan 2025 17:15 GMT, 470.3 h25 Feb 2025 21:30 GMT, 142 h3 Mar 2025 20:00 GMT, 7.5 h4 Mar 2025 06:00 GMT, 3 h4 Mar 2025 09:30 GMT, 3.5 h4 Mar 2025 16:00 GMT, 30 min4 Mar 2025 23:15 GMT, 5.8 h5 Mar 2025 16:30 GMT, 377 h24 Mar 2025 01:15 GMT, 49.3 h26 Mar 2025 08:45 GMT, 4.3 h28 Mar 2025 04:45 GMT, 5 h28 Mar 2025 20:30 GMT, 45 min28 Mar 2025 22:15 GMT, 60 min28 Mar 2025 23:45 GMT, 11.5 h29 Mar 2025 11:45 GMT, 30 min29 Mar 2025 20:00 GMT, 75 min29 Mar 2025 22:00 GMT, 153.5 h9 Apr 2025 03:45 GMT, 105 min10 Apr 2025 02:00 GMT, 4 h11 Apr 2025 19:15 GMT, 5.3 h12 Apr 2025 01:15 GMT, 45 min12 Apr 2025 03:15 GMT, 9.8 h12 Apr 2025 19:45 GMT, 75 min13 Apr 2025 01:00 GMT, 3 h

Hours spilling by month, 2025

0200400600Jan 2025: 76 hours spillingJanFeb 2025: 490 hours spillingFebMar 2025: 588 hours spillingMarApr 2025: 129 hours spillingAprMay 2025: 0.0 hours spillingMayJun 2025: 0.0 hours spillingJunJul 2025: 0.0 hours spillingJulAug 2025: 0.0 hours spillingAugSep 2025: 0.0 hours spillingSepOct 2025: 0.0 hours spillingOctNov 2025: 0.0 hours spillingNovDec 2025: 0.0 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
29 Jan 2025, 17:15Compton Sewage Treatment Works19.6 days
5 Mar 2025, 16:30Compton Sewage Treatment Works15.7 days
29 Mar 2025, 22:00Compton Sewage Treatment Works6.4 days
25 Feb 2025, 21:30Compton Sewage Treatment Works5.9 days
24 Mar 2025, 01:15Compton Sewage Treatment Works2.1 days

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate21,987 m³range 8,758 – 55,199 m³
In litres22.0 millionrange 8.8 million – 55.2 million L
Olympic swimming pools8.8at 2,500 m³ each
Organic load, as people's raw sewage32,980person-days of untreated BOD

Assumed spill rate while spilling: 1.9 – 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 350 kg1,979 kg11,040 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 920 kg9,344 kg39,798 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 17 kg139 kg513 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3–9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 11 kg57 kg298 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 875.8 billion organisms22.0 trillion organisms552.0 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Compton Sewage Treatment Works

Storm tank at sewage works · discharges to River Pang

Spills 2025
62 (1,283 hours) · up 19% on 2024
Spills 2024
52 (1,018 hours)
Long-term average
29.8 spills a year (monitored since 2018)
Monitor uptime
100% of the year
High-spill reason (company)
Performance - GW inundation
Investigation
Env Act (SODRP) investigation ongoing
Improvement
No improvement action in reporting period
WFD catchment
Pang (GB106039023300)
Outlet location
SU5260079000 (OS grid reference) · View on Apple Maps
EA ID / permit
TWL00112 · CATM.3132 · company name: Compton STW

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024–25 [EA]. Infiltration of groundwater into sewers is taken as 0–40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies – environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 – per capita consumption
  3. HBF: Foul sewer design – historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 – CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Thames Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.