Storm overflow register · Thames Water

Mortimer sewage works: storm overflow spills 2025

Mortimer sewage treatment works, run by Thames Water, has 1 monitored storm overflow discharging to Foudry Brook. In 2025 it recorded 40 spills totalling 689 hours, against 63 spills and 674 hours in 2024. By hours spilling, it ranks 43 of 233 Thames Water works, where 1 spilled longest.

Works size: 4,582 population equivalent (STRATFIELD MORTIMER STW, UWWTD 2018). Used for the spill volume estimate.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecMortimer (Stratfield…5 Jan 2025 06:45 GMT, 91.3 h9 Jan 2025 08:15 GMT, 17.5 h10 Jan 2025 05:30 GMT, 30 min10 Jan 2025 07:00 GMT, 17.5 h11 Jan 2025 09:15 GMT, 5.5 h11 Jan 2025 19:00 GMT, 3 h12 Jan 2025 03:15 GMT, 60 min12 Jan 2025 09:30 GMT, 4.5 h12 Jan 2025 17:45 GMT, 3.3 h13 Jan 2025 06:45 GMT, 30 min13 Jan 2025 07:45 GMT, 3.5 h24 Jan 2025 09:45 GMT, 17 h25 Jan 2025 03:15 GMT, 30 min25 Jan 2025 08:30 GMT, 13 h25 Jan 2025 22:30 GMT, 90 min26 Jan 2025 01:15 GMT, 60 min26 Jan 2025 03:00 GMT, 60 min26 Jan 2025 12:15 GMT, 181 h3 Feb 2025 02:15 GMT, 90 min3 Feb 2025 05:00 GMT, 6.5 h3 Feb 2025 12:15 GMT, 2.3 h3 Feb 2025 19:15 GMT, 8.5 h4 Feb 2025 07:45 GMT, 2.3 h4 Feb 2025 10:45 GMT, 30 min10 Feb 2025 10:30 GMT, 15.3 h11 Feb 2025 06:45 GMT, 9.8 h11 Feb 2025 17:30 GMT, 7 h12 Feb 2025 07:45 GMT, 3.8 h12 Feb 2025 20:30 GMT, 90 min13 Feb 2025 08:15 GMT, 105 min24 Feb 2025 04:30 GMT, 119.8 h1 Mar 2025 07:45 GMT, 6 h1 Mar 2025 18:45 GMT, 3.8 h1 Mar 2025 23:00 GMT, 2.5 h2 Mar 2025 08:00 GMT, 5.8 h2 Mar 2025 18:30 GMT, 60 min2 Mar 2025 20:00 GMT, 3.3 h3 Mar 2025 05:45 GMT, 45 min3 Mar 2025 08:15 GMT, 3 h9 Dec 2025 11:15 GMT, 25.5 h10 Dec 2025 13:15 GMT, 30 min10 Dec 2025 20:15 GMT, 3.3 h11 Dec 2025 00:45 GMT, 4.8 h11 Dec 2025 07:15 GMT, 4.3 h18 Dec 2025 14:30 GMT, 74.3 h21 Dec 2025 17:15 GMT, 7.5 h

Estimated spill volume by month, 2025

Hours spilling each month × the estimated spill rate for a works of this size. The bars are central estimates and the whiskers show the low–high range. Method.

020k40k60k80kJan 2025: 314 h spilling ≈ 24,636 m³ (range 9,813–61,851 m³)JanFeb 2025: 225 h spilling ≈ 17,680 m³ (range 7,042–44,387 m³)FebMar 2025: 30 h spilling ≈ 2,371 m³ (range 944–5,952 m³)MarApr 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)AprMay 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)MayJun 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)JunJul 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)JulAug 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)AugSep 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)SepOct 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)OctNov 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)NovDec 2025: 120 h spilling ≈ 9,421 m³ (range 3,753–23,652 m³)Dec
Cubic metres (m³), estimate. Hours are measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDurationEstimated volume
26 Jan 2025, 12:15Mortimer (Stratfield Mortimer) WwTW7.5 days5,660 – 35,676 m³
24 Feb 2025, 04:30Mortimer (Stratfield Mortimer) WwTW5.0 days3,745 – 23,603 m³
5 Jan 2025, 06:45Mortimer (Stratfield Mortimer) WwTW3.8 days2,854 – 17,986 m³
18 Dec 2025, 14:30Mortimer (Stratfield Mortimer) WwTW3.1 days2,322 – 14,635 m³
9 Dec 2025, 11:15Mortimer (Stratfield Mortimer) WwTW1.1 days797 – 5,026 m³

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

Volume, central estimate54,109 m³range 21,553 – 135,843 m³
In litres54.1 millionrange 21.6 million – 135.8 million L
Olympic swimming pools22at 2,500 m³ each
Organic load, as people's raw sewage81,164person-days of untreated BOD

Assumed spill rate while spilling: 8.7 – 54.8 L/s (central 21.8 L/s), from a dry-weather flow of 8.7 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 862 kg4,870 kg27,169 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 2,263 kg22,996 kg97,943 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 41 kg341 kg1,263 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3–9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 26 kg141 kg734 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 2.2 trillion organisms54.1 trillion organisms1.4 × 10¹⁵ organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Mortimer (Stratfield Mortimer) WwTW

Storm tank at sewage works · discharges to Foudry Brook

Spills 2025
40 (689 hours) · down 37% on 2024
Spills 2024
63 (674 hours)
Long-term average
85.5 spills a year (monitored since 2018)
Monitor uptime
100% of the year
High-spill reason (company)
Performance - GW inundation
Investigation
No investigation activity in reporting period
Improvement
No improvement action in reporting period
WFD catchment
Foudry Brook (West End Brook to M4) (GB106039017380)
Outlet location
SU6746064500 (OS grid reference) · View on Apple Maps
EA ID / permit
TWL00306 · CNTW.0404 · company name: Mortimer STW

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024–25 [EA]. Infiltration of groundwater into sewers is taken as 0–40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies – environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 – per capita consumption
  3. HBF: Foul sewer design – historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 – CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Thames Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.