Storm overflow register · United Utilities

Arlecdon sewage works: storm overflow spills 2025

Arlecdon sewage treatment works, run by United Utilities, has 1 monitored storm overflow discharging to Dub Beck. In 2025 it recorded 68 spills totalling 188 hours, against 24 spills and 98 hours in 2024. By hours spilling, it ranks 195 of 289 United Utilities works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecArlecdon STW13 Jan 2025 16:20 GMT, 9 min24 Jan 2025 02:31 GMT, 3 min24 Jan 2025 03:04 GMT, 11 min4 Feb 2025 08:18 GMT, 4 min4 Feb 2025 11:15 GMT, 4 min20 Feb 2025 08:56 GMT, 12 min20 Feb 2025 09:23 GMT, 3 min21 Feb 2025 09:44 GMT, 5.2 h23 Feb 2025 11:27 GMT, 5.1 h24 Mar 2025 00:09 GMT, 21 min29 Mar 2025 16:32 GMT, 32 min27 May 2025 13:38 GMT, 15 min29 May 2025 04:54 GMT, 4 min29 May 2025 05:07 GMT, 52 min3 Jun 2025 02:09 GMT, 77 min3 Jun 2025 04:16 GMT, 11 min4 Jun 2025 14:36 GMT, 17 min4 Jun 2025 15:01 GMT, 11 min4 Jun 2025 17:21 GMT, 38 min9 Jun 2025 19:48 GMT, 67 min14 Jun 2025 08:31 GMT, 47 min21 Jun 2025 20:25 GMT, 8 min24 Jun 2025 07:55 GMT, 4 min26 Jun 2025 05:02 GMT, 71 min26 Jun 2025 10:08 GMT, 6 min1 Jul 2025 16:48 GMT, 2 min4 Jul 2025 14:46 GMT, 3.5 h14 Jul 2025 00:12 GMT, 12 min15 Jul 2025 06:01 GMT, 20 min15 Jul 2025 07:53 GMT, 34 min15 Jul 2025 08:38 GMT, 63 min15 Jul 2025 10:55 GMT, 50 min15 Jul 2025 11:53 GMT, 95 min15 Jul 2025 17:02 GMT, 25 min3 Aug 2025 05:34 GMT, 11 min4 Aug 2025 06:29 GMT, 78 min5 Aug 2025 09:08 GMT, 4 min5 Aug 2025 10:25 GMT, 21 min28 Aug 2025 10:25 GMT, 9 min28 Aug 2025 10:44 GMT, 6 min28 Aug 2025 11:10 GMT, 6 min28 Aug 2025 12:59 GMT, 7 min29 Aug 2025 17:12 GMT, 5 min1 Sep 2025 08:19 GMT, 1 min8 Sep 2025 17:18 GMT, 10 min12 Sep 2025 23:22 GMT, 8 min13 Sep 2025 00:44 GMT, 8 min13 Sep 2025 01:05 GMT, 25 min13 Sep 2025 01:42 GMT, 57 min13 Sep 2025 13:59 GMT, 17 min13 Sep 2025 19:59 GMT, 9 min15 Sep 2025 03:08 GMT, 18 min15 Sep 2025 08:33 GMT, 6 min15 Sep 2025 08:57 GMT, 65 min15 Sep 2025 10:16 GMT, 26 min17 Sep 2025 02:39 GMT, 19 min19 Sep 2025 00:47 GMT, 7 min19 Sep 2025 01:18 GMT, 102 min19 Sep 2025 05:52 GMT, 6.9 h19 Sep 2025 12:49 GMT, 3 min19 Sep 2025 17:03 GMT, 7 min19 Sep 2025 18:39 GMT, 7.8 h20 Sep 2025 05:41 GMT, 14 min20 Sep 2025 05:57 GMT, 78 min20 Sep 2025 07:22 GMT, 3 min20 Sep 2025 14:52 GMT, 2.4 h1 Oct 2025 06:31 GMT, 48 min2 Oct 2025 21:24 GMT, 2.6 h3 Oct 2025 11:41 GMT, 4.6 h3 Oct 2025 16:20 GMT, 5 min3 Oct 2025 16:54 GMT, 105 min4 Oct 2025 08:40 GMT, 15 min4 Oct 2025 09:06 GMT, 9 min1 Nov 2025 00:36 GMT, 12 min1 Nov 2025 03:58 GMT, 63 min2 Nov 2025 03:11 GMT, 8 min3 Nov 2025 00:37 GMT, 6.5 h3 Nov 2025 07:09 GMT, 11 min3 Nov 2025 08:04 GMT, 27 min4 Nov 2025 01:24 GMT, 2.4 h4 Nov 2025 03:51 GMT, 5 min4 Nov 2025 04:05 GMT, 34 min4 Nov 2025 05:48 GMT, 28 min4 Nov 2025 06:59 GMT, 16.3 h5 Nov 2025 00:58 GMT, 71 min5 Nov 2025 07:00 GMT, 71 min5 Nov 2025 10:27 GMT, 6.8 h5 Nov 2025 20:12 GMT, 89 min10 Nov 2025 02:29 GMT, 18 min11 Nov 2025 18:54 GMT, 8 min12 Nov 2025 22:06 GMT, 6.4 h18 Nov 2025 16:27 GMT, 5 min22 Nov 2025 00:51 GMT, 77 min22 Nov 2025 03:28 GMT, 86 min23 Nov 2025 04:50 GMT, 3.1 h23 Nov 2025 10:34 GMT, 19 min27 Nov 2025 05:35 GMT, 23 min27 Nov 2025 07:40 GMT, 26 min27 Nov 2025 08:29 GMT, 13 min29 Nov 2025 09:55 GMT, 26 min1 Dec 2025 03:28 GMT, 3 h1 Dec 2025 06:34 GMT, 119 min1 Dec 2025 16:42 GMT, 14 min1 Dec 2025 17:00 GMT, 4.7 h1 Dec 2025 21:54 GMT, 2.1 h5 Dec 2025 16:15 GMT, 2.2 h5 Dec 2025 21:27 GMT, 88 min5 Dec 2025 23:48 GMT, 43 min6 Dec 2025 00:40 GMT, 95 min6 Dec 2025 10:31 GMT, 15 min6 Dec 2025 18:10 GMT, 28 min7 Dec 2025 00:42 GMT, 33 min7 Dec 2025 15:43 GMT, 2.5 h9 Dec 2025 04:49 GMT, 6 min9 Dec 2025 05:38 GMT, 96 min9 Dec 2025 09:29 GMT, 3 h9 Dec 2025 12:37 GMT, 9 min9 Dec 2025 12:50 GMT, 23 min14 Dec 2025 01:43 GMT, 2.5 h14 Dec 2025 05:42 GMT, 89 min14 Dec 2025 09:49 GMT, 100 min14 Dec 2025 11:39 GMT, 4 min14 Dec 2025 12:19 GMT, 87 min14 Dec 2025 14:05 GMT, 14.6 h15 Dec 2025 04:47 GMT, 7 min15 Dec 2025 05:05 GMT, 5 min15 Dec 2025 05:19 GMT, 6 min15 Dec 2025 05:31 GMT, 58 min15 Dec 2025 06:31 GMT, 25 min15 Dec 2025 07:01 GMT, 10 min15 Dec 2025 07:17 GMT, 8 min15 Dec 2025 09:05 GMT, 3 min15 Dec 2025 09:19 GMT, 4 min15 Dec 2025 09:33 GMT, 7 min15 Dec 2025 09:50 GMT, 2 min15 Dec 2025 10:03 GMT, 5 min15 Dec 2025 10:16 GMT, 11 min15 Dec 2025 10:29 GMT, 12 min15 Dec 2025 10:44 GMT, 28 min15 Dec 2025 11:17 GMT, 10 min15 Dec 2025 11:31 GMT, 11 min15 Dec 2025 11:47 GMT, 6 min15 Dec 2025 22:43 GMT, 2 min15 Dec 2025 22:49 GMT, 1 min16 Dec 2025 00:49 GMT, 7 min16 Dec 2025 01:05 GMT, 6 min16 Dec 2025 02:22 GMT, 4 min16 Dec 2025 05:50 GMT, 15 min17 Dec 2025 11:14 GMT, 57 min17 Dec 2025 12:39 GMT, 110 min17 Dec 2025 14:41 GMT, 9.5 h18 Dec 2025 01:07 GMT, 57 min18 Dec 2025 19:08 GMT, 10 min18 Dec 2025 19:23 GMT, 21 min18 Dec 2025 19:52 GMT, 7 min24 Dec 2025 11:55 GMT, 38 min25 Dec 2025 20:46 GMT, 26 min27 Dec 2025 00:13 GMT, 25 min27 Dec 2025 02:34 GMT, 15 min

Hours spilling by month, 2025

020406080Jan 2025: 0.4 hours spillingJanFeb 2025: 11 hours spillingFebMar 2025: 0.9 hours spillingMarApr 2025: 0.0 hours spillingAprMay 2025: 1.2 hours spillingMayJun 2025: 6.0 hours spillingJunJul 2025: 8.5 hours spillingJulAug 2025: 2.5 hours spillingAugSep 2025: 25 hours spillingSepOct 2025: 10 hours spillingOctNov 2025: 53 hours spillingNovDec 2025: 69 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
4 Nov 2025, 06:59Arlecdon STW16.3 h
14 Dec 2025, 14:05Arlecdon STW14.6 h
17 Dec 2025, 14:41Arlecdon STW9.5 h
19 Sep 2025, 18:39Arlecdon STW7.8 h
19 Sep 2025, 05:52Arlecdon STW6.9 h

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate3,214 m³range 1,280 – 8,070 m³
In litres3.2 millionrange 1.3 million – 8.1 million L
Olympic swimming pools1.3at 2,500 m³ each
Organic load, as people's raw sewage4,822person-days of untreated BOD

Assumed spill rate while spilling: 1.9 – 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 51 kg289 kg1,614 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 134 kg1,366 kg5,818 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 2.4 kg20 kg75 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3–9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 1.5 kg8.4 kg44 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 128.0 billion organisms3.2 trillion organisms80.7 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Arlecdon STW

Inlet overflow at sewage works · discharges to Dub Beck

Spills 2025
68 (188 hours) · up 183% on 2024
Spills 2024
24 (98 hours)
Long-term average
35.2 spills a year (monitored since 2021)
Monitor uptime
100% of the year
High-spill reason (company)
Data collection - Confirmed exceptional weather
Investigation
No investigation activity in reporting period
Improvement
Env Act (SODRP) improvement ongoing
WFD catchment
Dub Beck (GB112074070020)
Outlet location
NY0472019130 (OS grid reference) · View on Apple Maps
EA ID / permit
UUP00132 · 017470024 · company name: ARLECDON WwTW

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024–25 [EA]. Infiltration of groundwater into sewers is taken as 0–40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies – environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 – per capita consumption
  3. HBF: Foul sewer design – historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 – CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All United Utilities works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.