Storm overflow register · United Utilities

Burton In Lonsdale sewage works: storm overflow spills 2025

Burton In Lonsdale sewage treatment works, run by United Utilities, has 1 monitored storm overflow discharging to River Greta. In 2025 it recorded 78 spills totalling 165 hours, against 95 spills and 263 hours in 2024. By hours spilling, it ranks 201 of 289 United Utilities works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecBurton-in-Lonsdale…9 spills, 13.6 h, 1 Jan to 1 Jan8 spills, 1.4 h, 5 Jan to 5 Jan4 spills, 1.2 h, 13 Jan to 14 Jan21 Jan 2025 01:41 GMT, 18 min6 spills, 21 h, 22 Jan to 24 Jan7 spills, 2.9 h, 25 Jan to 27 Jan31 Jan 2025 10:35 GMT, 108 min4 Feb 2025 13:20 GMT, 35 min20 Feb 2025 13:17 GMT, 14 min2 spills, 0.7 h, 26 Feb to 26 Feb22 Mar 2025 23:58 GMT, 10 min5 spills, 2.3 h, 26 May to 26 May3 spills, 3.5 h, 29 May to 29 May3 Jun 2025 05:00 GMT, 34 min3 spills, 0.9 h, 4 Jun to 5 Jun10 spills, 6.5 h, 6 Jun to 7 Jun8 Jun 2025 13:47 GMT, 15 min2 spills, 4.5 h, 9 Jun to 10 Jun3 spills, 1.7 h, 13 Jun to 14 Jun3 spills, 1.8 h, 28 Jun to 28 Jun2 spills, 3.3 h, 4 Jul to 4 Jul6 Jul 2025 20:29 GMT, 33 min5 spills, 1.2 h, 15 Jul to 15 Jul19 Jul 2025 07:58 GMT, 16 min6 spills, 4.5 h, 20 Jul to 20 Jul29 Jul 2025 19:46 GMT, 25 min2 spills, 1.1 h, 4 Aug to 4 Aug6 spills, 2.1 h, 1 Sep to 2 Sep2 spills, 0.4 h, 3 Sep to 3 Sep3 spills, 1 h, 7 Sep to 8 Sep14 spills, 2.7 h, 11 Sep to 11 Sep3 spills, 1.2 h, 12 Sep to 12 Sep13 Sep 2025 20:41 GMT, 28 min37 spills, 11 h, 15 Sep to 17 Sep28 spills, 23.4 h, 20 Sep to 21 Sep15 spills, 7.1 h, 3 Oct to 5 Oct7 Oct 2025 08:25 GMT, 13 min21 Oct 2025 14:31 GMT, 18 min26 Oct 2025 15:13 GMT, 17 min3 spills, 1.2 h, 29 Oct to 29 Oct23 spills, 8.7 h, 3 Nov to 5 Nov3 spills, 1.2 h, 9 Nov to 9 Nov10 Nov 2025 17:33 GMT, 14 min11 Nov 2025 19:32 GMT, 63 min2 spills, 0.6 h, 12 Nov to 12 Nov2 spills, 0.7 h, 18 Nov to 18 Nov2 spills, 0.4 h, 23 Nov to 23 Nov5 spills, 1.5 h, 26 Nov to 27 Nov2 spills, 0.8 h, 28 Nov to 28 Nov1 Dec 2025 23:00 GMT, 19 min24 spills, 10.7 h, 5 Dec to 7 Dec8 spills, 4.5 h, 9 Dec to 9 Dec10 Dec 2025 07:40 GMT, 41 min14 Dec 2025 11:56 GMT, 11 min6 spills, 1.4 h, 15 Dec to 15 Dec7 spills, 3.4 h, 17 Dec to 17 Dec18 Dec 2025 20:27 GMT, 6 min

Hours spilling by month, 2025

0204060Jan 2025: 42 hours spillingJanFeb 2025: 1.5 hours spillingFebMar 2025: 0.2 hours spillingMarApr 2025: 0.0 hours spillingAprMay 2025: 5.8 hours spillingMayJun 2025: 16 hours spillingJunJul 2025: 10 hours spillingJulAug 2025: 1.1 hours spillingAugSep 2025: 42 hours spillingSepOct 2025: 9.1 hours spillingOctNov 2025: 15 hours spillingNovDec 2025: 21 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
22 Jan 2025, 16:05Burton-in-Lonsdale WwTW17.2 h
1 Jan 2025, 00:00Burton-in-Lonsdale WwTW12.2 h
20 Sep 2025, 21:28Burton-in-Lonsdale WwTW11.1 h
9 Jun 2025, 19:59Burton-in-Lonsdale WwTW4.3 h
4 Jul 2025, 16:28Burton-in-Lonsdale WwTW2.8 h

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate2,824 m³range 1,125 - 7,089 m³
In litres2.8 millionrange 1.1 million - 7.1 million L
Olympic swimming pools1.1at 2,500 m³ each
Organic load, as people's raw sewage4,236person-days of untreated BOD

Assumed spill rate while spilling: 1.9 - 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 45 kg254 kg1,418 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 118 kg1,200 kg5,111 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 2.1 kg18 kg66 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3-9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 1.3 kg7.3 kg38 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 112.5 billion organisms2.8 trillion organisms70.9 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Burton-in-Lonsdale WwTW

Storm tank at sewage works · discharges to River Greta

Spills 2025
78 (165 hours) · down 18% on 2024
Spills 2024
95 (263 hours)
Long-term average
116.2 spills a year (monitored since 2021)
Monitor uptime
100% of the year
High-spill reason (company)
Not asset maintenance - Hydraulic capacity
Investigation
Operational investigation completed
Improvement
Env Act (SODRP) improvement ongoing, Operational improvement completed
WFD catchment
Greta (GB112072071610)
Outlet location
SD6495271922 (OS grid reference) · View on Apple Maps
EA ID / permit
UUP00377 · 017260021 · company name: BURTON-IN-LONSDALE WwTW

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024-25 [EA]. Infiltration of groundwater into sewers is taken as 0-40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies - environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 - per capita consumption
  3. HBF: Foul sewer design - historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 - CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All United Utilities works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.