Storm overflow register · United Utilities

Fazakerley sewage works: storm overflow spills 2025

Fazakerley sewage treatment works, run by United Utilities, has 1 monitored storm overflow discharging to River Alt. In 2025 it recorded 18 spills totalling 168 hours, against 67 spills and 447 hours in 2024. By hours spilling, it ranks 199 of 289 United Utilities works, where 1 spilled longest.

Works size: 166,653 population equivalent (NORTH LIVERPOOL( Fazakerley) STW, UWWTD 2018). Used for the spill volume estimate.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecFazakerley WwTW1 Jan 2025 00:05 GMT, 30.3 h5 Jan 2025 16:36 GMT, 77.6 h8 Jan 2025 22:20 GMT, 34 min25 Jun 2025 07:29 GMT, 1 min25 Jun 2025 07:35 GMT, 1 min25 Jun 2025 08:12 GMT, 2 min25 Jun 2025 08:45 GMT, 1 min26 Jun 2025 18:28 GMT, 4 min26 Jun 2025 18:39 GMT, 1 min26 Jun 2025 18:43 GMT, 3 min26 Jun 2025 19:01 GMT, 3 min26 Jun 2025 19:07 GMT, 2 min26 Jun 2025 19:09 GMT, 2 min26 Jun 2025 19:17 GMT, 5 min26 Jun 2025 19:25 GMT, 1 min26 Jun 2025 19:35 GMT, 1 min26 Jun 2025 19:48 GMT, 4 min26 Jun 2025 20:00 GMT, 2 min26 Jun 2025 20:05 GMT, 1 min26 Jun 2025 20:27 GMT, 1 min26 Jun 2025 20:43 GMT, 2 min26 Jun 2025 20:54 GMT, 2 min26 Jun 2025 21:01 GMT, 1 min26 Jun 2025 21:09 GMT, 2 min26 Jun 2025 21:13 GMT, 3 min26 Jun 2025 21:18 GMT, 2 min26 Jun 2025 21:25 GMT, 2 min26 Jun 2025 21:35 GMT, 2 min26 Jun 2025 21:40 GMT, 4 min26 Jun 2025 23:15 GMT, 1 min7 Jul 2025 07:40 GMT, 2 min7 Jul 2025 07:52 GMT, 68 min17 Sep 2025 06:15 GMT, 7.5 h20 Sep 2025 16:39 GMT, 13.5 h3 Oct 2025 14:45 GMT, 7.4 h4 Oct 2025 10:15 GMT, 3.9 h4 Oct 2025 15:54 GMT, 6 min4 Oct 2025 16:35 GMT, 4.4 h14 Nov 2025 18:32 GMT, 18.7 h19 Nov 2025 04:37 GMT, 2.2 h

Estimated spill volume by month, 2025

Hours spilling each month × the estimated spill rate for a works of this size. The bars are central estimates and the whiskers show the low–high range. Method.

0200k400k600k800kJan 2025: 108 h spilling ≈ 309,537 m³ (range 123,295–777,104 m³)JanFeb 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)FebMar 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)MarApr 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)AprMay 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)MayJun 2025: 0.9 h spilling ≈ 2,570 m³ (range 1,024–6,452 m³)JunJul 2025: 1.2 h spilling ≈ 3,427 m³ (range 1,365–8,603 m³)JulAug 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)AugSep 2025: 21 h spilling ≈ 59,680 m³ (range 23,772–149,829 m³)SepOct 2025: 16 h spilling ≈ 45,117 m³ (range 17,971–113,268 m³)OctNov 2025: 21 h spilling ≈ 59,680 m³ (range 23,772–149,829 m³)NovDec 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)Dec
Cubic metres (m³), estimate. Hours are measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDurationEstimated volume
5 Jan 2025, 16:36Fazakerley WwTW3.2 days88,282 – 556,423 m³
1 Jan 2025, 00:05Fazakerley WwTW1.3 days34,426 – 216,977 m³
14 Nov 2025, 18:32Fazakerley WwTW18.7 h21,232 – 133,819 m³
20 Sep 2025, 16:39Fazakerley WwTW13.5 h15,355 – 96,780 m³
17 Sep 2025, 06:15Fazakerley WwTW7.5 h8,474 – 53,408 m³

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

Volume, central estimate480,296 m³range 191,312 – 1.2 million m³
In litres480.3 millionrange 191.3 million – 1.2 billion L
Olympic swimming pools192at 2,500 m³ each
Organic load, as people's raw sewage720,444person-days of untreated BOD

Assumed spill rate while spilling: 315.9 – 1,991.3 L/s (central 793.2 L/s), from a dry-weather flow of 315.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 7,652 kg43,227 kg241,160 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 20,088 kg204,126 kg869,383 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 363 kg3,026 kg11,214 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3–9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 230 kg1,249 kg6,511 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 19.1 trillion organisms480.3 trillion organisms1.2 × 10¹⁶ organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Fazakerley WwTW

Storm tank at sewage works · discharges to River Alt

Spills 2025
18 (168 hours) · down 73% on 2024
Spills 2024
67 (447 hours)
Long-term average
61.2 spills a year (monitored since 2019)
Monitor uptime
100% of the year
Investigation
No investigation activity in reporting period
Improvement
No improvement action in reporting period
WFD catchment
Alt (GB112069060580)
Outlet location
SJ3958096340 (OS grid reference) · View on Apple Maps
EA ID / permit
UUP00724 · 016930112 · company name: FAZAKERLEY WwTW

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024–25 [EA]. Infiltration of groundwater into sewers is taken as 0–40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies – environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 – per capita consumption
  3. HBF: Foul sewer design – historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 – CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All United Utilities works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.