Storm overflow register · United Utilities

Kirkland sewage works: storm overflow spills 2025

Kirkland sewage treatment works, run by United Utilities, has 1 monitored storm overflow discharging to Hawes Gill. In 2025 it recorded 51 spills totalling 43 hours, against 55 spills and 51 hours in 2024. By hours spilling, it ranks 254 of 289 United Utilities works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecKirkland Wastewater…24 Jan 2025 01:42 GMT, 6 min4 Feb 2025 06:24 GMT, 6 min20 Feb 2025 09:00 GMT, 4 min21 Feb 2025 12:42 GMT, 8 min2 spills, 0.8 h, 23 Feb to 23 Feb27 Mar 2025 20:42 GMT, 6 min29 Mar 2025 16:12 GMT, 48 min24 May 2025 20:44 GMT, 8 min3 spills, 1.6 h, 3 Jun to 3 Jun2 spills, 0.3 h, 4 Jun to 4 Jun4 spills, 1.3 h, 9 Jun to 9 Jun3 spills, 0.6 h, 14 Jun to 14 Jun22 Jun 2025 21:42 GMT, 6 min24 Jun 2025 06:14 GMT, 24 min2 spills, 0.6 h, 26 Jun to 26 Jun5 spills, 3.5 h, 4 Jul to 4 Jul4 spills, 1.2 h, 15 Jul to 15 Jul20 Jul 2025 15:42 GMT, 6 min2 spills, 0.5 h, 3 Aug to 3 Aug3 spills, 1 h, 4 Aug to 4 Aug5 Aug 2025 09:10 GMT, 8 min4 spills, 0.8 h, 28 Aug to 29 Aug7 Sep 2025 17:36 GMT, 20 min3 spills, 0.7 h, 13 Sep to 13 Sep10 spills, 3.3 h, 19 Sep to 19 Sep9 spills, 3.7 h, 2 Oct to 4 Oct27 Oct 2025 22:54 GMT, 8 min4 spills, 1.2 h, 1 Nov to 1 Nov2 Nov 2025 03:12 GMT, 10 min6 spills, 2.3 h, 3 Nov to 3 Nov5 spills, 3.8 h, 4 Nov to 4 Nov10 Nov 2025 02:26 GMT, 8 min3 spills, 1.4 h, 13 Nov to 13 Nov2 spills, 1.1 h, 22 Nov to 22 Nov2 spills, 1.4 h, 23 Nov to 23 Nov27 Nov 2025 05:38 GMT, 18 min4 spills, 1.2 h, 1 Dec to 1 Dec5 Dec 2025 16:44 GMT, 44 min3 spills, 1.3 h, 7 Dec to 7 Dec12 Dec 2025 20:26 GMT, 4 min8 spills, 4.7 h, 14 Dec to 15 Dec2 spills, 0.4 h, 17 Dec to 17 Dec

Hours spilling by month, 2025

051015Jan 2025: 0.1 hours spillingJanFeb 2025: 1.1 hours spillingFebMar 2025: 0.9 hours spillingMarApr 2025: 0.0 hours spillingAprMay 2025: 0.1 hours spillingMayJun 2025: 5.0 hours spillingJunJul 2025: 4.7 hours spillingJulAug 2025: 2.4 hours spillingAugSep 2025: 4.3 hours spillingSepOct 2025: 3.9 hours spillingOctNov 2025: 12 hours spillingNovDec 2025: 8.4 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
14 Dec 2025, 22:12Kirkland Wastewater Treatment Works2.8 h
4 Nov 2025, 08:58Kirkland Wastewater Treatment Works1.9 h
23 Nov 2025, 04:52Kirkland Wastewater Treatment Works1.3 h
2 Oct 2025, 21:36Kirkland Wastewater Treatment Works1.2 h
3 Jun 2025, 02:02Kirkland Wastewater Treatment Works1.1 h

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate728 m³range 290 - 1,828 m³
In litres728,213range 290,063 - 1.8 million L
Olympic swimming pools0.3at 2,500 m³ each
Organic load, as people's raw sewage1,092person-days of untreated BOD

Assumed spill rate while spilling: 1.9 - 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 12 kg66 kg366 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 30 kg309 kg1,318 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 0.6 kg4.6 kg17 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3-9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 0.3 kg1.9 kg9.9 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 29.0 billion organisms728.2 billion organisms18.3 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Kirkland Wastewater Treatment Works

Inlet overflow at sewage works · discharges to Hawes Gill

Spills 2025
51 (43 hours) · down 7% on 2024
Spills 2024
55 (51 hours)
Long-term average
54.2 spills a year (monitored since 2021)
Monitor uptime
100% of the year
High-spill reason (company)
Data collection - Confirmed exceptional weather
Investigation
No investigation activity in reporting period
Improvement
No improvement action in reporting period
WFD catchment
Ehen (upper including Liza) (GB112074070010)
Outlet location
NY0733017430 (OS grid reference) · View on Apple Maps
EA ID / permit
UUP01086 · 017470029 · company name: KIRKLAND WwTW

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024-25 [EA]. Infiltration of groundwater into sewers is taken as 0-40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies - environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 - per capita consumption
  3. HBF: Foul sewer design - historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 - CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All United Utilities works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.