Kirkoswald sewage treatment works, run by United Utilities, has 1 monitored storm overflow discharging to Trib River Eden. In 2025 it recorded 40 spills totalling 95 hours, against 27 spills and 46 hours in 2024. By hours spilling, it ranks 229 of 289 United Utilities works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecKirkoswald WwTW3 spills, 3.1 h, 1 Jan to 1 Jan4 Jan 2025 03:59 GMT, 5 min12 spills, 1.4 h, 5 Jan to 6 Jan24 Jan 2025 03:10 GMT, 2 h26 Jan 2025 02:01 GMT, 37.3 h29 May 2025 05:31 GMT, 3.3 h3 Jun 2025 04:57 GMT, 41 min4 Jun 2025 15:25 GMT, 22 min7 Jun 2025 13:21 GMT, 31 min3 spills, 2.3 h, 9 Jun to 9 Jun3 spills, 3.2 h, 14 Jun to 14 Jun2 spills, 1.5 h, 21 Jun to 22 Jun3 spills, 1.5 h, 24 Jun to 24 Jun3 spills, 0.7 h, 15 Jul to 15 Jul11 Sep 2025 22:55 GMT, 11 min3 spills, 2.7 h, 14 Sep to 15 Sep13 spills, 11.8 h, 19 Sep to 20 Sep3 Oct 2025 13:58 GMT, 71 min1 Nov 2025 02:12 GMT, 8 min2 Nov 2025 02:27 GMT, 59 min5 spills, 4.9 h, 3 Nov to 4 Nov21 Nov 2025 11:28 GMT, 5 min2 spills, 1 h, 23 Nov to 23 Nov27 Nov 2025 07:39 GMT, 31 min28 Nov 2025 11:53 GMT, 14 min2 spills, 3.2 h, 1 Dec to 1 Dec7 spills, 6.3 h, 5 Dec to 7 Dec3 spills, 1.3 h, 9 Dec to 9 Dec10 Dec 2025 08:07 GMT, 12 min2 spills, 1.7 h, 14 Dec to 15 Dec18 Dec 2025 00:33 GMT, 20 min18 Dec 2025 20:24 GMT, 9 min

Hours spilling by month, 2025

0204060Jan 2025: 44 hours spillingJanFeb 2025: 0.0 hours spillingFebMar 2025: 0.0 hours spillingMarApr 2025: 0.0 hours spillingAprMay 2025: 3.3 hours spillingMayJun 2025: 10 hours spillingJunJul 2025: 0.7 hours spillingJulAug 2025: 0.0 hours spillingAugSep 2025: 15 hours spillingSepOct 2025: 1.2 hours spillingOctNov 2025: 7.8 hours spillingNovDec 2025: 13 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
26 Jan 2025, 02:01Kirkoswald WwTW1.6 days
20 Sep 2025, 16:34Kirkoswald WwTW3.9 h
7 Dec 2025, 16:37Kirkoswald WwTW3.3 h
29 May 2025, 05:31Kirkoswald WwTW3.3 h
1 Jan 2025, 02:46Kirkoswald WwTW3.0 h

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate1,623 m³range 646 - 4,074 m³
In litres1.6 millionrange 646,328 - 4.1 million L
Olympic swimming pools0.6at 2,500 m³ each
Organic load, as people's raw sewage2,434person-days of untreated BOD

Assumed spill rate while spilling: 1.9 - 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 26 kg146 kg815 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 68 kg690 kg2,937 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 1.2 kg10 kg38 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3-9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 0.8 kg4.2 kg22 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 64.6 billion organisms1.6 trillion organisms40.7 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Kirkoswald WwTW

Storm tank at sewage works · discharges to Trib River Eden

Spills 2025
40 (95 hours) · up 48% on 2024
Spills 2024
27 (46 hours)
Long-term average
20.2 spills a year (monitored since 2020)
Monitor uptime
100% of the year
High-spill reason (company)
Not asset maintenance - Hydraulic capacity
Investigation
Env Act (SODRP) investigation ongoing, Operational investigation completed
Improvement
Env Act (SODRP) improvement ongoing, Operational improvement completed
WFD catchment
Eden - Eamont to tidal (GB102076073940)
Outlet location
NY5471041200 (OS grid reference) · View on Apple Maps
EA ID / permit
UUP01087 · 017670065 · company name: KIRKOSWALD WwTW

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024-25 [EA]. Infiltration of groundwater into sewers is taken as 0-40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies - environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 - per capita consumption
  3. HBF: Foul sewer design - historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 - CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All United Utilities works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.