Storm overflow register · United Utilities

Oldham sewage works: storm overflow spills 2025

Oldham sewage treatment works, run by United Utilities, has 4 monitored storm overflows discharging to Wince Brook. In 2025 they recorded 38 spills totalling 369 hours, against 41 spills and 461 hours in 2024. By hours spilling, it ranks 135 of 289 United Utilities works, where 1 spilled longest.

Works size: 173,205 population equivalent (OLDHAM STW, UWWTD 2018). Used for the spill volume estimate.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecOldham WwTW1 Jan 2025 00:00 GMT, 32.2 h2 Jan 2025 09:33 GMT, 26 min2 Jan 2025 10:14 GMT, 48 min5 Jan 2025 20:11 GMT, 35.9 h7 Jan 2025 08:05 GMT, 69 min7 Jan 2025 09:16 GMT, 22 min11 Jan 2025 00:58 GMT, 4 min27 Jan 2025 03:29 GMT, 12 h27 Jan 2025 18:02 GMT, 35 min5 Jun 2025 11:06 GMT, 23 min5 Jun 2025 11:35 GMT, 6.8 h5 Jun 2025 18:23 GMT, 117 min5 Jun 2025 20:20 GMT, 25 min6 Jun 2025 09:05 GMT, 107 min6 Jun 2025 10:52 GMT, 32 min6 Jun 2025 12:00 GMT, 65 min6 Jun 2025 18:13 GMT, 6 min10 Jun 2025 05:02 GMT, 5 h15 Jul 2025 21:42 GMT, 2.9 h16 Jul 2025 00:34 GMT, 42 min11 Sep 2025 17:50 GMT, 4.6 h11 Sep 2025 22:27 GMT, 29 min12 Sep 2025 03:32 GMT, 22 min16 Sep 2025 07:49 GMT, 2.9 h16 Sep 2025 10:46 GMT, 52 min16 Sep 2025 13:11 GMT, 4.2 h16 Sep 2025 17:23 GMT, 2.4 h16 Sep 2025 21:06 GMT, 67 min17 Sep 2025 05:03 GMT, 15.2 h17 Sep 2025 20:15 GMT, 3.8 h18 Sep 2025 00:42 GMT, 46 min20 Sep 2025 15:12 GMT, 22.6 h22 Sep 2025 02:49 GMT, 18 min28 Sep 2025 01:44 GMT, 8.3 h28 Sep 2025 10:14 GMT, 2 min3 Oct 2025 16:56 GMT, 27.7 h4 Oct 2025 20:40 GMT, 2.7 h4 Oct 2025 23:56 GMT, 60 min5 Oct 2025 05:39 GMT, 2.1 h12 Nov 2025 01:36 GMT, 8.1 h12 Nov 2025 09:42 GMT, 82 min12 Nov 2025 16:12 GMT, 33 min12 Nov 2025 20:06 GMT, 10.2 h13 Nov 2025 07:22 GMT, 2.2 h14 Nov 2025 16:37 GMT, 28.7 h15 Nov 2025 21:32 GMT, 3.2 h16 Nov 2025 04:48 GMT, 35 min18 Nov 2025 16:19 GMT, 12.3 h19 Nov 2025 04:37 GMT, 4.4 h19 Nov 2025 09:03 GMT, 38 min23 Nov 2025 14:54 GMT, 14.9 h24 Nov 2025 05:48 GMT, 2.7 h24 Nov 2025 08:31 GMT, 113 min2 Dec 2025 01:29 GMT, 3.2 h9 Dec 2025 07:52 GMT, 19.2 h10 Dec 2025 04:43 GMT, 90 min10 Dec 2025 08:23 GMT, 45 min15 Dec 2025 05:53 GMT, 27.7 h16 Dec 2025 09:35 GMT, 112 min16 Dec 2025 11:54 GMT, 11 min16 Dec 2025 17:12 GMT, 23 min18 Dec 2025 16:08 GMT, 10.5 h19 Dec 2025 02:48 GMT, 5.4 hOldham WwTWOldham WwTWOldham WwTW

Estimated spill volume by month, 2025

Hours spilling each month × the estimated spill rate for a works of this size. The bars are central estimates and the whiskers show the low–high range. Method.

0200k400k600k800kJan 2025: 83 h spilling ≈ 247,512 m³ (range 98,589–621,389 m³)JanFeb 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)FebMar 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)MarApr 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)AprMay 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)MayJun 2025: 18 h spilling ≈ 53,420 m³ (range 21,278–134,113 m³)JunJul 2025: 3.6 h spilling ≈ 10,684 m³ (range 4,256–26,823 m³)JulAug 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)AugSep 2025: 68 h spilling ≈ 201,512 m³ (range 80,266–505,903 m³)SepOct 2025: 34 h spilling ≈ 99,420 m³ (range 39,601–249,599 m³)OctNov 2025: 92 h spilling ≈ 271,848 m³ (range 108,283–682,484 m³)NovDec 2025: 71 h spilling ≈ 209,821 m³ (range 83,576–526,765 m³)Dec
Cubic metres (m³), estimate. Hours are measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDurationEstimated volume
5 Jan 2025, 20:11Oldham WwTW1.5 days42,419 – 267,356 m³
1 Jan 2025, 00:00Oldham WwTW1.3 days38,025 – 239,664 m³
14 Nov 2025, 16:37Oldham WwTW1.2 days33,888 – 213,587 m³
3 Oct 2025, 16:56Oldham WwTW1.2 days32,765 – 206,509 m³
15 Dec 2025, 05:53Oldham WwTW1.2 days32,745 – 206,384 m³

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

Volume, central estimate1.1 million m³range 435,849 – 2.7 million m³
In litres1.1 billionrange 435.8 million – 2.7 billion L
Olympic swimming pools438at 2,500 m³ each
Organic load, as people's raw sewage1.6 millionperson-days of untreated BOD

Assumed spill rate while spilling: 328.4 – 2,069.6 L/s (central 824.4 L/s), from a dry-weather flow of 328.4 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 17,434 kg98,479 kg549,415 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 45,764 kg465,042 kg2.0 million kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 828 kg6,894 kg25,548 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3–9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 523 kg2,845 kg14,834 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 43.6 trillion organisms1.1 × 10¹⁵ organisms2.7 × 10¹⁶ organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Oldham WwTW

Storm tank at sewage works · discharges to Wince Brook

Spills 2025
38 (369 hours) · down 7% on 2024
Spills 2024
41 (461 hours)
Long-term average
19.8 spills a year (monitored since 2021)
Monitor uptime
100% of the year
High-spill reason (company)
Not asset maintenance - Hydraulic capacity
Investigation
No investigation activity in reporting period
Improvement
No improvement action in reporting period
WFD catchment
Wince Brook (GB112069061120)
Outlet location
SD8937004430 (OS grid reference) · View on Apple Maps
EA ID / permit
UUP01461 · 016950038 · company name: OLDHAM WwTW

Oldham WwTW

Inlet overflow at sewage works · discharges to Wince Brook

Spills 2025
0 (0.0 hours) · no change on 2024
Spills 2024
0 (0.0 hours)
Long-term average
0.0 spills a year (monitored since 2021)
Monitor uptime
100% of the year
Investigation
Env Act (SODRP) investigation ongoing
Improvement
No improvement action in reporting period
WFD catchment
Wince Brook (GB112069061120)
Outlet location
SD8937004430 (OS grid reference) · View on Apple Maps
EA ID / permit
UUP01459 · 016950038 · company name: OLDHAM WwTW

Oldham WwTW

Storm tank at sewage works · discharges to Wince Brook

Spills 2025
0 (0.0 hours) · no change on 2024
Spills 2024
0 (0.0 hours)
Long-term average
0.4 spills a year (monitored since 2021)
Monitor uptime
100% of the year
Investigation
Env Act (SODRP) investigation ongoing
Improvement
No improvement action in reporting period
WFD catchment
Wince Brook (GB112069061120)
Outlet location
SD8937004430 (OS grid reference) · View on Apple Maps
EA ID / permit
UUP01460 · 016950038 · company name: OLDHAM WwTW

Oldham WwTW

Storm tank at sewage works · discharges to Wince Brook

Spills 2025
0 (0.0 hours) · no change on 2024
Spills 2024
0 (0.0 hours)
Long-term average
18.4 spills a year (monitored since 2021)
Monitor uptime
100% of the year
Investigation
No investigation activity in reporting period
Improvement
No improvement action in reporting period
WFD catchment
Wince Brook (GB112069061120)
Outlet location
SD8937004430 (OS grid reference) · View on Apple Maps
EA ID / permit
UUP01458 · 016950038 · company name: OLDHAM WwTW

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024–25 [EA]. Infiltration of groundwater into sewers is taken as 0–40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies – environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 – per capita consumption
  3. HBF: Foul sewer design – historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 – CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All United Utilities works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.