Storm overflow register · United Utilities

Runcorn sewage works: storm overflow spills 2025

Runcorn sewage treatment works, run by United Utilities, has 1 monitored storm overflow discharging to Manchester Ship Canal. In 2025 it recorded 21 spills totalling 218 hours, against 63 spills and 720 hours in 2024. By hours spilling, it ranks 184 of 289 United Utilities works, where 1 spilled longest.

Works size: 93,293 population equivalent (RUNCORN STW, UWWTD 2018). Used for the spill volume estimate.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecRuncorn Wastewater…1 Jan 2025 00:00 GMT, 24.7 h5 Jan 2025 14:52 GMT, 79.5 h27 Jan 2025 03:10 GMT, 6.9 h17 Sep 2025 06:06 GMT, 7.9 h20 Sep 2025 16:40 GMT, 18 h3 Oct 2025 15:07 GMT, 4.2 h4 Oct 2025 12:14 GMT, 2.7 h11 Nov 2025 21:27 GMT, 4.7 h14 Nov 2025 11:44 GMT, 26 h18 Nov 2025 19:27 GMT, 14.4 h4 Dec 2025 14:19 GMT, 3.5 h9 Dec 2025 10:00 GMT, 9 h15 Dec 2025 07:51 GMT, 16.9 h

Estimated spill volume by month, 2025

Hours spilling each month × the estimated spill rate for a works of this size. The bars are central estimates and the whiskers show the low–high range. Method.

0200k400k600kJan 2025: 111 h spilling ≈ 177,596 m³ (range 70,740–445,861 m³)JanFeb 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)FebMar 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)MarApr 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)AprMay 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)MayJun 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)JunJul 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)JulAug 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)AugSep 2025: 26 h spilling ≈ 41,402 m³ (range 16,491–103,941 m³)SepOct 2025: 6.9 h spilling ≈ 11,030 m³ (range 4,393–27,691 m³)OctNov 2025: 45 h spilling ≈ 72,093 m³ (range 28,716–180,993 m³)NovDec 2025: 29 h spilling ≈ 46,997 m³ (range 18,720–117,987 m³)Dec
Cubic metres (m³), estimate. Hours are measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDurationEstimated volume
5 Jan 2025, 14:52Runcorn Wastewater Treatment Works3.3 days50,598 – 318,912 m³
14 Nov 2025, 11:44Runcorn Wastewater Treatment Works1.1 days16,544 – 104,275 m³
1 Jan 2025, 00:00Runcorn Wastewater Treatment Works1.0 days15,748 – 99,259 m³
20 Sep 2025, 16:40Runcorn Wastewater Treatment Works18.0 h11,461 – 72,237 m³
15 Dec 2025, 07:51Runcorn Wastewater Treatment Works16.9 h10,739 – 67,689 m³

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

Volume, central estimate348,957 m³range 138,997 – 876,071 m³
In litres349.0 millionrange 139.0 million – 876.1 million L
Olympic swimming pools140at 2,500 m³ each
Organic load, as people's raw sewage523,436person-days of untreated BOD

Assumed spill rate while spilling: 176.9 – 1,114.8 L/s (central 444.0 L/s), from a dry-weather flow of 176.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 5,560 kg31,406 kg175,214 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 14,595 kg148,307 kg631,648 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 264 kg2,198 kg8,147 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3–9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 167 kg907 kg4,731 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 13.9 trillion organisms349.0 trillion organisms8.8 × 10¹⁵ organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Runcorn Wastewater Treatment Works

Storm tank at sewage works · discharges to Manchester Ship Canal

Spills 2025
21 (218 hours) · down 67% on 2024
Spills 2024
63 (720 hours)
Long-term average
38.6 spills a year (monitored since 2019)
Monitor uptime
100% of the year
Investigation
Env Act (SODRP) investigation ongoing
Improvement
No improvement action in reporting period
WFD catchment
Manchester Ship Canal (GB71210004)
Outlet location
SJ5398083766 (OS grid reference) · View on Apple Maps
EA ID / permit
UUP01698 · 016820127 · company name: RUNCORN WwTW

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024–25 [EA]. Infiltration of groundwater into sewers is taken as 0–40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies – environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 – per capita consumption
  3. HBF: Foul sewer design – historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 – CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All United Utilities works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.