Storm overflow register · United Utilities

Temple Sowerby sewage works: storm overflow spills 2025

Temple Sowerby sewage treatment works, run by United Utilities, has 1 monitored storm overflow discharging to Birk Syke. In 2025 it recorded 123 spills totalling 380 hours, against 184 spills and 1,258 hours in 2024. By hours spilling, it ranks 129 of 289 United Utilities works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecTemple Sowerby WwTW3 spills, 7.5 h, 1 Jan to 1 Jan4 spills, 4.3 h, 5 Jan to 6 Jan3 spills, 8.8 h, 24 Jan to 24 Jan4 spills, 5.4 h, 26 Jan to 28 Jan2 spills, 6.3 h, 31 Jan to 31 Jan3 spills, 1.9 h, 4 Feb to 5 Feb10 spills, 9.6 h, 20 Feb to 21 Feb5 spills, 10.7 h, 23 Feb to 24 Feb3 spills, 1.2 h, 24 Feb to 25 Feb26 Feb 2025 17:49 GMT, 27 min3 spills, 0.1 h, 27 Feb to 28 Feb12 Mar 2025 14:15 GMT, 13 min14 Mar 2025 19:43 GMT, 7 min3 spills, 2.2 h, 22 Mar to 23 Mar28 Mar 2025 15:46 GMT, 54 min14 Apr 2025 21:18 GMT, 63 min16 Apr 2025 16:00 GMT, 113 min2 spills, 2.2 h, 18 Apr to 18 Apr2 spills, 2.5 h, 23 May to 24 May25 May 2025 04:27 GMT, 25 min27 May 2025 15:28 GMT, 42 min2 spills, 11 h, 29 May to 29 May2 spills, 4.5 h, 3 Jun to 3 Jun5 spills, 4.1 h, 4 Jun to 5 Jun6 Jun 2025 06:24 GMT, 72 min5 spills, 7.1 h, 7 Jun to 7 Jun3 spills, 2.8 h, 9 Jun to 10 Jun5 spills, 5.2 h, 13 Jun to 14 Jun2 spills, 0.9 h, 22 Jun to 23 Jun2 spills, 0.5 h, 26 Jun to 26 Jun3 spills, 2.9 h, 1 Jul to 2 Jul3 Jul 2025 19:34 GMT, 48 min4 Jul 2025 17:43 GMT, 50 min5 spills, 2.7 h, 6 Jul to 6 Jul6 spills, 4.9 h, 14 Jul to 15 Jul3 spills, 4.8 h, 19 Jul to 19 Jul20 Jul 2025 16:34 GMT, 86 min21 Jul 2025 17:43 GMT, 67 min1 Aug 2025 04:01 GMT, 27 min3 Aug 2025 07:14 GMT, 37 min2 spills, 2.5 h, 4 Aug to 4 Aug5 Aug 2025 14:17 GMT, 25 min11 Aug 2025 19:31 GMT, 22 min27 Aug 2025 13:23 GMT, 19 min3 spills, 2.1 h, 30 Aug to 31 Aug4 spills, 4.9 h, 2 Sep to 3 Sep4 Sep 2025 13:12 GMT, 76 min7 Sep 2025 13:47 GMT, 2.7 h3 spills, 4 h, 11 Sep to 11 Sep8 spills, 6.6 h, 12 Sep to 14 Sep15 spills, 17.2 h, 14 Sep to 17 Sep3 spills, 23.1 h, 19 Sep to 20 Sep27 Sep 2025 19:16 GMT, 71 min2 spills, 3.6 h, 1 Oct to 1 Oct4 spills, 10.2 h, 2 Oct to 4 Oct6 Oct 2025 10:44 GMT, 17 min2 spills, 0.3 h, 7 Oct to 8 Oct3 spills, 4.2 h, 19 Oct to 19 Oct3 spills, 1.3 h, 21 Oct to 21 Oct2 spills, 1.8 h, 24 Oct to 24 Oct2 spills, 1.4 h, 26 Oct to 26 Oct27 Oct 2025 23:40 GMT, 65 min29 Oct 2025 01:04 GMT, 12 min31 Oct 2025 00:17 GMT, 58 min7 spills, 6.6 h, 1 Nov to 2 Nov8 spills, 10 h, 3 Nov to 4 Nov2 spills, 3.4 h, 5 Nov to 5 Nov10 Nov 2025 02:38 GMT, 81 min3 spills, 4.7 h, 11 Nov to 11 Nov3 spills, 25 h, 12 Nov to 13 Nov2 spills, 0.6 h, 14 Nov to 15 Nov4 spills, 3.6 h, 18 Nov to 19 Nov7 spills, 7.6 h, 23 Nov to 23 Nov3 spills, 1.9 h, 26 Nov to 27 Nov3 spills, 3.6 h, 28 Nov to 28 Nov8 spills, 17.1 h, 1 Dec to 2 Dec3 spills, 6 h, 4 Dec to 4 Dec17 spills, 38.2 h, 5 Dec to 10 Dec2 spills, 3 h, 12 Dec to 12 Dec3 spills, 15.2 h, 14 Dec to 15 Dec16 Dec 2025 19:50 GMT, 23 min3 spills, 7.5 h, 17 Dec to 18 Dec6 spills, 5.7 h, 18 Dec to 19 Dec21 Dec 2025 10:24 GMT, 23 min

Hours spilling by month, 2025

0255075100Jan 2025: 32 hours spillingJanFeb 2025: 24 hours spillingFebMar 2025: 3.4 hours spillingMarApr 2025: 5.2 hours spillingAprMay 2025: 15 hours spillingMayJun 2025: 26 hours spillingJunJul 2025: 20 hours spillingJulAug 2025: 6.8 hours spillingAugSep 2025: 61 hours spillingSepOct 2025: 25 hours spillingOctNov 2025: 68 hours spillingNovDec 2025: 94 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
9 Dec 2025, 04:15Temple Sowerby WwTW11.4 h
20 Sep 2025, 12:25Temple Sowerby WwTW11.4 h
12 Nov 2025, 20:48Temple Sowerby WwTW10.2 h
13 Nov 2025, 07:02Temple Sowerby WwTW9.6 h
29 May 2025, 00:58Temple Sowerby WwTW8.1 h

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate6,508 m³range 2,592 - 16,338 m³
In litres6.5 millionrange 2.6 million - 16.3 million L
Olympic swimming pools2.6at 2,500 m³ each
Organic load, as people's raw sewage9,761person-days of untreated BOD

Assumed spill rate while spilling: 1.9 - 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 104 kg586 kg3,268 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 272 kg2,766 kg11,780 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 4.9 kg41 kg152 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3-9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 3.1 kg17 kg88 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 259.2 billion organisms6.5 trillion organisms163.4 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Temple Sowerby WwTW

Inlet overflow at sewage works · discharges to Birk Syke

Spills 2025
123 (380 hours) · down 33% on 2024
Spills 2024
184 (1,258 hours)
Long-term average
192.7 spills a year (monitored since 2020)
Monitor uptime
100% of the year
High-spill reason (company)
Performance - SW Infiltration
Investigation
No investigation activity in reporting period
Improvement
No improvement action in reporting period
WFD catchment
Crowdundle Beck - Lower (GB102076070950)
Outlet location
NY6106027880 (OS grid reference) · View on Apple Maps
EA ID / permit
UUP01906 · 017670042 · company name: TEMPLE SOWERBY WwTW

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024-25 [EA]. Infiltration of groundwater into sewers is taken as 0-40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies - environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 - per capita consumption
  3. HBF: Foul sewer design - historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 - CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All United Utilities works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.