Storm overflow register · United Utilities

Waddington sewage works: storm overflow spills 2025

Waddington sewage treatment works, run by United Utilities, has 1 monitored storm overflow discharging to Bashall Brook. In 2025 it recorded 145 spills totalling 1,935 hours, against 166 spills and 2,288 hours in 2024. By hours spilling, it ranks 10 of 289 United Utilities works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecWaddington WwTW5 spills, 200.2 h, 1 Jan to 10 Jan5 spills, 73.1 h, 13 Jan to 17 Jan10 spills, 169.6 h, 21 Jan to 29 Jan4 spills, 24.6 h, 31 Jan to 2 Feb3 spills, 8.1 h, 19 Feb to 20 Feb21 Feb 2025 18:55 GMT, 32 min5 spills, 13.1 h, 23 Feb to 24 Feb26 Feb 2025 07:30 GMT, 66 min7 Mar 2025 08:54 GMT, 20 min23 Mar 2025 03:41 GMT, 94 min29 Mar 2025 18:48 GMT, 56 min2 spills, 4.4 h, 24 May to 24 May6 spills, 14.2 h, 25 May to 27 May2 spills, 23.4 h, 29 May to 30 May4 spills, 8.4 h, 3 Jun to 4 Jun6 spills, 59.2 h, 4 Jun to 8 Jun9 Jun 2025 20:48 GMT, 29.6 h14 Jun 2025 00:15 GMT, 2.7 h4 spills, 4 h, 22 Jun to 23 Jun24 Jun 2025 08:39 GMT, 55 min28 Jun 2025 22:02 GMT, 2.4 h2 spills, 14.5 h, 4 Jul to 5 Jul2 spills, 1.9 h, 6 Jul to 6 Jul2 spills, 3.6 h, 15 Jul to 15 Jul19 Jul 2025 08:08 GMT, 41 min20 Jul 2025 12:29 GMT, 9.3 h4 spills, 6.6 h, 4 Aug to 5 Aug29 Aug 2025 10:32 GMT, 36 min4 spills, 3.1 h, 1 Sep to 1 Sep2 spills, 1.4 h, 7 Sep to 7 Sep12 spills, 158.5 h, 10 Sep to 18 Sep3 spills, 74.2 h, 19 Sep to 23 Sep2 spills, 3.8 h, 27 Sep to 28 Sep4 spills, 91 h, 2 Oct to 6 Oct7 Oct 2025 18:56 GMT, 63 min3 spills, 5.3 h, 19 Oct to 19 Oct4 spills, 13.5 h, 21 Oct to 21 Oct7 spills, 61.8 h, 26 Oct to 29 Oct9 spills, 115.8 h, 1 Nov to 7 Nov8 Nov 2025 09:00 GMT, 19 min18 spills, 146.2 h, 9 Nov to 16 Nov18 Nov 2025 10:11 GMT, 25.8 h14 spills, 31.3 h, 22 Nov to 24 Nov3 spills, 2.5 h, 26 Nov to 27 Nov11 spills, 99.5 h, 28 Nov to 3 Dec20 spills, 420.8 h, 4 Dec to 23 Dec

Hours spilling by month, 2025

0200400600Jan 2025: 463 hours spillingJanFeb 2025: 28 hours spillingFebMar 2025: 2.8 hours spillingMarApr 2025: 0.0 hours spillingAprMay 2025: 42 hours spillingMayJun 2025: 107 hours spillingJunJul 2025: 30 hours spillingJulAug 2025: 7.2 hours spillingAugSep 2025: 241 hours spillingSepOct 2025: 173 hours spillingOctNov 2025: 369 hours spillingNovDec 2025: 473 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
1 Jan 2025, 00:00Waddington WwTW7.4 days
16 Dec 2025, 08:27Waddington WwTW7.1 days
5 Dec 2025, 16:21Waddington WwTW6.7 days
15 Sep 2025, 01:29Waddington WwTW3.9 days
3 Nov 2025, 12:39Waddington WwTW3.5 days

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate33,159 m³range 13,208 - 83,246 m³
In litres33.2 millionrange 13.2 million - 83.2 million L
Olympic swimming pools13at 2,500 m³ each
Organic load, as people's raw sewage49,738person-days of untreated BOD

Assumed spill rate while spilling: 1.9 - 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 528 kg2,984 kg16,649 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 1,387 kg14,092 kg60,020 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 25 kg209 kg774 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3-9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 16 kg86 kg450 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 1.3 trillion organisms33.2 trillion organisms832.5 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Waddington WwTW

Storm tank at sewage works · discharges to Bashall Brook

Spills 2025
145 (1,935 hours) · down 13% on 2024
Spills 2024
166 (2,288 hours)
Long-term average
188.8 spills a year (monitored since 2017)
Monitor uptime
100% of the year
High-spill reason (company)
Not asset maintenance - Hydraulic capacity
Investigation
No investigation activity in reporting period
Improvement
Env Act (SODRP) improvement ongoing
Bathing water
River Ribble at Edisford Bridge
WFD catchment
Bashall Brook (GB112071065520)
Outlet location
SD7230043050 (OS grid reference) · View on Apple Maps
EA ID / permit
UUP02003 · 017160048 · company name: WADDINGTON WwTW

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024-25 [EA]. Infiltration of groundwater into sewers is taken as 0-40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies - environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 - per capita consumption
  3. HBF: Foul sewer design - historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 - CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All United Utilities works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.