Storm overflow register · Wessex Water

Hindon sewage works: storm overflow spills 2025

Hindon sewage treatment works, run by Wessex Water, has 1 monitored storm overflow discharging to Groundwater via Infilt System. In 2025 it recorded 74 spills totalling 97 hours, against 129 spills and 1,139 hours in 2024. By hours spilling, it ranks 184 of 242 Wessex Water works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecHindon Wastewater…11 spills, 0.7 h, 1 Jan to 1 Jan58 spills, 6.7 h, 4 Jan to 6 Jan9 Jan 2025 11:11 GMT, 1 min11 spills, 2.6 h, 23 Jan to 25 Jan12 spills, 9.3 h, 26 Jan to 28 Jan4 spills, 0.9 h, 31 Jan to 31 Jan491 spills, 27.4 h, 2 Feb to 4 Feb3 spills, 1.2 h, 10 Feb to 10 Feb2 spills, 0.2 h, 20 Feb to 20 Feb6 spills, 1 h, 21 Feb to 21 Feb3 spills, 4.8 h, 23 Feb to 24 Feb2 spills, 1.3 h, 25 Feb to 25 Feb4 spills, 2.5 h, 26 Feb to 26 Feb2 spills, 0 h, 21 Apr to 21 Apr23 Apr 2025 02:21 GMT, 55 min3 spills, 0.4 h, 21 May to 21 May2 spills, 0.1 h, 27 May to 27 May1 Jun 2025 18:36 GMT, 3 min3 Jun 2025 12:09 GMT, 29 min4 Jun 2025 10:23 GMT, 13 min4 spills, 1 h, 5 Jun to 5 Jun9 spills, 0.9 h, 7 Jun to 7 Jun12 Jun 2025 11:24 GMT, 85 min7 Jul 2025 03:20 GMT, 19 min31 Jul 2025 16:57 GMT, 1 min2 Aug 2025 09:13 GMT, 6 min3 Aug 2025 15:11 GMT, 1 min12 Aug 2025 01:16 GMT, 32 min3 spills, 0.8 h, 27 Aug to 27 Aug3 spills, 0.8 h, 29 Aug to 29 Aug11 spills, 2 h, 2 Sep to 3 Sep9 Sep 2025 23:23 GMT, 29 min11 Sep 2025 12:13 GMT, 10 min2 spills, 0.6 h, 13 Sep to 13 Sep2 spills, 0.5 h, 14 Sep to 14 Sep20 Sep 2025 15:58 GMT, 5 min24 Sep 2025 23:42 GMT, 4 min2 spills, 1 h, 3 Oct to 3 Oct3 spills, 0.1 h, 3 Oct to 3 Oct19 Oct 2025 11:33 GMT, 27 min2 spills, 0.4 h, 20 Oct to 20 Oct2 spills, 0.1 h, 22 Oct to 22 Oct3 spills, 0.7 h, 31 Oct to 31 Oct4 Nov 2025 17:48 GMT, 2 min2 spills, 0.4 h, 5 Nov to 5 Nov12 spills, 3.4 h, 10 Nov to 10 Nov8 spills, 0.6 h, 11 Nov to 11 Nov7 spills, 2.2 h, 13 Nov to 14 Nov4 spills, 1 h, 22 Nov to 23 Nov2 spills, 2 h, 29 Nov to 29 Nov7 spills, 2.2 h, 1 Dec to 1 Dec4 Dec 2025 07:20 GMT, 56 min3 spills, 2.6 h, 5 Dec to 5 Dec7 spills, 0.7 h, 7 Dec to 7 Dec3 spills, 0.2 h, 8 Dec to 9 Dec4 spills, 2.4 h, 15 Dec to 15 Dec2 spills, 5.2 h, 18 Dec to 18 Dec

Hours spilling by month, 2025

010203040Jan 2025: 20 hours spillingJanFeb 2025: 38 hours spillingFebMar 2025: 0.0 hours spillingMarApr 2025: 0.9 hours spillingAprMay 2025: 0.5 hours spillingMayJun 2025: 4.0 hours spillingJunJul 2025: 0.3 hours spillingJulAug 2025: 2.2 hours spillingAugSep 2025: 3.8 hours spillingSepOct 2025: 2.6 hours spillingOctNov 2025: 9.5 hours spillingNovDec 2025: 14 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
18 Dec 2025, 10:32Hindon Wastewater Treatment Works5.2 h
26 Jan 2025, 10:29Hindon Wastewater Treatment Works4.2 h
26 Jan 2025, 21:15Hindon Wastewater Treatment Works2.2 h
23 Feb 2025, 23:57Hindon Wastewater Treatment Works2.2 h
5 Dec 2025, 16:25Hindon Wastewater Treatment Works2.0 h

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate1,659 m³range 661 - 4,164 m³
In litres1.7 millionrange 660,660 - 4.2 million L
Olympic swimming pools0.7at 2,500 m³ each
Organic load, as people's raw sewage2,488person-days of untreated BOD

Assumed spill rate while spilling: 1.9 - 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 26 kg149 kg833 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 69 kg705 kg3,002 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 1.3 kg10 kg39 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3-9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 0.8 kg4.3 kg22 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 66.1 billion organisms1.7 trillion organisms41.6 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Hindon Wastewater Treatment Works

Inlet overflow at sewage works (with treatment) · discharges to Groundwater via Infilt System

Spills 2025
74 (97 hours) · down 43% on 2024
Spills 2024
129 (1,139 hours)
Long-term average
76.8 spills a year (monitored since 2020)
Monitor uptime
100% of the year
High-spill reason (company)
Not Applicable - Ongoing investigation
Investigation
Env Act (SODRP) investigation ongoing, UWWTR investigation ongoing
Improvement
No improvement action in reporting period
WFD catchment
Fonthill Stream (GB108043022500)
Outlet location
ST9165032750 (OS grid reference) · View on Apple Maps
EA ID / permit
WXW00545 · 402489 · company name: HINDON INLET

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024-25 [EA]. Infiltration of groundwater into sewers is taken as 0-40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies - environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 - per capita consumption
  3. HBF: Foul sewer design - historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 - CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Wessex Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.