Storm overflow register · Wessex Water

Sturminster Newton sewage works: storm overflow spills 2025

Sturminster Newton sewage treatment works, run by Wessex Water, has 2 monitored storm overflows discharging to River Stour. In 2025 they recorded 48 spills totalling 420 hours, against 74 spills and 615 hours in 2024. By hours spilling, it ranks 97 of 242 Wessex Water works, where 1 spilled longest.

Works size: 6,856 population equivalent (STURMINSTER NEWTON STW, UWWTD 2018). Used for the spill volume estimate.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecSturminster Newton WRC5 Jan 2025 11:51 GMT, 93 min5 Jan 2025 13:26 GMT, 6 h5 Jan 2025 19:26 GMT, 6 h6 Jan 2025 01:27 GMT, 18 h6 Jan 2025 19:30 GMT, 6 h7 Jan 2025 01:32 GMT, 6 h7 Jan 2025 07:32 GMT, 6 h7 Jan 2025 13:35 GMT, 6 h7 Jan 2025 19:36 GMT, 64 min26 Jan 2025 14:36 GMT, 50.9 h28 Jan 2025 17:29 GMT, 12 h29 Jan 2025 05:32 GMT, 6 h29 Jan 2025 11:33 GMT, 6 h29 Jan 2025 18:09 GMT, 29 min29 Jan 2025 18:41 GMT, 1 min24 Feb 2025 01:03 GMT, 24.9 h25 Feb 2025 01:58 GMT, 12 h25 Feb 2025 14:00 GMT, 6 h25 Feb 2025 20:01 GMT, 4.9 h26 Feb 2025 10:16 GMT, 3.3 h26 Feb 2025 13:36 GMT, 6 h26 Feb 2025 19:36 GMT, 6 h27 Feb 2025 01:42 GMT, 1 min27 Feb 2025 01:47 GMT, 65 min27 Feb 2025 08:11 GMT, 3.2 h27 Feb 2025 11:24 GMT, 3.8 h27 Feb 2025 15:13 GMT, 3 min5 Dec 2025 19:39 GMT, 2.5 h5 Dec 2025 22:09 GMT, 6 h6 Dec 2025 04:11 GMT, 6 h6 Dec 2025 10:12 GMT, 6 h6 Dec 2025 16:14 GMT, 11 min6 Dec 2025 16:29 GMT, 4 h9 Dec 2025 05:41 GMT, 8.1 h9 Dec 2025 13:45 GMT, 6 h9 Dec 2025 19:47 GMT, 6 h10 Dec 2025 01:48 GMT, 6 h10 Dec 2025 07:48 GMT, 6 h10 Dec 2025 13:50 GMT, 3.5 h10 Dec 2025 17:21 GMT, 2.5 h10 Dec 2025 19:52 GMT, 38 min15 Dec 2025 22:39 GMT, 7.8 h16 Dec 2025 06:27 GMT, 6 h16 Dec 2025 12:29 GMT, 6 h16 Dec 2025 18:29 GMT, 6 h18 Dec 2025 13:54 GMT, 23.4 h19 Dec 2025 13:21 GMT, 6 h19 Dec 2025 19:23 GMT, 6 h20 Dec 2025 01:25 GMT, 2 h20 Dec 2025 08:48 GMT, 1 min20 Dec 2025 08:51 GMT, 6 min20 Dec 2025 08:59 GMT, 4.4 h20 Dec 2025 13:27 GMT, 5 min20 Dec 2025 13:34 GMT, 1 min20 Dec 2025 13:48 GMT, 44 minSturminster Newton WRC5 Jan 2025 13:23 GMT, 3 min5 Jan 2025 19:24 GMT, 3 min6 Jan 2025 01:25 GMT, 3 min6 Jan 2025 03:06 GMT, 4 min6 Jan 2025 03:11 GMT, 4.4 h6 Jan 2025 07:34 GMT, 4.5 h6 Jan 2025 12:06 GMT, 3 min6 Jan 2025 12:12 GMT, 4 min6 Jan 2025 12:30 GMT, 1 min6 Jan 2025 12:36 GMT, 3 min6 Jan 2025 13:27 GMT, 3 min6 Jan 2025 19:28 GMT, 3 min7 Jan 2025 01:29 GMT, 2 min7 Jan 2025 07:30 GMT, 2 min7 Jan 2025 13:31 GMT, 2 min7 Jan 2025 19:32 GMT, 2 min24 Jan 2025 10:36 GMT, 1 min26 Jan 2025 14:48 GMT, 5 min26 Jan 2025 15:06 GMT, 4.2 h26 Jan 2025 19:16 GMT, 60 min26 Jan 2025 20:18 GMT, 14 min26 Jan 2025 20:36 GMT, 2 min26 Jan 2025 20:43 GMT, 1 min26 Jan 2025 20:48 GMT, 5 min26 Jan 2025 20:56 GMT, 4 min26 Jan 2025 21:03 GMT, 2 min26 Jan 2025 21:07 GMT, 38.4 h28 Jan 2025 11:35 GMT, 2.1 h28 Jan 2025 13:39 GMT, 4 min28 Jan 2025 13:45 GMT, 9 min28 Jan 2025 13:55 GMT, 4 min28 Jan 2025 14:00 GMT, 3 min28 Jan 2025 14:05 GMT, 3 min28 Jan 2025 14:10 GMT, 4 min28 Jan 2025 14:18 GMT, 9 min28 Jan 2025 14:32 GMT, 1 min28 Jan 2025 14:37 GMT, 2 min28 Jan 2025 14:43 GMT, 6 min28 Jan 2025 17:27 GMT, 3 min28 Jan 2025 23:28 GMT, 2 min29 Jan 2025 05:29 GMT, 2 min29 Jan 2025 11:30 GMT, 2 min29 Jan 2025 17:31 GMT, 2 min31 Jan 2025 10:37 GMT, 2 min24 Feb 2025 01:52 GMT, 3 min24 Feb 2025 03:26 GMT, 2 min24 Feb 2025 03:33 GMT, 3 min24 Feb 2025 03:45 GMT, 7 min24 Feb 2025 03:56 GMT, 3 min24 Feb 2025 04:03 GMT, 4 min24 Feb 2025 04:10 GMT, 8 min24 Feb 2025 04:21 GMT, 10 min24 Feb 2025 04:35 GMT, 3 min24 Feb 2025 04:39 GMT, 8 min24 Feb 2025 04:50 GMT, 9.2 h24 Feb 2025 14:01 GMT, 2.5 h24 Feb 2025 16:30 GMT, 4 min24 Feb 2025 16:41 GMT, 3 min24 Feb 2025 16:58 GMT, 2 min24 Feb 2025 19:55 GMT, 3 min25 Feb 2025 01:56 GMT, 3 min25 Feb 2025 07:57 GMT, 2 min25 Feb 2025 13:58 GMT, 2 min25 Feb 2025 19:59 GMT, 2 min26 Feb 2025 13:33 GMT, 4 min26 Feb 2025 19:34 GMT, 3 min27 Feb 2025 01:35 GMT, 2 min27 Feb 2025 11:20 GMT, 2 min10 Nov 2025 14:19 GMT, 2 min14 Nov 2025 20:12 GMT, 1 min5 Dec 2025 22:07 GMT, 3 min6 Dec 2025 04:07 GMT, 2 min6 Dec 2025 10:09 GMT, 2 min6 Dec 2025 16:09 GMT, 2 min9 Dec 2025 07:20 GMT, 28 min9 Dec 2025 07:54 GMT, 3 min9 Dec 2025 07:59 GMT, 43 min9 Dec 2025 08:44 GMT, 2 min9 Dec 2025 08:53 GMT, 5 min9 Dec 2025 09:08 GMT, 2 min9 Dec 2025 09:22 GMT, 5 min9 Dec 2025 09:31 GMT, 4 min9 Dec 2025 09:40 GMT, 4 min9 Dec 2025 10:00 GMT, 1 min9 Dec 2025 10:12 GMT, 1 min9 Dec 2025 13:43 GMT, 4 min9 Dec 2025 19:45 GMT, 2 min10 Dec 2025 01:45 GMT, 1 min10 Dec 2025 07:47 GMT, 2 min10 Dec 2025 13:48 GMT, 1 min10 Dec 2025 19:48 GMT, 1 min16 Dec 2025 00:24 GMT, 3 min16 Dec 2025 06:24 GMT, 3 min16 Dec 2025 12:26 GMT, 2 min16 Dec 2025 18:27 GMT, 2 min17 Dec 2025 00:29 GMT, 1 min18 Dec 2025 13:14 GMT, 5 min18 Dec 2025 14:08 GMT, 12.7 h19 Dec 2025 02:57 GMT, 7 min19 Dec 2025 03:06 GMT, 7 min19 Dec 2025 03:18 GMT, 5 min19 Dec 2025 03:33 GMT, 1 min19 Dec 2025 07:18 GMT, 3 min19 Dec 2025 13:20 GMT, 2 min19 Dec 2025 19:21 GMT, 2 min20 Dec 2025 01:21 GMT, 1 min20 Dec 2025 07:23 GMT, 1 min20 Dec 2025 13:23 GMT, 1 min21 Dec 2025 20:55 GMT, 2 min22 Dec 2025 02:55 GMT, 1 min22 Dec 2025 12:42 GMT, 1 min

Estimated spill volume by month, 2025

Hours spilling each month × the estimated spill rate for a works of this size. The bars are central estimates and the whiskers show the low–high range. Method.

020k40k60kJan 2025: 189 h spilling ≈ 22,144 m³ (range 8,820–55,593 m³)JanFeb 2025: 84 h spilling ≈ 9,891 m³ (range 3,940–24,832 m³)FebMar 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)MarApr 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)AprMay 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)MayJun 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)JunJul 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)JulAug 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)AugSep 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)SepOct 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)OctNov 2025: 0.1 h spilling ≈ 12 m³ (range 4.7–29 m³)NovDec 2025: 147 h spilling ≈ 17,292 m³ (range 6,888–43,413 m³)Dec
Cubic metres (m³), estimate. Hours are measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDurationEstimated volume
26 Jan 2025, 14:36Sturminster Newton WRC2.1 days2,380 – 15,002 m³
26 Jan 2025, 21:07Sturminster Newton WRC1.6 days1,797 – 11,325 m³
24 Feb 2025, 01:03Sturminster Newton WRC1.0 days1,165 – 7,344 m³
18 Dec 2025, 13:54Sturminster Newton WRC23.4 h1,096 – 6,906 m³
6 Jan 2025, 01:27Sturminster Newton WRC18.0 h844 – 5,318 m³

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

Volume, central estimate49,327 m³range 19,648 – 123,838 m³
In litres49.3 millionrange 19.6 million – 123.8 million L
Olympic swimming pools20at 2,500 m³ each
Organic load, as people's raw sewage73,991person-days of untreated BOD

Assumed spill rate while spilling: 13.0 – 81.9 L/s (central 32.6 L/s), from a dry-weather flow of 13.0 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 786 kg4,439 kg24,768 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 2,063 kg20,964 kg89,287 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 37 kg311 kg1,152 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3–9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 24 kg128 kg669 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 2.0 trillion organisms49.3 trillion organisms1.2 × 10¹⁵ organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Sturminster Newton WRC

Storm tank at sewage works · discharges to River Stour

Spills 2025
22 (335 hours) · down 44% on 2024
Spills 2024
39 (569 hours)
Long-term average
30.7 spills a year (monitored since 2023)
Monitor uptime
100% of the year
Investigation
No investigation activity in reporting period
Improvement
No improvement action in reporting period
WFD catchment
Stour (Middle u/s Pimperne Brook) (GB108043016051)
Outlet location
ST7996413981 (OS grid reference) · View on Apple Maps
EA ID / permit
WXW01084 · NPSWQD008026 · company name: STURMINSTER NEWTON OPP RIXON CLOSE STORM TANK

Sturminster Newton WRC

Inlet overflow at sewage works · discharges to River Stour

Spills 2025
26 (85 hours) · down 26% on 2024
Spills 2024
35 (46 hours)
Long-term average
26.7 spills a year (monitored since 2023)
Monitor uptime
100% of the year
Investigation
No investigation activity in reporting period
Improvement
No improvement action in reporting period
WFD catchment
Stour (Middle u/s Pimperne Brook) (GB108043016051)
Outlet location
ST7996413981 (OS grid reference) · View on Apple Maps
EA ID / permit
WXW01083 · NPSWQD008026 · company name: STURMINSTER NEWTON OPP RIXON CLOSE INLET

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024–25 [EA]. Infiltration of groundwater into sewers is taken as 0–40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies – environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 – per capita consumption
  3. HBF: Foul sewer design – historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 – CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Wessex Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.