Storm overflow register · Wessex Water

Tetbury sewage works: storm overflow spills 2025

Tetbury sewage treatment works, run by Wessex Water, has 2 monitored storm overflows discharging to River Avon. In 2025 they recorded 127 spills totalling 1,648 hours, against 186 spills and 2,698 hours in 2024. By hours spilling, it ranks 10 of 242 Wessex Water works, where 1 spilled longest.

Works size: 6,326 population equivalent (TETBURY STW, UWWTD 2018). Used for the spill volume estimate.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecTetbury Waste Water…1 Jan 2025 12:30 GMT, 2 h28 spills, 122.8 h, 5 Jan to 12 Jan13 spills, 199.3 h, 26 Jan to 4 Feb68 spills, 65.1 h, 23 Feb to 1 Mar2 spills, 3.9 h, 14 Sep to 14 Sep24 Oct 2025 19:43 GMT, 86 min180 spills, 1100.7 h, 11 Nov to 31 DecTetbury Waste Water…19 spills, 10 h, 5 Jan to 6 Jan4 spills, 4.8 h, 26 Jan to 27 Jan28 Jan 2025 09:19 GMT, 38 min31 Jan 2025 04:37 GMT, 26 min5 Feb 2025 09:57 GMT, 18 min3 spills, 0.6 h, 23 Feb to 23 Feb4 spills, 0.2 h, 25 Feb to 25 Feb14 spills, 4.4 h, 26 Feb to 26 Feb23 Apr 2025 00:29 GMT, 1 min3 Jun 2025 10:47 GMT, 15 min12 Jun 2025 12:13 GMT, 63 min27 Aug 2025 15:54 GMT, 45 min31 Aug 2025 14:44 GMT, 1 min4 Sep 2025 07:02 GMT, 13 min2 spills, 0.6 h, 7 Sep to 7 Sep8 Sep 2025 16:07 GMT, 16 min2 spills, 0.8 h, 11 Sep to 11 Sep4 spills, 1.3 h, 14 Sep to 14 Sep19 Oct 2025 15:53 GMT, 1 min2 spills, 0.6 h, 20 Oct to 20 Oct4 spills, 1 h, 24 Oct to 24 Oct31 Oct 2025 12:22 GMT, 29 min10 Nov 2025 02:10 GMT, 12 min3 spills, 2.7 h, 11 Nov to 12 Nov33 spills, 49.3 h, 13 Nov to 16 Nov20 Nov 2025 14:39 GMT, 43 min3 spills, 1 h, 22 Nov to 23 Nov28 Nov 2025 10:11 GMT, 27 min13 spills, 4.7 h, 1 Dec to 1 Dec4 Dec 2025 07:47 GMT, 36 min2 spills, 1.1 h, 5 Dec to 5 Dec2 spills, 1.6 h, 7 Dec to 7 Dec25 spills, 15.6 h, 9 Dec to 10 Dec37 spills, 13 h, 15 Dec to 16 Dec71 spills, 33.1 h, 17 Dec to 20 Dec

Estimated spill volume by month, 2025

Hours spilling each month × the estimated spill rate for a works of this size. The bars are central estimates and the whiskers show the low-high range. Method.

0100k200k300kJan 2025: 269 h spilling ≈ 29,190 m³ (range 11,627-73,283 m³)JanFeb 2025: 137 h spilling ≈ 14,882 m³ (range 5,928-37,363 m³)FebMar 2025: 3.7 h spilling ≈ 401 m³ (range 160-1,007 m³)MarApr 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0-0.0 m³)AprMay 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0-0.0 m³)MayJun 2025: 1.3 h spilling ≈ 141 m³ (range 56-354 m³)JunJul 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0-0.0 m³)JulAug 2025: 0.8 h spilling ≈ 87 m³ (range 35-218 m³)AugSep 2025: 7.1 h spilling ≈ 770 m³ (range 307-1,932 m³)SepOct 2025: 3.5 h spilling ≈ 379 m³ (range 151-952 m³)OctNov 2025: 461 h spilling ≈ 49,926 m³ (range 19,886-125,340 m³)NovDec 2025: 764 h spilling ≈ 82,823 m³ (range 32,990-207,930 m³)Dec
Cubic metres (m³), estimate. Hours are measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDurationEstimated volume
1 Dec 2025, 05:33Tetbury Waste Water Treatment Works25.9 days26,787 - 168,834 m³
13 Nov 2025, 14:44Tetbury Waste Water Treatment Works6.9 days7,137 - 44,982 m³
26 Jan 2025, 15:15Tetbury Waste Water Treatment Works5.4 days5,559 - 35,036 m³
5 Jan 2025, 10:00Tetbury Waste Water Treatment Works3.7 days3,789 - 23,879 m³
22 Nov 2025, 08:03Tetbury Waste Water Treatment Works3.1 days3,263 - 20,563 m³

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

Volume, central estimate178,598 m³range 71,139 - 448,378 m³
In litres178.6 millionrange 71.1 million - 448.4 million L
Olympic swimming pools71at 2,500 m³ each
Organic load, as people's raw sewage267,897person-days of untreated BOD

Assumed spill rate while spilling: 12.0 - 75.6 L/s (central 30.1 L/s), from a dry-weather flow of 12.0 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 2,846 kg16,074 kg89,676 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 7,470 kg75,904 kg323,280 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 135 kg1,125 kg4,170 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3-9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 85 kg464 kg2,421 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 7.1 trillion organisms178.6 trillion organisms4.5 × 10¹⁵ organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Tetbury Waste Water Treatment Works

Storm tank at sewage works · discharges to River Avon

Spills 2025
78 (1,495 hours) · down 43% on 2024
Spills 2024
137 (2,519 hours)
Long-term average
88.7 spills a year (monitored since 2019)
Monitor uptime
99% of the year
High-spill reason (company)
Not Applicable - Ongoing investigation
Investigation
Operational investigation completed
Improvement
Operational improvement completed
WFD catchment
Tetbury Avon - source to conf unnamed trib (GB109053027800)
Outlet location
ST8954892447 (OS grid reference) · View on Apple Maps
EA ID / permit
WXW01112 · 102818 · company name: TETBURY STORM TANK

Tetbury Waste Water Treatment Works

Inlet overflow at sewage works · discharges to River Avon

Spills 2025
49 (153 hours) · no change on 2024
Spills 2024
49 (180 hours)
Long-term average
79.9 spills a year (monitored since 2019)
Monitor uptime
99% of the year
High-spill reason (company)
Not Applicable - Ongoing investigation
Investigation
Operational investigation completed
Improvement
Operational improvement completed
WFD catchment
Tetbury Avon - source to conf unnamed trib (GB109053027800)
Outlet location
ST8942892804 (OS grid reference) · View on Apple Maps
EA ID / permit
WXW01111 · 102818 · company name: TETBURY INLET

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024-25 [EA]. Infiltration of groundwater into sewers is taken as 0-40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies - environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 - per capita consumption
  3. HBF: Foul sewer design - historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 - CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Wessex Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.