Storm overflow register · Yorkshire Water

Bainbridge sewage works: storm overflow spills 2025

Bainbridge sewage treatment works, run by Yorkshire Water, has 1 monitored storm overflow discharging to River Bain. In 2025 it recorded 64 spills totalling 139 hours, against 77 spills and 325 hours in 2024. By hours spilling, it ranks 200 of 283 Yorkshire Water works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecBainbridge STW1 Jan 2025 00:00 GMT, 13 h24 Jan 2025 02:15 GMT, 2.3 h24 Jan 2025 05:15 GMT, 15 min24 Jan 2025 06:15 GMT, 15 min27 Jan 2025 03:00 GMT, 2 h28 Jan 2025 00:30 GMT, 30 min20 Feb 2025 13:00 GMT, 60 min21 Feb 2025 16:30 GMT, 30 min21 Feb 2025 18:15 GMT, 15 min23 Feb 2025 10:30 GMT, 60 min23 Feb 2025 13:30 GMT, 45 min23 Feb 2025 14:45 GMT, 15 min23 Feb 2025 15:15 GMT, 30 min23 Feb 2025 16:00 GMT, 15 min23 Feb 2025 19:15 GMT, 60 min23 Feb 2025 20:30 GMT, 30 min23 Feb 2025 23:15 GMT, 15 min24 Feb 2025 00:00 GMT, 60 min24 Feb 2025 01:30 GMT, 30 min24 Feb 2025 20:30 GMT, 15 min12 Mar 2025 11:45 GMT, 45 min22 Mar 2025 17:45 GMT, 30 min26 May 2025 22:00 GMT, 15 min1 Jun 2025 11:15 GMT, 30 min3 Jun 2025 06:45 GMT, 15 min6 Jun 2025 06:45 GMT, 45 min6 Jun 2025 07:45 GMT, 30 min7 Jun 2025 05:00 GMT, 15 min7 Jun 2025 05:30 GMT, 45 min7 Jun 2025 06:30 GMT, 2.3 h7 Jun 2025 19:15 GMT, 30 min9 Jun 2025 20:45 GMT, 2.3 h9 Jun 2025 23:15 GMT, 15 min21 Jun 2025 19:15 GMT, 15 min22 Jun 2025 20:45 GMT, 15 min2 Jul 2025 00:15 GMT, 15 min2 Jul 2025 00:45 GMT, 30 min6 Jul 2025 03:45 GMT, 90 min6 Jul 2025 05:30 GMT, 15 min6 Jul 2025 06:00 GMT, 15 min7 Jul 2025 22:00 GMT, 15 min15 Jul 2025 14:15 GMT, 30 min15 Jul 2025 16:30 GMT, 2.8 h19 Jul 2025 14:00 GMT, 30 min19 Jul 2025 14:45 GMT, 15 min20 Jul 2025 15:15 GMT, 15 min4 Aug 2025 07:45 GMT, 30 min4 Aug 2025 08:45 GMT, 30 min4 Aug 2025 09:30 GMT, 15 min4 Aug 2025 11:15 GMT, 15 min5 Aug 2025 08:30 GMT, 15 min1 Sep 2025 12:00 GMT, 15 min1 Sep 2025 22:45 GMT, 30 min11 Sep 2025 10:15 GMT, 30 min12 Sep 2025 22:00 GMT, 30 min13 Sep 2025 20:15 GMT, 30 min15 Sep 2025 05:00 GMT, 15 min15 Sep 2025 06:45 GMT, 15 min15 Sep 2025 08:00 GMT, 30 min15 Sep 2025 08:45 GMT, 15 min15 Sep 2025 09:15 GMT, 15 min15 Sep 2025 09:45 GMT, 60 min15 Sep 2025 11:15 GMT, 15 min15 Sep 2025 19:00 GMT, 30 min15 Sep 2025 19:45 GMT, 30 min15 Sep 2025 21:45 GMT, 45 min16 Sep 2025 01:30 GMT, 45 min20 Sep 2025 05:45 GMT, 2 h20 Sep 2025 08:30 GMT, 15 min20 Sep 2025 10:00 GMT, 15 min20 Sep 2025 11:00 GMT, 15 min20 Sep 2025 12:00 GMT, 15 min20 Sep 2025 13:00 GMT, 15 min20 Sep 2025 13:30 GMT, 45 min20 Sep 2025 14:30 GMT, 30 min20 Sep 2025 15:45 GMT, 15 min20 Sep 2025 16:15 GMT, 12.3 h21 Sep 2025 05:30 GMT, 15 min21 Sep 2025 06:15 GMT, 15 min21 Sep 2025 08:30 GMT, 15 min21 Sep 2025 17:45 GMT, 15 min2 Oct 2025 21:30 GMT, 45 min3 Oct 2025 00:30 GMT, 30 min3 Oct 2025 02:45 GMT, 30 min3 Oct 2025 13:15 GMT, 7.5 h4 Oct 2025 12:30 GMT, 30 min4 Oct 2025 13:45 GMT, 30 min26 Oct 2025 20:15 GMT, 15 min27 Oct 2025 23:45 GMT, 30 min29 Oct 2025 00:15 GMT, 15 min29 Oct 2025 20:15 GMT, 15 min1 Nov 2025 07:00 GMT, 45 min1 Nov 2025 18:45 GMT, 15 min3 Nov 2025 18:45 GMT, 90 min3 Nov 2025 20:30 GMT, 15 min3 Nov 2025 22:15 GMT, 15 min3 Nov 2025 22:45 GMT, 30 min3 Nov 2025 23:45 GMT, 45 min4 Nov 2025 00:45 GMT, 30 min4 Nov 2025 02:15 GMT, 30 min4 Nov 2025 04:45 GMT, 75 min4 Nov 2025 06:15 GMT, 45 min4 Nov 2025 07:15 GMT, 15 min4 Nov 2025 08:00 GMT, 75 min4 Nov 2025 09:45 GMT, 15 min4 Nov 2025 11:30 GMT, 30 min5 Nov 2025 08:45 GMT, 15 min11 Nov 2025 10:00 GMT, 15 min11 Nov 2025 20:15 GMT, 60 min11 Nov 2025 21:45 GMT, 15 min12 Nov 2025 21:30 GMT, 30 min12 Nov 2025 22:30 GMT, 15 min13 Nov 2025 02:15 GMT, 15 min13 Nov 2025 02:45 GMT, 30 min13 Nov 2025 03:30 GMT, 15 min13 Nov 2025 05:00 GMT, 15 min13 Nov 2025 11:15 GMT, 45 min23 Nov 2025 06:00 GMT, 30 min23 Nov 2025 13:30 GMT, 15 min23 Nov 2025 14:30 GMT, 60 min23 Nov 2025 16:45 GMT, 15 min24 Nov 2025 09:00 GMT, 15 min24 Nov 2025 09:30 GMT, 15 min27 Nov 2025 17:15 GMT, 15 min28 Nov 2025 12:00 GMT, 45 min28 Nov 2025 13:15 GMT, 30 min28 Nov 2025 14:15 GMT, 15 min1 Dec 2025 05:15 GMT, 75 min1 Dec 2025 07:00 GMT, 2.3 h1 Dec 2025 09:30 GMT, 30 min1 Dec 2025 10:30 GMT, 15 min1 Dec 2025 11:00 GMT, 15 min1 Dec 2025 11:30 GMT, 15 min1 Dec 2025 12:30 GMT, 15 min1 Dec 2025 13:00 GMT, 15 min1 Dec 2025 14:30 GMT, 15 min1 Dec 2025 15:15 GMT, 15 min1 Dec 2025 16:15 GMT, 30 min1 Dec 2025 17:45 GMT, 15 min1 Dec 2025 18:30 GMT, 15 min1 Dec 2025 19:00 GMT, 15 min1 Dec 2025 20:00 GMT, 45 min1 Dec 2025 21:00 GMT, 15 min1 Dec 2025 21:45 GMT, 15 min1 Dec 2025 22:15 GMT, 15 min1 Dec 2025 23:45 GMT, 30 min5 Dec 2025 17:30 GMT, 60 min5 Dec 2025 18:45 GMT, 60 min5 Dec 2025 20:00 GMT, 30 min5 Dec 2025 20:45 GMT, 30 min5 Dec 2025 22:00 GMT, 45 min6 Dec 2025 13:00 GMT, 15 min6 Dec 2025 13:45 GMT, 15 min6 Dec 2025 14:15 GMT, 15 min6 Dec 2025 18:30 GMT, 45 min6 Dec 2025 21:15 GMT, 15 min7 Dec 2025 16:45 GMT, 30 min7 Dec 2025 17:30 GMT, 30 min8 Dec 2025 06:30 GMT, 15 min8 Dec 2025 07:00 GMT, 15 min8 Dec 2025 17:45 GMT, 60 min9 Dec 2025 04:45 GMT, 4 h9 Dec 2025 09:30 GMT, 30 min9 Dec 2025 10:15 GMT, 4.3 h9 Dec 2025 15:30 GMT, 15 min9 Dec 2025 16:30 GMT, 15 min9 Dec 2025 17:45 GMT, 15 min9 Dec 2025 18:45 GMT, 15 min9 Dec 2025 19:15 GMT, 15 min9 Dec 2025 20:00 GMT, 15 min10 Dec 2025 02:45 GMT, 30 min10 Dec 2025 03:30 GMT, 30 min10 Dec 2025 05:15 GMT, 15 min10 Dec 2025 06:15 GMT, 15 min10 Dec 2025 08:00 GMT, 45 min10 Dec 2025 09:00 GMT, 15 min10 Dec 2025 09:30 GMT, 15 min10 Dec 2025 10:30 GMT, 15 min10 Dec 2025 11:15 GMT, 15 min10 Dec 2025 12:00 GMT, 30 min10 Dec 2025 12:45 GMT, 15 min10 Dec 2025 13:15 GMT, 90 min10 Dec 2025 18:30 GMT, 15 min17 Dec 2025 18:15 GMT, 30 min17 Dec 2025 19:45 GMT, 75 min17 Dec 2025 21:45 GMT, 30 min17 Dec 2025 22:30 GMT, 90 min18 Dec 2025 00:15 GMT, 15 min18 Dec 2025 02:00 GMT, 45 min18 Dec 2025 03:00 GMT, 15 min

Hours spilling by month, 2025

010203040Jan 2025: 18 hours spillingJanFeb 2025: 8.0 hours spillingFebMar 2025: 1.2 hours spillingMarApr 2025: 0.0 hours spillingAprMay 2025: 0.2 hours spillingMayJun 2025: 8.8 hours spillingJunJul 2025: 7.2 hours spillingJulAug 2025: 1.8 hours spillingAugSep 2025: 26 hours spillingSepOct 2025: 12 hours spillingOctNov 2025: 18 hours spillingNovDec 2025: 38 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
1 Jan 2025, 00:00Bainbridge STW13.0 h
20 Sep 2025, 16:15Bainbridge STW12.3 h
3 Oct 2025, 13:15Bainbridge STW7.5 h
9 Dec 2025, 10:15Bainbridge STW4.3 h
9 Dec 2025, 04:45Bainbridge STW4.0 h

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate2,378 m³range 947 – 5,971 m³
In litres2.4 millionrange 947,310 – 6.0 million L
Olympic swimming pools1.0at 2,500 m³ each
Organic load, as people's raw sewage3,567person-days of untreated BOD

Assumed spill rate while spilling: 1.9 – 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 38 kg214 kg1,194 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 99 kg1,011 kg4,305 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 1.8 kg15 kg56 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3–9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 1.1 kg6.2 kg32 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 94.7 billion organisms2.4 trillion organisms59.7 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Bainbridge STW

Inlet overflow at sewage works · discharges to River Bain

Spills 2025
64 (139 hours) · down 17% on 2024
Spills 2024
77 (325 hours)
Long-term average
78.2 spills a year (monitored since 2020)
Monitor uptime
100% of the year
High-spill reason (company)
Performance - SW Infiltration
Investigation
UWWTR investigation ongoing, Operational investigation completed
Improvement
Operational improvement completed
WFD catchment
River Bain/Raydale Beck Catch (trib of Ure) (GB104027069400)
Outlet location
SD9349090510 (OS grid reference) · View on Apple Maps
EA ID / permit
YWS00311 · 27/22/0121 · company name: BAINBRIDGE/STW

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024–25 [EA]. Infiltration of groundwater into sewers is taken as 0–40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies – environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 – per capita consumption
  3. HBF: Foul sewer design – historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 – CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Yorkshire Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.