Storm overflow register · Yorkshire Water

Eastwood sewage works: storm overflow spills 2025

Eastwood sewage treatment works, run by Yorkshire Water, has 2 monitored storm overflows discharging to River Calder. In 2025 they recorded 225 spills totalling 2,988 hours, against 239 spills and 2,851 hours in 2024. By hours spilling, it ranks 2 of 283 Yorkshire Water works, where 1 spilled longest.

Works size: 15,425 population equivalent (TODMORDEN STW, UWWTD 2018). Used for the spill volume estimate.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecEastwood WwTW23 spills, 322.5 h, 1 Jan to 16 Jan8 spills, 17.5 h, 23 Jan to 25 Jan7 spills, 59 h, 27 Jan to 29 Jan31 Jan 2025 03:45 GMT, 3 h20 Feb 2025 16:00 GMT, 2.8 h23 Feb 2025 18:45 GMT, 8.8 h24 Feb 2025 22:15 GMT, 30 min2 spills, 6.8 h, 26 Feb to 26 Feb2 spills, 8.5 h, 26 May to 27 May29 May 2025 05:00 GMT, 8 h3 spills, 9.3 h, 3 Jun to 3 Jun2 spills, 4.8 h, 5 Jun to 6 Jun2 spills, 11 h, 10 Jun to 10 Jun2 spills, 7 h, 15 Jul to 15 Jul19 Jul 2025 15:30 GMT, 15 min2 spills, 6 h, 20 Jul to 20 Jul4 Aug 2025 11:45 GMT, 3.3 h4 Sep 2025 04:30 GMT, 75 min10 Sep 2025 21:00 GMT, 75 min12 Sep 2025 07:00 GMT, 3.3 h6 spills, 53.8 h, 13 Sep to 17 Sep20 Sep 2025 07:45 GMT, 63 h28 Sep 2025 00:45 GMT, 6.3 h2 spills, 88.3 h, 2 Oct to 6 Oct24 spills, 725.8 h, 19 Oct to 21 Nov15 spills, 760.3 h, 22 Nov to 25 DecEastwood NO2 CSO4 spills, 63.8 h, 1 Jan to 4 Jan5 Jan 2025 15:45 GMT, 59 h2 spills, 2.8 h, 23 Jan to 24 Jan3 spills, 19.8 h, 27 Jan to 28 Jan20 Feb 2025 14:00 GMT, 2.5 h23 Feb 2025 18:00 GMT, 5.5 h2 spills, 1.3 h, 26 Feb to 26 Feb22 Mar 2025 21:45 GMT, 30 min26 May 2025 18:30 GMT, 6 h29 May 2025 06:00 GMT, 15 min3 Jun 2025 05:45 GMT, 3.3 h2 spills, 2.3 h, 5 Jun to 6 Jun8 Jun 2025 13:00 GMT, 45 min9 Jun 2025 22:45 GMT, 6 h22 Jun 2025 19:30 GMT, 2.8 h2 spills, 4.5 h, 15 Jul to 15 Jul19 Jul 2025 13:15 GMT, 75 min20 Jul 2025 12:15 GMT, 3.3 h4 Aug 2025 10:15 GMT, 3.3 h3 Sep 2025 03:00 GMT, 30 min4 Sep 2025 02:45 GMT, 90 min7 Sep 2025 14:00 GMT, 45 min8 Sep 2025 16:30 GMT, 45 min10 Sep 2025 19:15 GMT, 105 min12 Sep 2025 06:00 GMT, 2 h13 Sep 2025 22:15 GMT, 90 min3 spills, 17.3 h, 15 Sep to 16 Sep17 Sep 2025 05:00 GMT, 8.8 h2 spills, 34.5 h, 20 Sep to 21 Sep27 Sep 2025 22:45 GMT, 3.3 h3 spills, 41.8 h, 2 Oct to 5 Oct2 spills, 17 h, 19 Oct to 20 Oct2 spills, 2.5 h, 21 Oct to 21 Oct2 spills, 6 h, 24 Oct to 25 Oct2 spills, 10 h, 26 Oct to 27 Oct2 spills, 6.8 h, 29 Oct to 30 Oct31 Oct 2025 01:15 GMT, 75 min1 Nov 2025 07:45 GMT, 7.3 h5 spills, 52 h, 3 Nov to 5 Nov2 spills, 2.3 h, 9 Nov to 9 Nov6 spills, 19.8 h, 11 Nov to 13 Nov3 spills, 46.3 h, 14 Nov to 16 Nov3 spills, 7.3 h, 18 Nov to 19 Nov22 Nov 2025 04:45 GMT, 2.3 h2 spills, 24.5 h, 23 Nov to 24 Nov28 Nov 2025 12:45 GMT, 2.8 h29 Nov 2025 12:45 GMT, 12 h1 Dec 2025 02:15 GMT, 48 h4 Dec 2025 11:00 GMT, 8.8 h4 spills, 128 h, 5 Dec to 12 Dec15 Dec 2025 02:15 GMT, 38 h17 Dec 2025 16:30 GMT, 56.3 h21 Dec 2025 22:30 GMT, 4.8 h

Estimated spill volume by month, 2025

Hours spilling each month × the estimated spill rate for a works of this size. The bars are central estimates and the whiskers show the low-high range. Method.

0200k400k600kJan 2025: 547 h spilling ≈ 144,624 m³ (range 57,607-363,085 m³)JanFeb 2025: 28 h spilling ≈ 7,400 m³ (range 2,948-18,579 m³)FebMar 2025: 0.5 h spilling ≈ 132 m³ (range 53-332 m³)MarApr 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0-0.0 m³)AprMay 2025: 23 h spilling ≈ 6,000 m³ (range 2,390-15,062 m³)MayJun 2025: 40 h spilling ≈ 10,572 m³ (range 4,211-26,541 m³)JunJul 2025: 22 h spilling ≈ 5,867 m³ (range 2,337-14,730 m³)JulAug 2025: 6.4 h spilling ≈ 1,692 m³ (range 674-4,247 m³)AugSep 2025: 201 h spilling ≈ 53,203 m³ (range 21,192-133,569 m³)SepOct 2025: 442 h spilling ≈ 116,741 m³ (range 46,500-293,082 m³)OctNov 2025: 822 h spilling ≈ 217,253 m³ (range 86,537-545,423 m³)NovDec 2025: 856 h spilling ≈ 226,187 m³ (range 90,095-567,851 m³)Dec
Cubic metres (m³), estimate. Hours are measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDurationEstimated volume
29 Nov 2025, 07:30Eastwood WwTW24.9 days62,797 - 395,797 m³
1 Jan 2025, 09:00Eastwood WwTW9.8 days24,634 - 155,267 m³
11 Nov 2025, 19:45Eastwood WwTW9.2 days23,187 - 146,143 m³
1 Nov 2025, 06:15Eastwood WwTW7.8 days19,765 - 124,578 m³
26 Oct 2025, 11:45Eastwood WwTW5.6 days14,265 - 89,909 m³

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

Volume, central estimate789,724 m³range 314,564 - 2.0 million m³
In litres789.7 millionrange 314.6 million - 2.0 billion L
Olympic swimming pools316at 2,500 m³ each
Organic load, as people's raw sewage1.2 millionperson-days of untreated BOD

Assumed spill rate while spilling: 29.2 - 184.3 L/s (central 73.4 L/s), from a dry-weather flow of 29.2 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 12,583 kg71,075 kg396,527 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 33,029 kg335,633 kg1.4 million kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 598 kg4,975 kg18,438 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3-9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 377 kg2,053 kg10,706 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 31.5 trillion organisms789.7 trillion organisms2.0 × 10¹⁶ organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Eastwood WwTW

Storm tank at sewage works · discharges to River Calder

Spills 2025
129 (2,182 hours) · down 7% on 2024
Spills 2024
138 (1,981 hours)
Long-term average
135.5 spills a year (monitored since 2020)
Monitor uptime
100% of the year
High-spill reason (company)
Not asset maintenance - hydraulic capacity
Investigation
UWWTR investigation ongoing, Operational investigation ongoing
Improvement
No improvement action in reporting period
WFD catchment
Calder from Walsden Water to Colden Water (GB104027062650)
Outlet location
SD9716026380 (OS grid reference) · View on Apple Maps
EA ID / permit
YWS00910 · E61 · company name: EASTWOOD/STW

Eastwood NO2 CSO

Inlet overflow at sewage works · discharges to River Calder

Spills 2025
96 (806 hours) · down 5% on 2024
Spills 2024
101 (871 hours)
Long-term average
89.7 spills a year (monitored since 2020)
Monitor uptime
100% of the year
High-spill reason (company)
Not asset maintenance - hydraulic capacity
Investigation
UWWTR investigation ongoing, Operational investigation completed
Improvement
No improvement action in reporting period
WFD catchment
Calder from Walsden Water to Colden Water (GB104027062650)
Outlet location
SD9715126413 (OS grid reference) · View on Apple Maps
EA ID / permit
YWS01030 · NPSWQD011063 · company name: EASTWOOD/NO 2 CSO

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024-25 [EA]. Infiltration of groundwater into sewers is taken as 0-40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies - environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 - per capita consumption
  3. HBF: Foul sewer design - historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 - CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Yorkshire Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.