Storm overflow register · Yorkshire Water

Hemingbrough Wpc Works sewage works: storm overflow spills 2025

Hemingbrough Wpc Works sewage treatment works, run by Yorkshire Water, has 1 monitored storm overflow discharging to River Ouse (Tidal). In 2025 it recorded 26 spills totalling 113 hours, against 26 spills and 121 hours in 2024. By hours spilling, it ranks 207 of 283 Yorkshire Water works, where 1 spilled longest.

Works size: 2,225 population equivalent (HEMINGBROUGH STW, UWWTD 2018). Used for the spill volume estimate.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecHemingbrough Wpc Works27 spills, 8.3 h, 1 Jan to 1 Jan28 spills, 36.8 h, 5 Jan to 7 Jan8 Jan 2025 22:15 GMT, 15 min19 Jul 2025 15:15 GMT, 3.8 h3 spills, 4.8 h, 20 Jul to 20 Jul13 spills, 7 h, 20 Sep to 21 Sep21 spills, 7.8 h, 14 Nov to 15 Nov51 spills, 19.5 h, 29 Nov to 1 Dec5 spills, 1.3 h, 4 Dec to 4 Dec7 spills, 1.8 h, 5 Dec to 6 Dec3 spills, 0.8 h, 7 Dec to 7 Dec22 spills, 7.5 h, 9 Dec to 9 Dec18 spills, 4.5 h, 15 Dec to 16 Dec20 spills, 8.8 h, 17 Dec to 19 Dec

Estimated spill volume by month, 2025

Hours spilling each month × the estimated spill rate for a works of this size. The bars are central estimates and the whiskers show the low-high range. Method.

02,0004,0006,000Jan 2025: 45 h spilling ≈ 1,723 m³ (range 686-4,326 m³)JanFeb 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0-0.0 m³)FebMar 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0-0.0 m³)MarApr 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0-0.0 m³)AprMay 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0-0.0 m³)MayJun 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0-0.0 m³)JunJul 2025: 8.5 h spilling ≈ 324 m³ (range 129-814 m³)JulAug 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0-0.0 m³)AugSep 2025: 7.0 h spilling ≈ 267 m³ (range 106-670 m³)SepOct 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0-0.0 m³)OctNov 2025: 25 h spilling ≈ 934 m³ (range 372-2,345 m³)NovDec 2025: 27 h spilling ≈ 1,037 m³ (range 413-2,603 m³)Dec
Cubic metres (m³), estimate. Hours are measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDurationEstimated volume
5 Jan 2025, 16:30Hemingbrough Wpc Works1.3 days456 - 2,871 m³
29 Nov 2025, 19:00Hemingbrough Wpc Works4.8 h72 - 455 m³
20 Jul 2025, 13:45Hemingbrough Wpc Works4.3 h65 - 407 m³
18 Dec 2025, 14:45Hemingbrough Wpc Works4.0 h61 - 383 m³
19 Jul 2025, 15:15Hemingbrough Wpc Works3.8 h57 - 359 m³

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

Volume, central estimate4,289 m³range 1,708 - 10,768 m³
In litres4.3 millionrange 1.7 million - 10.8 million L
Olympic swimming pools1.7at 2,500 m³ each
Organic load, as people's raw sewage6,433person-days of untreated BOD

Assumed spill rate while spilling: 4.2 - 26.6 L/s (central 10.6 L/s), from a dry-weather flow of 4.2 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 68 kg386 kg2,154 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 179 kg1,823 kg7,763 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 3.2 kg27 kg100 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3-9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 2.1 kg11 kg58 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 170.8 billion organisms4.3 trillion organisms107.7 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Hemingbrough Wpc Works

Storm tank at sewage works · discharges to River Ouse (Tidal)

Spills 2025
26 (113 hours) · no change on 2024
Spills 2024
26 (121 hours)
Long-term average
23.3 spills a year (monitored since 2020)
Monitor uptime
100% of the year
Investigation
UWWTR investigation ongoing, Operational investigation completed
Improvement
No improvement action in reporting period
WFD catchment
Ouse from R Wharfe to Upper Humber (GB104027064270)
Outlet location
SE6689030040 (OS grid reference) · View on Apple Maps
EA ID / permit
YWS00390 · 27/24/0168 · company name: HEMINGBROUGH/NO 2 STW

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024-25 [EA]. Infiltration of groundwater into sewers is taken as 0-40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies - environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 - per capita consumption
  3. HBF: Foul sewer design - historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 - CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Yorkshire Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.