Storm overflow register · Yorkshire Water

Hunton Final Effluent sewage works: storm overflow spills 2025

Hunton Final Effluent sewage treatment works, run by Yorkshire Water, has 1 monitored storm overflow discharging to Hunton Beck. In 2025 it recorded 63 spills totalling 501 hours, against 73 spills and 692 hours in 2024. By hours spilling, it ranks 90 of 283 Yorkshire Water works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecHunton STW Final…1 Jan 2025 00:00 GMT, 25.8 h2 Jan 2025 02:00 GMT, 30 min2 Jan 2025 03:30 GMT, 2.3 h2 Jan 2025 06:15 GMT, 15 min2 Jan 2025 06:45 GMT, 60 min2 Jan 2025 08:15 GMT, 30 min2 Jan 2025 09:00 GMT, 75 min2 Jan 2025 10:45 GMT, 30 min2 Jan 2025 12:00 GMT, 30 min2 Jan 2025 12:45 GMT, 15 min5 Jan 2025 16:30 GMT, 57.3 h8 Jan 2025 02:15 GMT, 2 h8 Jan 2025 05:00 GMT, 15 min8 Jan 2025 05:30 GMT, 15 min8 Jan 2025 06:00 GMT, 90 min8 Jan 2025 07:45 GMT, 90 min8 Jan 2025 09:30 GMT, 2 h8 Jan 2025 11:45 GMT, 105 min8 Jan 2025 13:45 GMT, 30 min8 Jan 2025 14:30 GMT, 45 min8 Jan 2025 15:30 GMT, 2.8 h8 Jan 2025 18:30 GMT, 15 min8 Jan 2025 19:00 GMT, 15 min8 Jan 2025 20:30 GMT, 15 min8 Jan 2025 21:00 GMT, 45 min8 Jan 2025 22:00 GMT, 15 min8 Jan 2025 22:30 GMT, 15 min8 Jan 2025 23:00 GMT, 30 min8 Jan 2025 23:45 GMT, 15 min9 Jan 2025 00:30 GMT, 15 min9 Jan 2025 01:45 GMT, 15 min9 Jan 2025 03:00 GMT, 15 min9 Jan 2025 08:15 GMT, 15 min13 Jan 2025 23:00 GMT, 24 h14 Jan 2025 23:15 GMT, 105 min15 Jan 2025 01:45 GMT, 2 h15 Jan 2025 04:00 GMT, 75 min15 Jan 2025 05:30 GMT, 30 min15 Jan 2025 06:15 GMT, 2 h15 Jan 2025 08:30 GMT, 30 min15 Jan 2025 09:15 GMT, 45 min15 Jan 2025 10:15 GMT, 15 min15 Jan 2025 11:30 GMT, 15 min15 Jan 2025 12:15 GMT, 2.3 h15 Jan 2025 15:45 GMT, 15 min15 Jan 2025 16:15 GMT, 45 min15 Jan 2025 17:45 GMT, 45 min15 Jan 2025 18:45 GMT, 2 h15 Jan 2025 21:00 GMT, 15 min15 Jan 2025 21:30 GMT, 60 min15 Jan 2025 22:45 GMT, 15 min16 Jan 2025 07:45 GMT, 15 min16 Jan 2025 08:15 GMT, 30 min16 Jan 2025 09:00 GMT, 15 min16 Jan 2025 10:00 GMT, 15 min16 Jan 2025 10:30 GMT, 15 min24 Jan 2025 02:45 GMT, 6.8 h24 Jan 2025 10:00 GMT, 15 min24 Jan 2025 20:30 GMT, 30 min26 Jan 2025 16:30 GMT, 15 min26 Jan 2025 17:00 GMT, 45 min26 Jan 2025 18:15 GMT, 30 min27 Jan 2025 01:45 GMT, 22.5 h28 Jan 2025 00:30 GMT, 15 min28 Jan 2025 01:00 GMT, 75 min28 Jan 2025 02:30 GMT, 105 min28 Jan 2025 05:00 GMT, 30 min28 Jan 2025 06:00 GMT, 15 min28 Jan 2025 06:30 GMT, 8 h28 Jan 2025 14:45 GMT, 75 min28 Jan 2025 16:15 GMT, 2.3 h28 Jan 2025 18:45 GMT, 30 min28 Jan 2025 19:30 GMT, 105 min28 Jan 2025 21:45 GMT, 90 min28 Jan 2025 23:45 GMT, 45 min29 Jan 2025 08:00 GMT, 15 min20 Feb 2025 14:00 GMT, 30 min23 Feb 2025 20:45 GMT, 15 min22 Mar 2025 17:00 GMT, 75 min22 Mar 2025 23:30 GMT, 30 min7 Jul 2025 21:15 GMT, 45 min15 Jul 2025 17:30 GMT, 75 min15 Jul 2025 19:15 GMT, 30 min19 Jul 2025 12:15 GMT, 105 min19 Jul 2025 15:30 GMT, 15 min19 Jul 2025 16:00 GMT, 75 min20 Jul 2025 21:00 GMT, 75 min21 Jul 2025 15:15 GMT, 30 min23 Jul 2025 15:30 GMT, 15 min13 Sep 2025 21:00 GMT, 30 min20 Sep 2025 06:30 GMT, 30 min20 Sep 2025 09:15 GMT, 15 min20 Sep 2025 16:15 GMT, 10.5 h3 Oct 2025 14:00 GMT, 3.3 h6 Oct 2025 01:30 GMT, 15 min19 Oct 2025 18:30 GMT, 15 min19 Oct 2025 19:00 GMT, 15 min19 Oct 2025 22:15 GMT, 60 min19 Oct 2025 23:45 GMT, 90 min20 Oct 2025 14:45 GMT, 15 min1 Nov 2025 04:45 GMT, 15 min4 Nov 2025 20:30 GMT, 15 min4 Nov 2025 21:00 GMT, 15 min11 Nov 2025 20:45 GMT, 60 min12 Nov 2025 21:45 GMT, 45 min13 Nov 2025 02:00 GMT, 6.3 h13 Nov 2025 12:15 GMT, 15 min14 Nov 2025 01:45 GMT, 30 min14 Nov 2025 02:30 GMT, 2 h14 Nov 2025 04:45 GMT, 30 min14 Nov 2025 05:30 GMT, 105 min14 Nov 2025 07:30 GMT, 4.5 h14 Nov 2025 12:30 GMT, 105 min14 Nov 2025 15:15 GMT, 15 min14 Nov 2025 16:00 GMT, 30 min14 Nov 2025 16:45 GMT, 15 min14 Nov 2025 17:15 GMT, 15 min14 Nov 2025 21:15 GMT, 28 h16 Nov 2025 01:30 GMT, 15 min16 Nov 2025 02:15 GMT, 45 min16 Nov 2025 04:15 GMT, 15 min16 Nov 2025 09:45 GMT, 30 min19 Nov 2025 01:15 GMT, 30 min19 Nov 2025 02:45 GMT, 3.3 h19 Nov 2025 06:30 GMT, 15 min19 Nov 2025 07:30 GMT, 15 min19 Nov 2025 08:00 GMT, 4 h19 Nov 2025 12:15 GMT, 15 min19 Nov 2025 12:45 GMT, 90 min19 Nov 2025 18:15 GMT, 15 min23 Nov 2025 07:00 GMT, 15 min23 Nov 2025 13:30 GMT, 30 min23 Nov 2025 14:15 GMT, 2.3 h23 Nov 2025 17:15 GMT, 15 min24 Nov 2025 05:45 GMT, 30 min24 Nov 2025 07:30 GMT, 45 min24 Nov 2025 09:00 GMT, 15 min24 Nov 2025 09:30 GMT, 2.5 h24 Nov 2025 12:15 GMT, 15 min24 Nov 2025 12:45 GMT, 45 min24 Nov 2025 13:45 GMT, 105 min24 Nov 2025 15:45 GMT, 3.8 h24 Nov 2025 19:45 GMT, 30 min24 Nov 2025 21:30 GMT, 15 min28 Nov 2025 12:30 GMT, 75 min28 Nov 2025 14:30 GMT, 30 min29 Nov 2025 13:30 GMT, 45 min29 Nov 2025 14:30 GMT, 15 min29 Nov 2025 16:15 GMT, 11 h30 Nov 2025 03:30 GMT, 45 min30 Nov 2025 04:30 GMT, 3 h30 Nov 2025 07:45 GMT, 4.3 h30 Nov 2025 12:15 GMT, 75 min30 Nov 2025 13:45 GMT, 15 min30 Nov 2025 14:15 GMT, 15 min30 Nov 2025 15:15 GMT, 30 min30 Nov 2025 16:15 GMT, 15 min30 Nov 2025 19:45 GMT, 30 min30 Nov 2025 20:45 GMT, 15 min1 Dec 2025 05:00 GMT, 60 min1 Dec 2025 06:15 GMT, 15 min1 Dec 2025 06:45 GMT, 90 min1 Dec 2025 08:30 GMT, 45 min1 Dec 2025 09:30 GMT, 90 min1 Dec 2025 11:15 GMT, 30 min1 Dec 2025 12:45 GMT, 15 min1 Dec 2025 13:45 GMT, 15 min1 Dec 2025 14:45 GMT, 15 min1 Dec 2025 15:15 GMT, 15 min1 Dec 2025 15:45 GMT, 15 min1 Dec 2025 16:15 GMT, 15 min1 Dec 2025 18:45 GMT, 75 min1 Dec 2025 20:15 GMT, 90 min1 Dec 2025 22:00 GMT, 45 min1 Dec 2025 23:00 GMT, 45 min2 Dec 2025 00:00 GMT, 15 min2 Dec 2025 08:15 GMT, 15 min2 Dec 2025 08:45 GMT, 15 min5 Dec 2025 18:15 GMT, 31 h7 Dec 2025 01:30 GMT, 4.8 h7 Dec 2025 06:30 GMT, 6 h7 Dec 2025 13:00 GMT, 8 h7 Dec 2025 21:15 GMT, 8.3 h8 Dec 2025 05:45 GMT, 3.8 h8 Dec 2025 09:45 GMT, 6.3 h8 Dec 2025 16:15 GMT, 45 min8 Dec 2025 17:15 GMT, 30 min8 Dec 2025 18:00 GMT, 30 min8 Dec 2025 19:00 GMT, 75 min8 Dec 2025 21:00 GMT, 75 min8 Dec 2025 22:30 GMT, 75 min9 Dec 2025 00:00 GMT, 45 min9 Dec 2025 02:30 GMT, 15 min9 Dec 2025 03:00 GMT, 15 min9 Dec 2025 03:30 GMT, 68.5 h12 Dec 2025 00:15 GMT, 30 min12 Dec 2025 01:15 GMT, 15 min12 Dec 2025 02:00 GMT, 15 min12 Dec 2025 02:30 GMT, 15 min12 Dec 2025 03:00 GMT, 60 min12 Dec 2025 04:15 GMT, 30 min12 Dec 2025 05:30 GMT, 15 min12 Dec 2025 06:00 GMT, 45 min12 Dec 2025 07:00 GMT, 30 min12 Dec 2025 07:45 GMT, 45 min12 Dec 2025 08:45 GMT, 60 min12 Dec 2025 10:00 GMT, 45 min12 Dec 2025 11:15 GMT, 15 min12 Dec 2025 11:45 GMT, 60 min12 Dec 2025 13:30 GMT, 45 min12 Dec 2025 16:15 GMT, 15 min12 Dec 2025 17:30 GMT, 30 min12 Dec 2025 18:45 GMT, 15 min15 Dec 2025 10:15 GMT, 30 min15 Dec 2025 12:15 GMT, 30 min15 Dec 2025 13:00 GMT, 45 min15 Dec 2025 14:30 GMT, 30 min15 Dec 2025 15:30 GMT, 15 min15 Dec 2025 16:30 GMT, 15 min15 Dec 2025 17:00 GMT, 15 min15 Dec 2025 17:30 GMT, 15 min15 Dec 2025 18:15 GMT, 15 min15 Dec 2025 22:15 GMT, 15 min18 Dec 2025 15:15 GMT, 75 min22 Dec 2025 01:00 GMT, 15 min

Hours spilling by month, 2025

0100200300Jan 2025: 201 hours spillingJanFeb 2025: 0.8 hours spillingFebMar 2025: 1.8 hours spillingMarApr 2025: 0.0 hours spillingAprMay 2025: 0.0 hours spillingMayJun 2025: 0.0 hours spillingJunJul 2025: 7.8 hours spillingJulAug 2025: 0.0 hours spillingAugSep 2025: 12 hours spillingSepOct 2025: 6.8 hours spillingOctNov 2025: 101 hours spillingNovDec 2025: 170 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
9 Dec 2025, 03:30Hunton STW Final Effluent2.9 days
5 Jan 2025, 16:30Hunton STW Final Effluent2.4 days
5 Dec 2025, 18:15Hunton STW Final Effluent1.3 days
14 Nov 2025, 21:15Hunton STW Final Effluent1.2 days
1 Jan 2025, 00:00Hunton STW Final Effluent1.1 days

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate8,581 m³range 3,418 – 21,543 m³
In litres8.6 millionrange 3.4 million – 21.5 million L
Olympic swimming pools3.4at 2,500 m³ each
Organic load, as people's raw sewage12,871person-days of untreated BOD

Assumed spill rate while spilling: 1.9 – 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 137 kg772 kg4,309 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 359 kg3,647 kg15,532 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 6.5 kg54 kg200 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3–9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 4.1 kg22 kg116 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 341.8 billion organisms8.6 trillion organisms215.4 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Hunton STW Final Effluent

Inlet overflow at sewage works · discharges to Hunton Beck

Spills 2025
63 (501 hours) · down 14% on 2024
Spills 2024
73 (692 hours)
Long-term average
61.8 spills a year (monitored since 2020)
Monitor uptime
100% of the year
High-spill reason (company)
Not asset maintenance - hydraulic capacity
Investigation
Env Act (SODRP) investigation completed, UWWTR investigation completed, Operational investigation completed
Improvement
No improvement action in reporting period
WFD catchment
Brompton Bk from Source to Newton Bk (GB104027068960)
Outlet location
SE1947092120 (OS grid reference) · View on Apple Maps
EA ID / permit
YWS00370 · 27/23/0275 · company name: HUNTON/STW

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024–25 [EA]. Infiltration of groundwater into sewers is taken as 0–40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies – environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 – per capita consumption
  3. HBF: Foul sewer design – historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 – CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Yorkshire Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.