Storm overflow register · Yorkshire Water

Malton sewage works: storm overflow spills 2025

Malton sewage treatment works, run by Yorkshire Water, has 1 monitored storm overflow discharging to The River Derwent. In 2025 it recorded 35 spills totalling 419 hours, against 25 spills and 221 hours in 2024. By hours spilling, it ranks 107 of 283 Yorkshire Water works, where 1 spilled longest.

Works size: 33,085 population equivalent (MALTON STW, UWWTD 2018). Used for the spill volume estimate.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecMalton Sewage…1 Jan 2025 05:45 GMT, 4 h5 Jan 2025 16:00 GMT, 11.5 h6 Jan 2025 05:00 GMT, 5.5 h6 Jan 2025 10:45 GMT, 45 min6 Jan 2025 11:45 GMT, 2.8 h6 Jan 2025 15:15 GMT, 15 min8 Jan 2025 03:15 GMT, 15 min8 Jan 2025 03:30 GMT, 15 min8 Jan 2025 04:15 GMT, 15 min8 Jan 2025 08:00 GMT, 15 min8 Jan 2025 08:15 GMT, 60 min8 Jan 2025 09:15 GMT, 45 min8 Jan 2025 10:15 GMT, 30 min8 Jan 2025 10:45 GMT, 30 min8 Jan 2025 12:15 GMT, 15 min8 Jan 2025 12:30 GMT, 30 min8 Jan 2025 13:00 GMT, 45 min8 Jan 2025 13:45 GMT, 15 min8 Jan 2025 14:30 GMT, 12.5 h9 Jan 2025 03:00 GMT, 15 min9 Jan 2025 08:45 GMT, 4 h9 Jan 2025 13:00 GMT, 45 min9 Jan 2025 13:45 GMT, 15 min9 Jan 2025 14:00 GMT, 30 min9 Jan 2025 14:30 GMT, 15 min9 Jan 2025 15:00 GMT, 45 min9 Jan 2025 16:00 GMT, 30 min9 Jan 2025 17:45 GMT, 30 min9 Jan 2025 19:15 GMT, 15 min9 Jan 2025 19:45 GMT, 15 min9 Jan 2025 20:45 GMT, 15 min9 Jan 2025 21:00 GMT, 15 min9 Jan 2025 21:15 GMT, 15 min9 Jan 2025 23:15 GMT, 15 min10 Jan 2025 08:30 GMT, 15 min10 Jan 2025 09:00 GMT, 15 min10 Jan 2025 10:15 GMT, 15 min10 Jan 2025 10:45 GMT, 15 min27 Jan 2025 05:00 GMT, 3 h27 Jan 2025 08:00 GMT, 2 h27 Jan 2025 10:00 GMT, 15 min27 Jan 2025 10:30 GMT, 30 min27 Jan 2025 19:30 GMT, 15 min27 Jan 2025 19:45 GMT, 15 min27 Jan 2025 23:45 GMT, 15 min28 Jan 2025 00:00 GMT, 2.5 h28 Jan 2025 04:15 GMT, 15 min28 Jan 2025 04:45 GMT, 15 min28 Jan 2025 06:15 GMT, 15 min28 Jan 2025 06:45 GMT, 15 min28 Jan 2025 07:45 GMT, 15 min28 Jan 2025 08:15 GMT, 15 min28 Jan 2025 08:30 GMT, 2.3 h28 Jan 2025 10:45 GMT, 15 min28 Jan 2025 11:00 GMT, 15 min28 Jan 2025 12:00 GMT, 15 min28 Jan 2025 12:45 GMT, 15 min28 Jan 2025 14:00 GMT, 15 min28 Jan 2025 15:45 GMT, 15 min28 Jan 2025 16:00 GMT, 15 min28 Jan 2025 17:00 GMT, 15 min28 Jan 2025 17:15 GMT, 15 min28 Jan 2025 19:15 GMT, 15 min28 Jan 2025 19:30 GMT, 15 min28 Jan 2025 20:00 GMT, 15 min28 Jan 2025 22:30 GMT, 30 min28 Jan 2025 23:00 GMT, 15 min15 Jul 2025 23:45 GMT, 105 min15 Sep 2025 13:15 GMT, 3.3 h20 Sep 2025 17:00 GMT, 8 h21 Sep 2025 01:45 GMT, 15 min14 Nov 2025 23:15 GMT, 105 min15 Nov 2025 01:00 GMT, 15 min15 Nov 2025 01:15 GMT, 15 min15 Nov 2025 01:45 GMT, 75 min29 Nov 2025 19:30 GMT, 4.8 h30 Nov 2025 00:15 GMT, 15 min1 Dec 2025 08:30 GMT, 9.5 h1 Dec 2025 18:15 GMT, 30 min1 Dec 2025 18:45 GMT, 30 min1 Dec 2025 19:15 GMT, 15 min1 Dec 2025 19:30 GMT, 15 min1 Dec 2025 19:45 GMT, 90 min1 Dec 2025 21:15 GMT, 3 h2 Dec 2025 00:15 GMT, 15 min2 Dec 2025 00:30 GMT, 30 min2 Dec 2025 01:00 GMT, 45 min2 Dec 2025 01:45 GMT, 30 min2 Dec 2025 02:15 GMT, 15 min2 Dec 2025 02:30 GMT, 15 min2 Dec 2025 04:15 GMT, 15 min2 Dec 2025 04:45 GMT, 30 min2 Dec 2025 05:15 GMT, 15 min2 Dec 2025 05:30 GMT, 30 min2 Dec 2025 06:00 GMT, 15 min2 Dec 2025 06:15 GMT, 15 min2 Dec 2025 06:45 GMT, 15 min2 Dec 2025 07:00 GMT, 30 min2 Dec 2025 07:45 GMT, 2 h2 Dec 2025 09:45 GMT, 45 min2 Dec 2025 10:30 GMT, 45 min2 Dec 2025 11:30 GMT, 90 min2 Dec 2025 13:00 GMT, 90 min2 Dec 2025 14:30 GMT, 15 min2 Dec 2025 14:45 GMT, 15 min2 Dec 2025 15:00 GMT, 15 min2 Dec 2025 15:15 GMT, 75 min2 Dec 2025 16:30 GMT, 15 min2 Dec 2025 16:45 GMT, 15 min2 Dec 2025 17:00 GMT, 15 min2 Dec 2025 17:15 GMT, 15 min2 Dec 2025 17:30 GMT, 15 min2 Dec 2025 17:45 GMT, 45 min2 Dec 2025 18:30 GMT, 15 min2 Dec 2025 18:45 GMT, 90 min2 Dec 2025 20:15 GMT, 30 min2 Dec 2025 20:45 GMT, 15 min2 Dec 2025 21:00 GMT, 15 min2 Dec 2025 21:15 GMT, 45 min2 Dec 2025 22:00 GMT, 30 min2 Dec 2025 22:45 GMT, 15 min2 Dec 2025 23:15 GMT, 60 min3 Dec 2025 00:30 GMT, 15 min3 Dec 2025 00:45 GMT, 45 min3 Dec 2025 01:30 GMT, 15 min3 Dec 2025 08:45 GMT, 3.3 h3 Dec 2025 12:00 GMT, 15 min3 Dec 2025 12:30 GMT, 30 min3 Dec 2025 13:00 GMT, 30 min3 Dec 2025 13:30 GMT, 30 min3 Dec 2025 14:00 GMT, 3 h3 Dec 2025 17:00 GMT, 8 h4 Dec 2025 01:45 GMT, 15 min4 Dec 2025 04:45 GMT, 15 min4 Dec 2025 06:15 GMT, 15 min4 Dec 2025 06:30 GMT, 30 min4 Dec 2025 07:00 GMT, 15 min4 Dec 2025 07:15 GMT, 5.5 h4 Dec 2025 12:45 GMT, 2.3 h4 Dec 2025 15:00 GMT, 15 min4 Dec 2025 15:15 GMT, 15 min4 Dec 2025 15:30 GMT, 30 min4 Dec 2025 16:15 GMT, 15 min4 Dec 2025 16:30 GMT, 15 min4 Dec 2025 16:45 GMT, 45 min4 Dec 2025 17:30 GMT, 7.3 h5 Dec 2025 00:45 GMT, 30 min5 Dec 2025 02:30 GMT, 90 min5 Dec 2025 19:45 GMT, 5.3 h7 Dec 2025 22:30 GMT, 15 min7 Dec 2025 23:00 GMT, 45 min8 Dec 2025 10:45 GMT, 2.8 h8 Dec 2025 13:30 GMT, 15 min8 Dec 2025 14:00 GMT, 45 min8 Dec 2025 14:45 GMT, 15 min8 Dec 2025 15:00 GMT, 15 min8 Dec 2025 15:15 GMT, 2.8 h8 Dec 2025 18:00 GMT, 3 h8 Dec 2025 21:00 GMT, 75 min8 Dec 2025 22:15 GMT, 75 min8 Dec 2025 23:30 GMT, 45 min9 Dec 2025 00:15 GMT, 15 min9 Dec 2025 00:45 GMT, 30 min9 Dec 2025 01:45 GMT, 30 min9 Dec 2025 04:45 GMT, 21.3 h10 Dec 2025 09:15 GMT, 15 h11 Dec 2025 00:15 GMT, 30 min11 Dec 2025 00:45 GMT, 30 min11 Dec 2025 01:15 GMT, 15 min11 Dec 2025 09:30 GMT, 2.5 h11 Dec 2025 12:15 GMT, 2.5 h11 Dec 2025 14:45 GMT, 45 min11 Dec 2025 15:30 GMT, 30 min11 Dec 2025 16:15 GMT, 60 min11 Dec 2025 17:30 GMT, 15 min11 Dec 2025 17:45 GMT, 2 h11 Dec 2025 19:45 GMT, 2.5 h11 Dec 2025 22:15 GMT, 30 min11 Dec 2025 22:45 GMT, 30 min11 Dec 2025 23:15 GMT, 45 min12 Dec 2025 00:00 GMT, 15 min12 Dec 2025 00:45 GMT, 15 min12 Dec 2025 01:15 GMT, 15 min12 Dec 2025 03:00 GMT, 15 min12 Dec 2025 10:15 GMT, 15 min12 Dec 2025 10:45 GMT, 15 min12 Dec 2025 11:00 GMT, 15 min12 Dec 2025 11:15 GMT, 2.3 h12 Dec 2025 13:30 GMT, 9 h12 Dec 2025 22:30 GMT, 60 min12 Dec 2025 23:30 GMT, 3.3 h15 Dec 2025 07:30 GMT, 16 h16 Dec 2025 00:00 GMT, 15 min16 Dec 2025 00:45 GMT, 15 min16 Dec 2025 01:15 GMT, 15 min16 Dec 2025 02:00 GMT, 15 min16 Dec 2025 15:15 GMT, 30 min16 Dec 2025 16:15 GMT, 60 min16 Dec 2025 17:15 GMT, 15 min16 Dec 2025 17:30 GMT, 4.3 h16 Dec 2025 22:00 GMT, 3.3 h17 Dec 2025 01:15 GMT, 45 min17 Dec 2025 02:00 GMT, 105 min17 Dec 2025 03:45 GMT, 135.3 h

Estimated spill volume by month, 2025

Hours spilling each month × the estimated spill rate for a works of this size. The bars are central estimates and the whiskers show the low–high range. Method.

0200k400k600kJan 2025: 70 h spilling ≈ 39,399 m³ (range 15,693–98,913 m³)JanFeb 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)FebMar 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)MarApr 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)AprMay 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)MayJun 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)JunJul 2025: 1.8 h spilling ≈ 1,020 m³ (range 406–2,562 m³)JulAug 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)AugSep 2025: 12 h spilling ≈ 6,519 m³ (range 2,597–16,367 m³)SepOct 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)OctNov 2025: 8.5 h spilling ≈ 4,819 m³ (range 1,919–12,097 m³)NovDec 2025: 328 h spilling ≈ 185,827 m³ (range 74,019–466,527 m³)Dec
Cubic metres (m³), estimate. Hours are measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDurationEstimated volume
17 Dec 2025, 03:45Malton Sewage Treatment Works5.6 days30,540 – 192,489 m³
9 Dec 2025, 04:45Malton Sewage Treatment Works21.3 h4,798 – 30,243 m³
15 Dec 2025, 07:30Malton Sewage Treatment Works16.0 h3,613 – 22,771 m³
10 Dec 2025, 09:15Malton Sewage Treatment Works15.0 h3,387 – 21,348 m³
8 Jan 2025, 14:30Malton Sewage Treatment Works12.5 h2,823 – 17,790 m³

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

Volume, central estimate237,528 m³range 94,612 – 596,323 m³
In litres237.5 millionrange 94.6 million – 596.3 million L
Olympic swimming pools95at 2,500 m³ each
Organic load, as people's raw sewage356,292person-days of untreated BOD

Assumed spill rate while spilling: 62.7 – 395.3 L/s (central 157.5 L/s), from a dry-weather flow of 62.7 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 3,784 kg21,378 kg119,265 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 9,934 kg100,949 kg429,949 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 180 kg1,496 kg5,546 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3–9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 114 kg618 kg3,220 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 9.5 trillion organisms237.5 trillion organisms6.0 × 10¹⁵ organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Malton Sewage Treatment Works

Storm tank at sewage works · discharges to The River Derwent

Spills 2025
35 (419 hours) · up 40% on 2024
Spills 2024
25 (221 hours)
Long-term average
32.8 spills a year (monitored since 2020)
Monitor uptime
100% of the year
High-spill reason (company)
Performance - SW Infiltration
Investigation
UWWTR investigation ongoing, Operational investigation completed
Improvement
No improvement action in reporting period
WFD catchment
Derwent from River Rye to Kirkham (GB104027068313)
Outlet location
SE7757070410 (OS grid reference) · View on Apple Maps
EA ID / permit
YWS00509 · QR.27/27/0040 · company name: MALTON/STW/3XDWF OVERFLOW

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024–25 [EA]. Infiltration of groundwater into sewers is taken as 0–40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies – environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 – per capita consumption
  3. HBF: Foul sewer design – historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 – CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Yorkshire Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.