Storm overflow register · Yorkshire Water

Marske sewage works: storm overflow spills 2025

Marske sewage treatment works, run by Yorkshire Water, has 1 monitored storm overflow discharging to Marske Beck. In 2025 it recorded 170 spills totalling 2,046 hours, against 136 spills and 1,326 hours in 2024. By hours spilling, it ranks 4 of 283 Yorkshire Water works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecMarske Sewage…57 spills, 173 h, 1 Jan to 9 Jan45 spills, 116.8 h, 12 Jan to 19 Jan20 Jan 2025 23:15 GMT, 15 min72 spills, 172 h, 23 Jan to 2 Feb7 spills, 5 h, 4 Feb to 4 Feb4 spills, 1 h, 5 Feb to 6 Feb4 spills, 6.8 h, 8 Feb to 9 Feb16 spills, 14.8 h, 10 Feb to 13 Feb14 Feb 2025 21:45 GMT, 75 min4 spills, 21 h, 15 Feb to 16 Feb18 Feb 2025 16:45 GMT, 30 min191 spills, 354 h, 19 Feb to 12 Mar13 Mar 2025 15:45 GMT, 15 min3 spills, 11.3 h, 22 Mar to 23 Mar23 May 2025 23:45 GMT, 45 min26 May 2025 22:15 GMT, 30 min29 May 2025 04:45 GMT, 2.3 h6 Jun 2025 06:30 GMT, 2.5 h7 Jun 2025 12:00 GMT, 15 min21 Jun 2025 19:45 GMT, 30 min2 Jul 2025 02:00 GMT, 30 min2 spills, 1 h, 6 Jul to 6 Jul5 spills, 6.5 h, 15 Jul to 15 Jul3 spills, 3 h, 19 Jul to 19 Jul2 spills, 1.5 h, 20 Jul to 21 Jul4 Aug 2025 07:15 GMT, 15 min27 Aug 2025 14:15 GMT, 15 min28 Aug 2025 15:15 GMT, 15 min30 Aug 2025 20:15 GMT, 30 min31 Aug 2025 16:00 GMT, 15 min1 Sep 2025 12:15 GMT, 45 min4 spills, 2.3 h, 3 Sep to 3 Sep7 Sep 2025 14:15 GMT, 45 min10 spills, 19 h, 10 Sep to 12 Sep13 Sep 2025 21:45 GMT, 105 min6 spills, 17.3 h, 14 Sep to 16 Sep2 spills, 7 h, 17 Sep to 17 Sep2 spills, 29.3 h, 20 Sep to 21 Sep2 spills, 6.5 h, 27 Sep to 28 Sep1 Oct 2025 04:45 GMT, 9.8 h8 spills, 42.8 h, 2 Oct to 6 Oct11 spills, 19.8 h, 19 Oct to 20 Oct3 spills, 1.8 h, 24 Oct to 24 Oct28 Oct 2025 00:15 GMT, 60 min29 Oct 2025 02:15 GMT, 15 min31 Oct 2025 01:45 GMT, 15 min4 spills, 5.3 h, 1 Nov to 2 Nov100 spills, 428.3 h, 3 Nov to 26 Nov7 spills, 101.8 h, 27 Nov to 2 Dec77 spills, 367.8 h, 3 Dec to 24 Dec33 spills, 83.5 h, 25 Dec to 29 Dec2 spills, 0.5 h, 30 Dec to 30 Dec31 Dec 2025 21:45 GMT, 15 min

Hours spilling by month, 2025

0200400600Jan 2025: 451 hours spillingJanFeb 2025: 268 hours spillingFebMar 2025: 159 hours spillingMarApr 2025: 0.0 hours spillingAprMay 2025: 3.5 hours spillingMayJun 2025: 3.2 hours spillingJunJul 2025: 13 hours spillingJulAug 2025: 1.5 hours spillingAugSep 2025: 85 hours spillingSepOct 2025: 76 hours spillingOctNov 2025: 496 hours spillingNovDec 2025: 492 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
11 Nov 2025, 18:45Marske Sewage Treatment Works9.1 days
15 Dec 2025, 07:45Marske Sewage Treatment Works6.2 days
23 Feb 2025, 07:15Marske Sewage Treatment Works4.2 days
28 Nov 2025, 10:30Marske Sewage Treatment Works4.1 days
26 Jan 2025, 14:30Marske Sewage Treatment Works4.1 days

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate35,054 m³range 13,963 - 88,003 m³
In litres35.1 millionrange 14.0 million - 88.0 million L
Olympic swimming pools14at 2,500 m³ each
Organic load, as people's raw sewage52,580person-days of untreated BOD

Assumed spill rate while spilling: 1.9 - 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 559 kg3,155 kg17,601 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 1,466 kg14,898 kg63,451 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 27 kg221 kg818 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3-9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 17 kg91 kg475 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 1.4 trillion organisms35.1 trillion organisms880.0 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Marske Sewage Treatment Works

Inlet overflow at sewage works · discharges to Marske Beck

Spills 2025
170 (2,046 hours) · up 25% on 2024
Spills 2024
136 (1,326 hours)
Long-term average
152.7 spills a year (monitored since 2020)
Monitor uptime
100% of the year
High-spill reason (company)
Not asset maintenance - hydraulic capacity
Investigation
UWWTR investigation ongoing, Operational investigation completed
Improvement
No improvement action in reporting period
WFD catchment
Marske Beck from Source to River Swale (GB104027069140)
Outlet location
NZ1041000430 (OS grid reference) · View on Apple Maps
EA ID / permit
YWS00349 · 27/23/0208 · company name: MARSKE/STW

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024-25 [EA]. Infiltration of groundwater into sewers is taken as 0-40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies - environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 - per capita consumption
  3. HBF: Foul sewer design - historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 - CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Yorkshire Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.