Storm overflow register · Yorkshire Water

Mitchell Laithes sewage works: storm overflow spills 2025

Mitchell Laithes sewage treatment works, run by Yorkshire Water, has 2 monitored storm overflows discharging to River Calder. In 2025 they recorded 61 spills totalling 523 hours, against 75 spills and 505 hours in 2024. By hours spilling, it ranks 86 of 283 Yorkshire Water works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecMitchell Laithes WwTW22 spills, 39.8 h, 1 Jan to 2 Jan55 spills, 59 h, 5 Jan to 9 Jan4 spills, 1 h, 6 Jul to 6 Jul8 spills, 9 h, 20 Jul to 21 Jul2 spills, 3.5 h, 17 Sep to 17 Sep20 Sep 2025 14:15 GMT, 23.3 h28 Sep 2025 04:00 GMT, 18.8 h22 spills, 14.5 h, 3 Oct to 4 Oct3 spills, 2.8 h, 20 Oct to 20 Oct9 spills, 8.8 h, 11 Nov to 12 Nov33 spills, 54 h, 14 Nov to 16 Nov9 spills, 6.8 h, 18 Nov to 19 Nov10 spills, 6.5 h, 23 Nov to 23 Nov9 spills, 8.5 h, 29 Nov to 30 Nov41 spills, 31.8 h, 5 Dec to 8 Dec15 spills, 22 h, 9 Dec to 10 Dec19 spills, 27.8 h, 15 Dec to 16 Dec44 spills, 46.8 h, 17 Dec to 20 Dec45 spills, 29.3 h, 21 Dec to 23 DecMitchell Laithes WwTW1 Jan 2025 01:00 GMT, 24.5 h5 Jan 2025 19:15 GMT, 21.3 h22 Mar 2025 17:15 GMT, 13 h6 Jul 2025 18:00 GMT, 105 min21 Jul 2025 18:00 GMT, 2.5 h3 spills, 12.8 h, 20 Sep to 21 Sep28 Sep 2025 01:30 GMT, 2 h19 Oct 2025 23:00 GMT, 60 min11 Nov 2025 21:45 GMT, 90 min2 spills, 21.8 h, 14 Nov to 15 Nov28 Nov 2025 13:30 GMT, 3.8 h29 Nov 2025 14:45 GMT, 60 min2 spills, 1.8 h, 9 Dec to 9 Dec2 spills, 1.3 h, 18 Dec to 18 Dec

Hours spilling by month, 2025

050100150200Jan 2025: 145 hours spillingJanFeb 2025: 0.0 hours spillingFebMar 2025: 13 hours spillingMarApr 2025: 0.0 hours spillingAprMay 2025: 0.0 hours spillingMayJun 2025: 0.0 hours spillingJunJul 2025: 14 hours spillingJulAug 2025: 0.0 hours spillingAugSep 2025: 60 hours spillingSepOct 2025: 18 hours spillingOctNov 2025: 113 hours spillingNovDec 2025: 161 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
14 Nov 2025, 12:00Mitchell Laithes WwTW1.6 days
5 Jan 2025, 17:15Mitchell Laithes WwTW1.5 days
1 Jan 2025, 01:00Mitchell Laithes WwTW1.0 days
20 Sep 2025, 14:15Mitchell Laithes WwTW23.3 h
5 Jan 2025, 19:15Mitchell Laithes WwTW21.3 h

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate8,965 m³range 3,571 - 22,506 m³
In litres9.0 millionrange 3.6 million - 22.5 million L
Olympic swimming pools3.6at 2,500 m³ each
Organic load, as people's raw sewage13,447person-days of untreated BOD

Assumed spill rate while spilling: 1.9 - 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 143 kg807 kg4,501 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 375 kg3,810 kg16,227 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 6.8 kg56 kg209 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3-9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 4.3 kg23 kg122 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 357.1 billion organisms9.0 trillion organisms225.1 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Mitchell Laithes WwTW

Storm tank at sewage works · discharges to River Calder

Spills 2025
42 (414 hours) · down 33% on 2024
Spills 2024
63 (440 hours)
Long-term average
57.2 spills a year (monitored since 2020)
Monitor uptime
100% of the year
High-spill reason (company)
Not asset maintenance - hydraulic capacity
Investigation
UWWTR investigation ongoing, Operational investigation completed
Improvement
No improvement action in reporting period
WFD catchment
Calder from River Colne to River Chald (GB104027062631)
Outlet location
SE2646019490 (OS grid reference) · View on Apple Maps
EA ID / permit
YWS00889 · E15 · company name: DEWSBURY/STW/3XDWF OVERFLOW

Mitchell Laithes WwTW

Inlet overflow at sewage works · discharges to River Calder

Spills 2025
19 (110 hours) · up 58% on 2024
Spills 2024
12 (65 hours)
Long-term average
27.8 spills a year (monitored since 2020)
Monitor uptime
100% of the year
Investigation
UWWTR investigation ongoing, Operational investigation completed
Improvement
No improvement action in reporting period
WFD catchment
Calder from River Colne to River Chald (GB104027062631)
Outlet location
SE2646019490 (OS grid reference) · View on Apple Maps
EA ID / permit
YWS00890 · E15 · company name: DEWSBURY/STW/6XDWF OVERFLOW

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024-25 [EA]. Infiltration of groundwater into sewers is taken as 0-40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies - environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 - per capita consumption
  3. HBF: Foul sewer design - historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 - CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Yorkshire Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.