Storm overflow register · Yorkshire Water

Wrangbrook sewage works: storm overflow spills 2025

Wrangbrook sewage treatment works, run by Yorkshire Water, has 1 monitored storm overflow discharging to The Skell (Wrangbrook Dyke). In 2025 it recorded 27 spills totalling 288 hours, against 31 spills and 331 hours in 2024. By hours spilling, it ranks 142 of 283 Yorkshire Water works, where 1 spilled longest.

Works size: 6,340 population equivalent (WRANGBROOK STW, UWWTD 2018). Used for the spill volume estimate.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecWrangbrook STW1 Jan 2025 01:52 GMT, 22.2 h2 Jan 2025 00:08 GMT, 4 min2 Jan 2025 00:16 GMT, 60 min2 Jan 2025 01:18 GMT, 8 min2 Jan 2025 01:34 GMT, 10 min2 Jan 2025 01:46 GMT, 2 min2 Jan 2025 01:50 GMT, 12 min2 Jan 2025 02:04 GMT, 2 min2 Jan 2025 02:10 GMT, 4 min2 Jan 2025 02:20 GMT, 2 min2 Jan 2025 02:24 GMT, 2 min2 Jan 2025 02:30 GMT, 2 min5 Jan 2025 18:08 GMT, 26.1 h6 Jan 2025 20:22 GMT, 17 h7 Jan 2025 13:20 GMT, 4 min7 Jan 2025 13:26 GMT, 11.2 h8 Jan 2025 00:40 GMT, 4 min8 Jan 2025 00:46 GMT, 2 min8 Jan 2025 00:50 GMT, 8 min8 Jan 2025 01:00 GMT, 6 min8 Jan 2025 01:08 GMT, 2 min8 Jan 2025 01:12 GMT, 6 min8 Jan 2025 01:20 GMT, 6 min8 Jan 2025 01:28 GMT, 2 min8 Jan 2025 01:32 GMT, 2 min8 Jan 2025 01:42 GMT, 2 min8 Jan 2025 01:48 GMT, 2 min8 Jan 2025 01:52 GMT, 4 min8 Jan 2025 02:00 GMT, 90 min8 Jan 2025 03:32 GMT, 4 min8 Jan 2025 03:38 GMT, 14 min8 Jan 2025 03:56 GMT, 10 min8 Jan 2025 04:08 GMT, 8 min8 Jan 2025 04:18 GMT, 4 min8 Jan 2025 04:24 GMT, 2 min8 Jan 2025 06:30 GMT, 2.5 h8 Jan 2025 09:04 GMT, 6 min8 Jan 2025 09:14 GMT, 12 min8 Jan 2025 09:28 GMT, 2 min8 Jan 2025 09:32 GMT, 2 min8 Jan 2025 09:36 GMT, 6 min8 Jan 2025 09:44 GMT, 10 min8 Jan 2025 09:56 GMT, 4 min8 Jan 2025 10:02 GMT, 8 min8 Jan 2025 10:12 GMT, 2 min8 Jan 2025 10:16 GMT, 2 min8 Jan 2025 10:20 GMT, 8 min8 Jan 2025 10:42 GMT, 4 min8 Jan 2025 20:30 GMT, 4 min8 Jan 2025 20:36 GMT, 2 min8 Jan 2025 20:42 GMT, 62 min8 Jan 2025 21:48 GMT, 10 min8 Jan 2025 22:02 GMT, 10 min8 Jan 2025 22:14 GMT, 14 min8 Jan 2025 22:30 GMT, 14 min8 Jan 2025 22:48 GMT, 2 min8 Jan 2025 22:52 GMT, 2 min9 Jan 2025 19:18 GMT, 2 min27 Jan 2025 03:54 GMT, 8.4 h27 Jan 2025 12:20 GMT, 2 min27 Jan 2025 12:26 GMT, 2 min27 Jan 2025 12:52 GMT, 6 min27 Jan 2025 13:14 GMT, 28 min27 Jan 2025 13:44 GMT, 30 min27 Jan 2025 14:16 GMT, 10 min27 Jan 2025 14:28 GMT, 4 min27 Jan 2025 14:34 GMT, 2 min27 Jan 2025 14:44 GMT, 10 min27 Jan 2025 14:58 GMT, 6 min27 Jan 2025 16:46 GMT, 2 min27 Jan 2025 17:02 GMT, 4 min27 Jan 2025 17:14 GMT, 2 min27 Jan 2025 17:28 GMT, 2 min27 Jan 2025 17:30 GMT, 2 min27 Jan 2025 17:36 GMT, 2 min27 Jan 2025 17:38 GMT, 2 min27 Jan 2025 18:04 GMT, 2 min27 Jan 2025 18:06 GMT, 2 min27 Jan 2025 21:08 GMT, 2 min27 Jan 2025 21:16 GMT, 2 min27 Jan 2025 21:22 GMT, 2 min27 Jan 2025 22:34 GMT, 2 min27 Jan 2025 22:36 GMT, 2 min27 Jan 2025 22:40 GMT, 2 min27 Jan 2025 22:42 GMT, 2.2 h28 Jan 2025 00:58 GMT, 2 min28 Jan 2025 01:02 GMT, 2 min20 Sep 2025 16:50 GMT, 12.2 h21 Sep 2025 05:04 GMT, 12 min21 Sep 2025 05:18 GMT, 14 min21 Sep 2025 05:34 GMT, 2 min4 Nov 2025 17:52 GMT, 44 min4 Nov 2025 19:38 GMT, 2.2 h14 Nov 2025 11:00 GMT, 38 h16 Nov 2025 01:00 GMT, 4 min29 Nov 2025 09:58 GMT, 31.8 h30 Nov 2025 18:10 GMT, 2 min30 Nov 2025 19:06 GMT, 2 min4 Dec 2025 22:08 GMT, 4.9 h5 Dec 2025 03:02 GMT, 98 min5 Dec 2025 04:42 GMT, 4 min5 Dec 2025 04:48 GMT, 4 min5 Dec 2025 04:52 GMT, 2 min5 Dec 2025 08:50 GMT, 2 min5 Dec 2025 19:08 GMT, 9.6 h6 Dec 2025 04:42 GMT, 4 min6 Dec 2025 11:54 GMT, 5.4 h9 Dec 2025 10:26 GMT, 15.6 h10 Dec 2025 02:06 GMT, 4 min10 Dec 2025 02:12 GMT, 2 min10 Dec 2025 02:14 GMT, 2 min10 Dec 2025 02:16 GMT, 2 min10 Dec 2025 02:20 GMT, 2 min10 Dec 2025 02:24 GMT, 2 min10 Dec 2025 02:28 GMT, 2 min10 Dec 2025 02:36 GMT, 2 min15 Dec 2025 18:02 GMT, 11.3 h16 Dec 2025 05:28 GMT, 2 min16 Dec 2025 05:30 GMT, 4 min16 Dec 2025 05:38 GMT, 2 min16 Dec 2025 09:20 GMT, 2 min16 Dec 2025 09:26 GMT, 2 min16 Dec 2025 09:32 GMT, 6.2 h16 Dec 2025 15:46 GMT, 7.2 h16 Dec 2025 23:04 GMT, 2 min16 Dec 2025 23:12 GMT, 8 min16 Dec 2025 23:22 GMT, 4 min16 Dec 2025 23:28 GMT, 16 min17 Dec 2025 22:24 GMT, 5.9 h18 Dec 2025 04:16 GMT, 2 min18 Dec 2025 10:42 GMT, 2 min18 Dec 2025 12:12 GMT, 2 min18 Dec 2025 13:42 GMT, 28.4 h19 Dec 2025 18:26 GMT, 4.7 h19 Dec 2025 23:10 GMT, 2 min19 Dec 2025 23:14 GMT, 32 min

Estimated spill volume by month, 2025

Hours spilling each month × the estimated spill rate for a works of this size. The bars are central estimates and the whiskers show the low–high range. Method.

010k20k30kJan 2025: 100 h spilling ≈ 10,842 m³ (range 4,318–27,218 m³)JanFeb 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)FebMar 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)MarApr 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)AprMay 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)MayJun 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)JunJul 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)JulAug 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)AugSep 2025: 13 h spilling ≈ 1,380 m³ (range 550–3,464 m³)SepOct 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)OctNov 2025: 73 h spilling ≈ 7,908 m³ (range 3,150–19,854 m³)NovDec 2025: 103 h spilling ≈ 11,146 m³ (range 4,440–27,982 m³)Dec
Cubic metres (m³), estimate. Hours are measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDurationEstimated volume
14 Nov 2025, 11:00Wrangbrook STW1.6 days1,643 – 10,354 m³
29 Nov 2025, 09:58Wrangbrook STW1.3 days1,376 – 8,673 m³
18 Dec 2025, 13:42Wrangbrook STW1.2 days1,230 – 7,754 m³
5 Jan 2025, 18:08Wrangbrook STW1.1 days1,129 – 7,118 m³
1 Jan 2025, 01:52Wrangbrook STW22.2 h961 – 6,055 m³

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

Volume, central estimate31,286 m³range 12,462 – 78,545 m³
In litres31.3 millionrange 12.5 million – 78.5 million L
Olympic swimming pools13at 2,500 m³ each
Organic load, as people's raw sewage46,929person-days of untreated BOD

Assumed spill rate while spilling: 12.0 – 75.8 L/s (central 30.2 L/s), from a dry-weather flow of 12.0 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 498 kg2,816 kg15,709 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 1,308 kg13,297 kg56,631 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 24 kg197 kg730 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3–9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 15 kg81 kg424 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 1.2 trillion organisms31.3 trillion organisms785.4 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Wrangbrook STW

Storm tank at sewage works · discharges to The Skell (Wrangbrook Dyke)

Spills 2025
27 (288 hours) · down 13% on 2024
Spills 2024
31 (331 hours)
Long-term average
38.3 spills a year (monitored since 2020)
Monitor uptime
100% of the year
Investigation
UWWTR investigation ongoing, Operational investigation completed
Improvement
No improvement action in reporting period
WFD catchment
The Skell from Source to Ea Beck (GB104027063280)
Outlet location
SE4959012540 (OS grid reference) · View on Apple Maps
EA ID / permit
YWS00927 · E744 · company name: UPTON WRANGBROOK/STW/3XDWF OVERFLOW

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024–25 [EA]. Infiltration of groundwater into sewers is taken as 0–40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies – environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 – per capita consumption
  3. HBF: Foul sewer design – historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 – CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Yorkshire Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.