Storm overflow register · Anglian Water

Elmswell sewage works: storm overflow spills 2025

Elmswell sewage treatment works, run by Anglian Water, has 1 monitored storm overflow discharging to River Sapiston. In 2025 it recorded 38 spills totalling 375 hours, against 32 spills and 276 hours in 2024. By hours spilling, it ranks 58 of 419 Anglian Water works, where 1 spilled longest.

Works size: 6,412 population equivalent (ELMSWELL STW, UWWTD 2018). Used for the spill volume estimate.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecElmswell Water…1 Jan 2025 17:15 GMT, 15 min1 Jan 2025 17:45 GMT, 15 min1 Jan 2025 18:00 GMT, 15 min5 Jan 2025 10:15 GMT, 3 h5 Jan 2025 15:00 GMT, 15 min5 Jan 2025 15:15 GMT, 5.3 h5 Jan 2025 20:30 GMT, 3.5 h6 Jan 2025 00:00 GMT, 9.5 h6 Jan 2025 16:00 GMT, 8 h7 Jan 2025 00:00 GMT, 6 h7 Jan 2025 06:00 GMT, 60 min7 Jan 2025 07:30 GMT, 6 h7 Jan 2025 13:30 GMT, 10.5 h8 Jan 2025 00:00 GMT, 3.3 h8 Jan 2025 03:30 GMT, 3 h8 Jan 2025 10:30 GMT, 15 min8 Jan 2025 11:00 GMT, 2 h8 Jan 2025 13:00 GMT, 15 min8 Jan 2025 13:15 GMT, 10.8 h9 Jan 2025 00:00 GMT, 2.5 h9 Jan 2025 02:30 GMT, 15 min9 Jan 2025 03:00 GMT, 15 min9 Jan 2025 12:00 GMT, 15 min9 Jan 2025 12:45 GMT, 45 min28 Jan 2025 10:45 GMT, 15 min28 Jan 2025 12:00 GMT, 6 h28 Jan 2025 18:15 GMT, 75 min28 Jan 2025 20:45 GMT, 15 min28 Jan 2025 21:00 GMT, 15 min28 Jan 2025 23:15 GMT, 30 min28 Jan 2025 23:45 GMT, 15 min29 Jan 2025 00:00 GMT, 24 h30 Jan 2025 00:00 GMT, 2.8 h31 Jan 2025 10:00 GMT, 30 min31 Jan 2025 13:15 GMT, 15 min31 Jan 2025 13:30 GMT, 30 min31 Jan 2025 14:00 GMT, 15 min31 Jan 2025 14:30 GMT, 15 min31 Jan 2025 16:30 GMT, 15 min1 Feb 2025 14:15 GMT, 30 min1 Feb 2025 15:00 GMT, 15 min1 Feb 2025 15:15 GMT, 15 min1 Feb 2025 15:45 GMT, 15 min1 Feb 2025 16:30 GMT, 15 min24 Feb 2025 10:00 GMT, 14 h25 Feb 2025 00:00 GMT, 4.3 h25 Feb 2025 04:30 GMT, 5.3 h25 Feb 2025 10:00 GMT, 12 h25 Feb 2025 22:00 GMT, 2 h26 Feb 2025 00:00 GMT, 30 min26 Feb 2025 00:30 GMT, 15 min26 Feb 2025 01:00 GMT, 90 min26 Feb 2025 02:30 GMT, 45 min26 Feb 2025 03:45 GMT, 15 min26 Feb 2025 04:15 GMT, 15 min26 Feb 2025 09:45 GMT, 15 min26 Feb 2025 10:15 GMT, 30 min26 Feb 2025 11:00 GMT, 2 h26 Feb 2025 13:00 GMT, 15 min26 Feb 2025 13:30 GMT, 10.5 h27 Feb 2025 00:00 GMT, 24 h28 Feb 2025 00:00 GMT, 45 min28 Feb 2025 00:45 GMT, 15 min28 Feb 2025 01:00 GMT, 5 h28 Feb 2025 09:30 GMT, 14.5 h1 Mar 2025 00:00 GMT, 2.5 h1 Mar 2025 02:30 GMT, 15 min1 Mar 2025 11:00 GMT, 13 h2 Mar 2025 00:00 GMT, 45 min2 Mar 2025 01:15 GMT, 15 min2 Mar 2025 11:30 GMT, 30 min2 Mar 2025 12:15 GMT, 5.5 h2 Mar 2025 18:00 GMT, 5.8 h2 Mar 2025 23:45 GMT, 15 min3 Mar 2025 00:00 GMT, 2.8 h14 Jun 2025 00:00 GMT, 15 min6 Jul 2025 18:45 GMT, 15 min4 Sep 2025 12:30 GMT, 15 min4 Oct 2025 07:30 GMT, 15 min4 Oct 2025 08:00 GMT, 15 min22 Oct 2025 21:30 GMT, 15 min22 Oct 2025 23:15 GMT, 15 min13 Nov 2025 23:15 GMT, 15 min14 Nov 2025 08:15 GMT, 15.8 h15 Nov 2025 00:00 GMT, 3.8 h15 Nov 2025 03:45 GMT, 15 min15 Nov 2025 04:15 GMT, 15 min15 Nov 2025 04:30 GMT, 45 min15 Nov 2025 05:30 GMT, 6.8 h15 Nov 2025 12:15 GMT, 15 min15 Nov 2025 14:15 GMT, 8.5 h19 Nov 2025 01:30 GMT, 15 min19 Nov 2025 20:15 GMT, 75 min19 Nov 2025 21:30 GMT, 30 min22 Nov 2025 17:15 GMT, 15 min22 Nov 2025 18:45 GMT, 5.3 h23 Nov 2025 00:00 GMT, 90 min23 Nov 2025 01:45 GMT, 15 min23 Nov 2025 02:00 GMT, 17.5 h23 Nov 2025 19:45 GMT, 75 min23 Nov 2025 21:00 GMT, 15 min23 Nov 2025 22:00 GMT, 2 h24 Nov 2025 00:00 GMT, 6.8 h24 Nov 2025 07:00 GMT, 9.5 h24 Nov 2025 17:30 GMT, 15 min24 Nov 2025 18:15 GMT, 4.8 h7 Dec 2025 20:15 GMT, 2.3 h9 Dec 2025 07:15 GMT, 3.3 h9 Dec 2025 11:45 GMT, 15 min9 Dec 2025 12:15 GMT, 75 min9 Dec 2025 13:45 GMT, 6.3 h9 Dec 2025 20:00 GMT, 4 h10 Dec 2025 00:00 GMT, 2 h10 Dec 2025 03:00 GMT, 15 min10 Dec 2025 07:30 GMT, 7 h18 Dec 2025 12:45 GMT, 15 min18 Dec 2025 13:00 GMT, 15 min18 Dec 2025 19:15 GMT, 4.8 h19 Dec 2025 00:00 GMT, 105 min19 Dec 2025 09:45 GMT, 30 min19 Dec 2025 10:30 GMT, 4.5 h

Estimated spill volume by month, 2025

Hours spilling each month × the estimated spill rate for a works of this size. The bars are central estimates and the whiskers show the low–high range. Method.

010k20k30k40kJan 2025: 115 h spilling ≈ 12,613 m³ (range 5,024–31,664 m³)JanFeb 2025: 101 h spilling ≈ 11,042 m³ (range 4,398–27,720 m³)FebMar 2025: 32 h spilling ≈ 3,461 m³ (range 1,378–8,688 m³)MarApr 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)AprMay 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)MayJun 2025: 0.2 h spilling ≈ 22 m³ (range 8.8–55 m³)JunJul 2025: 0.2 h spilling ≈ 22 m³ (range 8.8–55 m³)JulAug 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)AugSep 2025: 0.2 h spilling ≈ 22 m³ (range 8.8–55 m³)SepOct 2025: 1.0 h spilling ≈ 110 m³ (range 44–276 m³)OctNov 2025: 88 h spilling ≈ 9,668 m³ (range 3,851–24,272 m³)NovDec 2025: 39 h spilling ≈ 4,230 m³ (range 1,685–10,619 m³)Dec
Cubic metres (m³), estimate. Hours are measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDurationEstimated volume
27 Feb 2025, 00:00Elmswell Water Recycling Centre1.0 days1,050 – 6,620 m³
29 Jan 2025, 00:00Elmswell Water Recycling Centre1.0 days1,050 – 6,620 m³
23 Nov 2025, 02:00Elmswell Water Recycling Centre17.5 h766 – 4,827 m³
14 Nov 2025, 08:15Elmswell Water Recycling Centre15.8 h689 – 4,344 m³
28 Feb 2025, 09:30Elmswell Water Recycling Centre14.5 h635 – 3,999 m³

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

Volume, central estimate41,200 m³range 16,411 – 103,434 m³
In litres41.2 millionrange 16.4 million – 103.4 million L
Olympic swimming pools16at 2,500 m³ each
Organic load, as people's raw sewage61,800person-days of untreated BOD

Assumed spill rate while spilling: 12.2 – 76.6 L/s (central 30.5 L/s), from a dry-weather flow of 12.2 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 656 kg3,708 kg20,687 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 1,723 kg17,510 kg74,576 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 31 kg260 kg962 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3–9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 20 kg107 kg559 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 1.6 trillion organisms41.2 trillion organisms1.0 × 10¹⁵ organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Elmswell Water Recycling Centre

Storm tank at sewage works · discharges to River Sapiston

Spills 2025
38 (375 hours) · up 19% on 2024
Spills 2024
32 (276 hours)
Long-term average
50.8 spills a year (monitored since 2021)
Monitor uptime
100% of the year
High-spill reason (company)
Not asset maintenance - Hydraulic capacity
Investigation
Env Act (SODRP) investigation ongoing, Operational investigation completed
Improvement
Operational improvement completed
WFD catchment
Sapiston (GB105033043280)
Outlet location
TL9785063270 (OS grid reference) · View on Apple Maps
EA ID / permit
AWS00402 · ASCNF1065 · company name: ELMSWELL STW

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024–25 [EA]. Infiltration of groundwater into sewers is taken as 0–40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies – environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 – per capita consumption
  3. HBF: Foul sewer design – historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 – CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Anglian Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.