Storm overflow register · Anglian Water

Great Oxendon sewage works: storm overflow spills 2025

Great Oxendon sewage treatment works, run by Anglian Water, has 1 monitored storm overflow discharging to River Ise. In 2025 it recorded 88 spills totalling 1,548 hours, against 154 spills and 3,206 hours in 2024. By hours spilling, it ranks 4 of 419 Anglian Water works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecGreat Oxendon STW8 spills, 172.3 h, 1 Jan to 8 Jan2 spills, 15.9 h, 16 Jan to 17 Jan4 spills, 94.8 h, 27 Jan to 31 Jan3 spills, 72 h, 1 Feb to 4 Feb2 spills, 48 h, 5 Feb to 7 Feb4 spills, 94.9 h, 9 Feb to 13 Feb4 spills, 81.4 h, 15 Feb to 19 Feb3 spills, 30.1 h, 20 Feb to 21 Feb8 spills, 117.8 h, 23 Feb to 1 Mar3 spills, 19.4 h, 23 Apr to 24 Apr2 spills, 22 h, 27 May to 28 May3 spills, 47.8 h, 6 Jul to 8 Jul2 spills, 6.7 h, 29 Aug to 29 Aug3 spills, 25.6 h, 3 Sep to 4 Sep2 spills, 14.2 h, 14 Sep to 15 Sep1 Nov 2025 02:06 GMT, 6.9 h10 Nov 2025 13:26 GMT, 7.3 h12 Nov 2025 09:12 GMT, 3.7 h2 spills, 33.5 h, 14 Nov to 15 Nov3 spills, 37.8 h, 22 Nov to 24 Nov29 Nov 2025 11:14 GMT, 90 min4 spills, 57.5 h, 1 Dec to 3 Dec24 spills, 537.1 h, 4 Dec to 27 Dec

Hours spilling by month, 2025

0200400600Jan 2025: 283 hours spillingJanFeb 2025: 444 hours spillingFebMar 2025: 0.0 hours spillingMarApr 2025: 19 hours spillingAprMay 2025: 22 hours spillingMayJun 2025: 0.0 hours spillingJunJul 2025: 48 hours spillingJulAug 2025: 6.7 hours spillingAugSep 2025: 40 hours spillingSepOct 2025: 0.0 hours spillingOctNov 2025: 91 hours spillingNovDec 2025: 595 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
26 Dec 2025, 00:00Great Oxendon STW1.0 days
25 Dec 2025, 00:00Great Oxendon STW1.0 days
24 Dec 2025, 00:00Great Oxendon STW1.0 days
23 Dec 2025, 00:00Great Oxendon STW1.0 days
22 Dec 2025, 00:00Great Oxendon STW1.0 days

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate26,528 m³range 10,566 - 66,598 m³
In litres26.5 millionrange 10.6 million - 66.6 million L
Olympic swimming pools11at 2,500 m³ each
Organic load, as people's raw sewage39,791person-days of untreated BOD

Assumed spill rate while spilling: 1.9 - 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 423 kg2,387 kg13,320 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 1,109 kg11,274 kg48,017 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 20 kg167 kg619 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3-9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 13 kg69 kg360 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 1.1 trillion organisms26.5 trillion organisms666.0 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Great Oxendon STW

Storm tank at sewage works · discharges to River Ise

Spills 2025
88 (1,548 hours) · down 43% on 2024
Spills 2024
154 (3,206 hours)
Long-term average
109.0 spills a year (monitored since 2022)
Monitor uptime
95% of the year
High-spill reason (company)
Not Applicable - Ongoing investigation
Investigation
Env Act (SODRP) investigation ongoing, Operational investigation ongoing
Improvement
Env Act (SODRP) improvement ongoing
WFD catchment
Ise - Upper (GB105032045200)
Outlet location
SP7360082300 (OS grid reference) · View on Apple Maps
EA ID / permit
AWS00505 · AWNNF13652

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024-25 [EA]. Infiltration of groundwater into sewers is taken as 0-40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies - environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 - per capita consumption
  3. HBF: Foul sewer design - historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 - CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Anglian Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.