Storm overflow register · Anglian Water

Marston Moretaine sewage works: storm overflow spills 2025

Marston Moretaine sewage treatment works, run by Anglian Water, has 1 monitored storm overflow discharging to Marston Brook. In 2025 it recorded 76 spills totalling 914 hours, against 147 spills and 2,253 hours in 2024. By hours spilling, it ranks 14 of 419 Anglian Water works, where 1 spilled longest.

Works size: 11,181 population equivalent (MARSTON MORETAINE STW, UWWTD 2018). Used for the spill volume estimate.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecMarston Moretaine WRC512 spills, 534.3 h, 1 Jan to 4 Feb2 spills, 2.2 h, 5 Feb to 5 Feb2 spills, 0.7 h, 6 Feb to 6 Feb127 spills, 125.8 h, 7 Feb to 17 Feb2 spills, 2.5 h, 18 Feb to 19 Feb5 spills, 3.7 h, 19 Feb to 19 Feb4 spills, 9 h, 21 Feb to 22 Feb20 spills, 89.4 h, 23 Feb to 28 Feb10 spills, 14.5 h, 23 Apr to 23 Apr20 spills, 10.1 h, 6 Jul to 7 Jul4 spills, 1.8 h, 3 Sep to 3 Sep29 Sep 2025 09:22 GMT, 4 min7 spills, 70.9 h, 13 Nov to 16 Nov9 spills, 0.8 h, 29 Nov to 29 Nov4 spills, 3.2 h, 5 Dec to 5 Dec6 spills, 0.3 h, 7 Dec to 7 Dec77 spills, 14.1 h, 9 Dec to 9 Dec7 spills, 30.4 h, 18 Dec to 19 Dec

Estimated spill volume by month, 2025

Hours spilling each month × the estimated spill rate for a works of this size. The bars are central estimates and the whiskers show the low-high range. Method.

0100k200k300kJan 2025: 501 h spilling ≈ 95,924 m³ (range 38,209-240,821 m³)JanFeb 2025: 267 h spilling ≈ 51,114 m³ (range 20,360-128,323 m³)FebMar 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0-0.0 m³)MarApr 2025: 15 h spilling ≈ 2,778 m³ (range 1,106-6,974 m³)AprMay 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0-0.0 m³)MayJun 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0-0.0 m³)JunJul 2025: 10 h spilling ≈ 1,935 m³ (range 771-4,858 m³)JulAug 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0-0.0 m³)AugSep 2025: 1.9 h spilling ≈ 364 m³ (range 145-914 m³)SepOct 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0-0.0 m³)OctNov 2025: 72 h spilling ≈ 13,736 m³ (range 5,471-34,486 m³)NovDec 2025: 48 h spilling ≈ 9,196 m³ (range 3,663-23,087 m³)Dec
Cubic metres (m³), estimate. Hours are measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDurationEstimated volume
15 Nov 2025, 00:00Marston Moretaine WRC1.0 days1,831 - 11,543 m³
14 Nov 2025, 00:00Marston Moretaine WRC1.0 days1,831 - 11,543 m³
27 Feb 2025, 00:00Marston Moretaine WRC1.0 days1,831 - 11,543 m³
29 Jan 2025, 00:00Marston Moretaine WRC1.0 days1,831 - 11,543 m³
8 Jan 2025, 00:00Marston Moretaine WRC1.0 days1,831 - 11,543 m³

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

Volume, central estimate175,047 m³range 69,725 - 439,462 m³
In litres175.0 millionrange 69.7 million - 439.5 million L
Olympic swimming pools70at 2,500 m³ each
Organic load, as people's raw sewage262,570person-days of untreated BOD

Assumed spill rate while spilling: 21.2 - 133.6 L/s (central 53.2 L/s), from a dry-weather flow of 21.2 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 2,789 kg15,754 kg87,892 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 7,321 kg74,395 kg316,852 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 132 kg1,103 kg4,087 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3-9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 84 kg455 kg2,373 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 7.0 trillion organisms175.0 trillion organisms4.4 × 10¹⁵ organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Marston Moretaine WRC

Storm tank at sewage works · discharges to Marston Brook

Spills 2025
76 (914 hours) · down 48% on 2024
Spills 2024
147 (2,253 hours)
Long-term average
108.7 spills a year (monitored since 2023)
Monitor uptime
100% of the year
High-spill reason (company)
Performance - Asset configuration (e.g. PS/rising main/storm tanks)
Investigation
Env Act (SODRP) investigation ongoing, Operational investigation completed
Improvement
Operational improvement ongoing
WFD catchment
Elstow Brook (US Shortstown) (GB105033038050)
Outlet location
TL0024041960 (OS grid reference) · View on Apple Maps
EA ID / permit
AWS00823 · AW1NF3013 · company name: MARSTON MORETAINE STW

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024-25 [EA]. Infiltration of groundwater into sewers is taken as 0-40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies - environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 - per capita consumption
  3. HBF: Foul sewer design - historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 - CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Anglian Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.