Storm overflow register · Anglian Water

Skellingthorpe sewage works: storm overflow spills 2025

Skellingthorpe sewage treatment works, run by Anglian Water, has 1 monitored storm overflow discharging to Skellingthorpe Main Drain. In 2025 it recorded 28 spills totalling 420 hours, against 40 spills and 573 hours in 2024. By hours spilling, it ranks 53 of 419 Anglian Water works, where 1 spilled longest.

Works size: 4,676 population equivalent (SKELLINGTHORPE STW, UWWTD 2018). Used for the spill volume estimate.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecSkellingthorpe STW5 Jan 2025 18:45 GMT, 5.3 h6 Jan 2025 00:00 GMT, 24 h7 Jan 2025 00:00 GMT, 24 h8 Jan 2025 00:00 GMT, 24 h9 Jan 2025 00:00 GMT, 90 min10 Nov 2025 17:30 GMT, 6.5 h11 Nov 2025 00:00 GMT, 3 h11 Nov 2025 07:45 GMT, 7 h11 Nov 2025 23:45 GMT, 15 min12 Nov 2025 00:00 GMT, 24 h13 Nov 2025 00:00 GMT, 105 min14 Nov 2025 07:45 GMT, 16.3 h15 Nov 2025 00:00 GMT, 24 h16 Nov 2025 00:00 GMT, 24 h17 Nov 2025 00:00 GMT, 24 h19 Nov 2025 10:45 GMT, 13.3 h20 Nov 2025 00:00 GMT, 75 min20 Nov 2025 01:15 GMT, 15 min29 Nov 2025 19:00 GMT, 5 h30 Nov 2025 00:00 GMT, 24 h1 Dec 2025 00:00 GMT, 3.3 h1 Dec 2025 08:30 GMT, 15.5 h2 Dec 2025 00:00 GMT, 90 min5 Dec 2025 03:30 GMT, 20.5 h6 Dec 2025 00:00 GMT, 24 h7 Dec 2025 00:00 GMT, 2.8 h7 Dec 2025 12:45 GMT, 11.3 h8 Dec 2025 00:00 GMT, 105 min8 Dec 2025 21:15 GMT, 2.8 h9 Dec 2025 00:00 GMT, 60 min9 Dec 2025 05:15 GMT, 18.8 h10 Dec 2025 00:00 GMT, 14.3 h10 Dec 2025 14:15 GMT, 30 min10 Dec 2025 14:45 GMT, 45 min10 Dec 2025 15:30 GMT, 15 min10 Dec 2025 18:15 GMT, 3 h10 Dec 2025 21:45 GMT, 45 min18 Dec 2025 23:15 GMT, 45 min19 Dec 2025 00:00 GMT, 24 h20 Dec 2025 00:00 GMT, 105 min20 Dec 2025 01:45 GMT, 45 min20 Dec 2025 08:45 GMT, 12.3 h22 Dec 2025 19:00 GMT, 4.5 h

Estimated spill volume by month, 2025

Hours spilling each month × the estimated spill rate for a works of this size. The bars are central estimates and the whiskers show the low–high range. Method.

010k20k30k40kJan 2025: 79 h spilling ≈ 6,314 m³ (range 2,515–15,850 m³)JanFeb 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)FebMar 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)MarApr 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)AprMay 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)MayJun 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)JunJul 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)JulAug 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)AugSep 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)SepOct 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)OctNov 2025: 175 h spilling ≈ 13,981 m³ (range 5,569–35,100 m³)NovDec 2025: 167 h spilling ≈ 13,340 m³ (range 5,314–33,491 m³)Dec
Cubic metres (m³), estimate. Hours are measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDurationEstimated volume
19 Dec 2025, 00:00Skellingthorpe STW1.0 days766 – 4,828 m³
6 Dec 2025, 00:00Skellingthorpe STW1.0 days766 – 4,828 m³
30 Nov 2025, 00:00Skellingthorpe STW1.0 days766 – 4,828 m³
17 Nov 2025, 00:00Skellingthorpe STW1.0 days766 – 4,828 m³
16 Nov 2025, 00:00Skellingthorpe STW1.0 days766 – 4,828 m³

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

Volume, central estimate33,635 m³range 13,397 – 84,441 m³
In litres33.6 millionrange 13.4 million – 84.4 million L
Olympic swimming pools13at 2,500 m³ each
Organic load, as people's raw sewage50,452person-days of untreated BOD

Assumed spill rate while spilling: 8.9 – 55.9 L/s (central 22.3 L/s), from a dry-weather flow of 8.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 536 kg3,027 kg16,888 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 1,407 kg14,295 kg60,882 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 25 kg212 kg785 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3–9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 16 kg87 kg456 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 1.3 trillion organisms33.6 trillion organisms844.4 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Skellingthorpe STW

Storm tank at sewage works · discharges to Skellingthorpe Main Drain

Spills 2025
28 (420 hours) · down 30% on 2024
Spills 2024
40 (573 hours)
Long-term average
34.0 spills a year (monitored since 2021)
Monitor uptime
100% of the year
Investigation
Env Act (SODRP) investigation ongoing
Improvement
No improvement action in reporting period
WFD catchment
Skellingthorpe Main Drain (GB105030062390)
Outlet location
SK9369072650 (OS grid reference) · View on Apple Maps
EA ID / permit
AWS01140 · ANNNF1192

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024–25 [EA]. Infiltration of groundwater into sewers is taken as 0–40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies – environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 – per capita consumption
  3. HBF: Foul sewer design – historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 – CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Anglian Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.