Storm overflow register · Anglian Water

Ulceby sewage works: storm overflow spills 2025

Ulceby sewage treatment works, run by Anglian Water, has 1 monitored storm overflow discharging to tributary Skitter Beck. In 2025 it recorded 36 spills totalling 506 hours, against 40 spills and 551 hours in 2024. By hours spilling, it ranks 39 of 419 Anglian Water works, where 1 spilled longest.

Works size: 2,136 population equivalent (ULCEBY STW, UWWTD 2018). Used for the spill volume estimate.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecUlceby STW5 Jan 2025 09:00 GMT, 15 h6 Jan 2025 00:00 GMT, 24 h7 Jan 2025 00:00 GMT, 24 h8 Jan 2025 00:00 GMT, 6 h20 Jul 2025 14:50 GMT, 9.2 h21 Jul 2025 00:00 GMT, 96 min20 Sep 2025 17:54 GMT, 6.1 h21 Sep 2025 00:00 GMT, 6.9 h28 Sep 2025 09:20 GMT, 4.8 h3 Oct 2025 17:50 GMT, 3.1 h3 Oct 2025 21:38 GMT, 74 min23 Oct 2025 04:28 GMT, 10.2 h10 Nov 2025 14:56 GMT, 9.1 h11 Nov 2025 00:00 GMT, 24 h12 Nov 2025 00:00 GMT, 7.8 h14 Nov 2025 09:42 GMT, 14.3 h15 Nov 2025 00:00 GMT, 24 h16 Nov 2025 00:00 GMT, 24 h17 Nov 2025 00:00 GMT, 4 h19 Nov 2025 04:16 GMT, 19.7 h20 Nov 2025 00:00 GMT, 86 min23 Nov 2025 18:32 GMT, 5.5 h24 Nov 2025 00:00 GMT, 13.2 h24 Nov 2025 14:00 GMT, 10 h25 Nov 2025 00:00 GMT, 38 min29 Nov 2025 07:10 GMT, 16.8 h30 Nov 2025 00:00 GMT, 24 h1 Dec 2025 00:00 GMT, 24 h2 Dec 2025 00:00 GMT, 24 h3 Dec 2025 00:00 GMT, 6 h4 Dec 2025 19:12 GMT, 4.8 h5 Dec 2025 00:00 GMT, 24 h6 Dec 2025 00:00 GMT, 24 h7 Dec 2025 00:00 GMT, 4 h9 Dec 2025 06:40 GMT, 17.3 h10 Dec 2025 00:00 GMT, 12.7 h16 Dec 2025 09:08 GMT, 14.9 h17 Dec 2025 00:00 GMT, 4.9 h18 Dec 2025 15:38 GMT, 8.4 h19 Dec 2025 00:00 GMT, 24 h20 Dec 2025 00:00 GMT, 2.2 h

Estimated spill volume by month, 2025

Hours spilling each month × the estimated spill rate for a works of this size. The bars are central estimates and the whiskers show the low–high range. Method.

05,00010k15k20kJan 2025: 69 h spilling ≈ 2,525 m³ (range 1,006–6,340 m³)JanFeb 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)FebMar 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)MarApr 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)AprMay 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)MayJun 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)JunJul 2025: 11 h spilling ≈ 395 m³ (range 157–992 m³)JulAug 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)AugSep 2025: 18 h spilling ≈ 651 m³ (range 259–1,636 m³)SepOct 2025: 15 h spilling ≈ 531 m³ (range 211–1,332 m³)OctNov 2025: 199 h spilling ≈ 7,265 m³ (range 2,894–18,239 m³)NovDec 2025: 195 h spilling ≈ 7,144 m³ (range 2,846–17,936 m³)Dec
Cubic metres (m³), estimate. Hours are measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDurationEstimated volume
19 Dec 2025, 00:00Ulceby STW1.0 days350 – 2,205 m³
6 Dec 2025, 00:00Ulceby STW1.0 days350 – 2,205 m³
5 Dec 2025, 00:00Ulceby STW1.0 days350 – 2,205 m³
2 Dec 2025, 00:00Ulceby STW1.0 days350 – 2,205 m³
1 Dec 2025, 00:00Ulceby STW1.0 days350 – 2,205 m³

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

Volume, central estimate18,508 m³range 7,372 – 46,466 m³
In litres18.5 millionrange 7.4 million – 46.5 million L
Olympic swimming pools7.4at 2,500 m³ each
Organic load, as people's raw sewage27,762person-days of untreated BOD

Assumed spill rate while spilling: 4.0 – 25.5 L/s (central 10.2 L/s), from a dry-weather flow of 4.0 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 295 kg1,666 kg9,293 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 774 kg7,866 kg33,502 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 14 kg117 kg432 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3–9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 8.8 kg48 kg251 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 737.2 billion organisms18.5 trillion organisms464.7 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Ulceby STW

Storm tank at sewage works · discharges to tributary Skitter Beck

Spills 2025
36 (506 hours) · down 10% on 2024
Spills 2024
40 (551 hours)
Long-term average
58.0 spills a year (monitored since 2022)
Monitor uptime
100% of the year
High-spill reason (company)
Performance - Partial / no capacity due to blockage or restriction (e.g. roots / grid) - maintenance issue
Investigation
Env Act (SODRP) investigation ongoing
Improvement
Env Act (SODRP) improvement ongoing
WFD catchment
Skitter Beck / East Halton Beck (GB104029067655)
Outlet location
TA1115016540 (OS grid reference) · View on Apple Maps
EA ID / permit
AWS01414 · ANNNF13085

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024–25 [EA]. Infiltration of groundwater into sewers is taken as 0–40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies – environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 – per capita consumption
  3. HBF: Foul sewer design – historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 – CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Anglian Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.