Storm overflow register · Northumbrian Water

Middleton In Teesdale sewage works: storm overflow spills 2025

Middleton In Teesdale sewage treatment works, run by Northumbrian Water, has 2 monitored storm overflows discharging to River Tees. In 2025 they recorded 81 spills totalling 760 hours, against 156 spills and 1,731 hours in 2024. By hours spilling, it ranks 17 of 183 Northumbrian Water works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecMiddleton-in-Teesdale…2 spills, 44.3 h, 1 Jan to 2 Jan5 Jan 2025 13:29 GMT, 34 h2 spills, 15.8 h, 13 Jan to 14 Jan24 Jan 2025 02:59 GMT, 12.3 h7 spills, 31 h, 26 Jan to 28 Jan2 spills, 4.8 h, 4 Feb to 4 Feb44 spills, 74.8 h, 10 Feb to 17 Feb2 spills, 6.3 h, 19 Feb to 20 Feb21 Feb 2025 18:44 GMT, 90 min3 spills, 15 h, 24 Feb to 25 Feb2 spills, 7.6 h, 22 Mar to 23 Mar29 May 2025 07:59 GMT, 20 h3 Jun 2025 08:47 GMT, 15.7 h4 Jun 2025 22:11 GMT, 4.8 h9 Jun 2025 21:35 GMT, 3.8 h2 spills, 4.8 h, 15 Jul to 15 Jul2 spills, 3.6 h, 4 Aug to 4 Aug3 spills, 19.5 h, 20 Sep to 21 Sep3 spills, 9.2 h, 2 Oct to 4 Oct19 Oct 2025 20:09 GMT, 4.3 h4 spills, 11.2 h, 3 Nov to 4 Nov5 Nov 2025 09:17 GMT, 92 min11 Nov 2025 20:47 GMT, 82 min3 spills, 69 h, 12 Nov to 15 Nov2 spills, 3.6 h, 23 Nov to 23 Nov4 spills, 13.1 h, 28 Nov to 29 Nov7 spills, 24.8 h, 1 Dec to 2 Dec8 spills, 18.1 h, 5 Dec to 6 Dec25 spills, 97.9 h, 7 Dec to 12 Dec16 spills, 179.1 h, 14 Dec to 23 DecMiddleton-in-Teesdale…1 Jan 2025 03:44 GMT, 105 min22 Mar 2025 18:03 GMT, 2 min2 spills, 0.2 h, 4 Jun to 4 Jun21 Jun 2025 19:37 GMT, 2 min2 spills, 0.1 h, 20 Jul to 21 Jul15 spills, 2.7 h, 12 Nov to 13 Nov23 Nov 2025 06:37 GMT, 12 min28 Nov 2025 11:37 GMT, 40 min7 Dec 2025 16:57 GMT, 4 min4 spills, 1 h, 10 Dec to 10 Dec2 spills, 0.5 h, 17 Dec to 18 Dec

Hours spilling by month, 2025

0100200300400Jan 2025: 139 hours spillingJanFeb 2025: 102 hours spillingFebMar 2025: 7.6 hours spillingMarApr 2025: 0.0 hours spillingAprMay 2025: 20 hours spillingMayJun 2025: 25 hours spillingJunJul 2025: 4.9 hours spillingJulAug 2025: 3.6 hours spillingAugSep 2025: 20 hours spillingSepOct 2025: 14 hours spillingOctNov 2025: 103 hours spillingNovDec 2025: 322 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
17 Dec 2025, 15:49Middleton-in-Teesdale STW5.4 days
9 Dec 2025, 04:13Middleton-in-Teesdale STW2.9 days
12 Nov 2025, 21:49Middleton-in-Teesdale STW2.8 days
1 Jan 2025, 00:00Middleton-in-Teesdale STW1.7 days
5 Jan 2025, 13:29Middleton-in-Teesdale STW1.4 days

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate13,019 m³range 5,186 - 32,684 m³
In litres13.0 millionrange 5.2 million - 32.7 million L
Olympic swimming pools5.2at 2,500 m³ each
Organic load, as people's raw sewage19,528person-days of untreated BOD

Assumed spill rate while spilling: 1.9 - 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 207 kg1,172 kg6,537 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 544 kg5,533 kg23,565 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 9.9 kg82 kg304 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3-9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 6.2 kg34 kg176 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 518.6 billion organisms13.0 trillion organisms326.8 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Middleton-in-Teesdale STW

Storm tank at sewage works · discharges to River Tees

Spills 2025
70 (753 hours) · down 46% on 2024
Spills 2024
129 (1,710 hours)
Long-term average
113.7 spills a year (monitored since 2021)
Monitor uptime
99% of the year
High-spill reason (company)
Performance - SW Infiltration
Investigation
Operational investigation completed
Improvement
Operational improvement ongoing
WFD catchment
Tees from Maize Beck to Percy Beck (GB103025072511)
Outlet location
NY9526224911 (OS grid reference) · View on Apple Maps
EA ID / permit
NWL00878 · 25/01/0919

Middleton-in-Teesdale STW

Inlet overflow at sewage works · discharges to River Tees

Spills 2025
11 (7.3 hours) · down 59% on 2024
Spills 2024
27 (21 hours)
Long-term average
22.0 spills a year (monitored since 2013)
Monitor uptime
88% of the year · Sensor failure / issue
Investigation
Operational investigation completed
Improvement
Operational improvement ongoing
WFD catchment
Tees from Maize Beck to Percy Beck (GB103025072511)
Outlet location
NY9513524887 (OS grid reference) · View on Apple Maps
EA ID / permit
NWL00877 · 25/01/0919

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024-25 [EA]. Infiltration of groundwater into sewers is taken as 0-40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies - environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 - per capita consumption
  3. HBF: Foul sewer design - historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 - CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Northumbrian Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.