Cotherstone STW Inlet overflow at sewage works
- Sewage works
- Cotherstone
- EA ID / permit
- NWL00332 · 25/01/0920
- Outlet location
- NZ0071020010 (OS grid reference) · View on Apple Maps
- WFD catchment
- Balder Catchment (trib of Tees) (GB103025072240)
- 2024 spills / hours
- 228 / 4,350
- Long-term average
- 204.0 spills a year (monitored since 2021)
- High-spill reason (company)
- Performance - SW Infiltration
- Investigation
- Env Act (SODRP) investigation ongoing, Operational investigation completed
- Improvement
- Operational improvement ongoing
- Volume & pollution
- Estimate from 2,197 hours spilling →
|
River Balder |
161 |
2,197 |
down 29% |
100% |
Allendale STW Storm tank at sewage works
- Sewage works
- Allendale
- EA ID / permit
- NWL00034 · 232/1118
- Outlet location
- NY8278557056 (OS grid reference) · View on Apple Maps
- WFD catchment
- Allen from Source to West Allen (GB103023074710)
- 2024 spills / hours
- 202 / 3,981
- Long-term average
- 145.7 spills a year (monitored since 2020)
- High-spill reason (company)
- Performance - SW Infiltration
- Investigation
- Operational investigation ongoing
- Improvement
- Operational improvement ongoing
- Volume & pollution
- Estimate from 1,865 hours spilling →
|
River East Allen |
106 |
1,865 |
down 48% |
98% |
Western Area STW Storm tank at sewage works
- Sewage works
- Western Area
- EA ID / permit
- NWL01501 · 241/1146
- Outlet location
- NY9241337903 (OS grid reference) · View on Apple Maps
- WFD catchment
- Wear from Middlehope Burn to Houselop Beck (GB103024077461)
- 2024 spills / hours
- 135 / 2,060
- Long-term average
- 100.2 spills a year (monitored since 2020)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- Env Act (SODRP) investigation ongoing, Operational investigation ongoing
- Improvement
- Operational improvement ongoing
- Volume & pollution
- Estimate from 1,822 hours spilling →
|
River Wear |
107 |
1,822 |
down 21% |
100% |
Otterburn STW Storm tank at sewage works
- Sewage works
- Otterburn
- EA ID / permit
- NWL00987 · 231/1087
- Outlet location
- NY8911592613 (OS grid reference) · View on Apple Maps
- WFD catchment
- Rede from Bellshiel Burn to N Tyne (GB103023075320)
- 2024 spills / hours
- 88 / 1,229
- Long-term average
- 109.3 spills a year (monitored since 2020)
- High-spill reason (company)
- Performance - SW Infiltration
- Investigation
- Operational investigation ongoing
- Improvement
- Operational improvement ongoing
- Volume & pollution
- Estimate from 1,816 hours spilling →
|
River Rede |
120 |
1,816 |
up 36% |
100% |
Felton STW Storm tank at sewage works
- Sewage works
- Felton
- EA ID / permit
- NWL00544 · 223/0993
- Outlet location
- NU1912800567&NU1915300559 (OS grid reference) · View on Apple Maps
- WFD catchment
- Coquet from Forest Burn to Tidal Limit (GB103022076693)
- 2024 spills / hours
- 216 / 3,692
- Long-term average
- 132.8 spills a year (monitored since 2020)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- Env Act (SODRP) investigation ongoing, Operational investigation ongoing
- Improvement
- Operational improvement ongoing
- Volume & pollution
- Estimate from 1,454 hours spilling →
|
Coquet |
109 |
1,454 |
down 50% |
97% |
Glasshouse Street PS Storm discharge at pumping station
- EA ID / permit
- NWL00592 · 235/1767
- Outlet location
- NZ2713563481 (OS grid reference) · View on Apple Maps
- WFD catchment
- TYNE (GB510302310200)
- 2024 spills / hours
- 180 / 2,019
- Long-term average
- 145.3 spills a year (monitored since 2013)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- Operational investigation ongoing
- Improvement
- Operational improvement ongoing
- Volume & pollution
- Estimate from 1,353 hours spilling →
|
River Tyne, North Sea |
128 |
1,353 |
down 29% |
96% |
Graythorp STW Inlet overflow at sewage works
- Sewage works
- Graythorp
- EA ID / permit
- NWL00612 · 25/04/1758
- Outlet location
- NZ5228926460 (OS grid reference) · View on Apple Maps
- WFD catchment
- TEES (GB510302509900)
- 2024 spills / hours
- 136 / 1,932
- Long-term average
- 134.3 spills a year (monitored since 2020)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- Env Act (SODRP) investigation ongoing, Operational investigation ongoing
- Improvement
- Operational improvement ongoing
- Volume & pollution
- Estimate from 1,349 hours spilling →
|
Greatham Creek/Seaton Channel |
94 |
1,349 |
down 31% |
97% |
Howdon STW Inlet overflow at sewage works
- Sewage works
- Howdon
- EA ID / permit
- NWL00714 · 235/1695
- Outlet location
- NZ3370066130 (OS grid reference) · View on Apple Maps
- WFD catchment
- TYNE (GB510302310200)
- 2024 spills / hours
- 214 / 2,523
- Long-term average
- 173.0 spills a year (monitored since 2020)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- Env Act (SODRP) investigation ongoing
- Improvement
- No improvement action in reporting period
- Volume & pollution
- Estimate from 1,238 hours spilling →
|
River Tyne Saline Estuary |
120 |
1,238 |
down 44% |
100% |
Swainby STW Storm tank at sewage works
- Sewage works
- Swainby
- EA ID / permit
- NWL01333 · 254/1962
- Outlet location
- NZ4777902920 (OS grid reference) · View on Apple Maps
- WFD catchment
- Potto Beck Catchment (trib of Leven) (GB103025071850)
- 2024 spills / hours
- 79 / 916
- Long-term average
- 37.6 spills a year (monitored since 2021)
- High-spill reason (company)
- Performance - SW Infiltration
- Investigation
- Operational investigation ongoing
- Improvement
- Operational improvement ongoing
- Volume & pollution
- Estimate from 1,236 hours spilling →
|
Potto Beck |
72 |
1,236 |
down 9% |
100% |
Milfield Sewage Treatment Works Storm tank at sewage works
- Sewage works
- Milfield
- EA ID / permit
- NWL00881 · 210/1327
- Outlet location
- NT9388034340 (OS grid reference) · View on Apple Maps
- WFD catchment
- Till from Glen to River Tweed (GB102021073050)
- 2024 spills / hours
- 261 / 5,365
- Long-term average
- 172.0 spills a year (monitored since 2024)
- High-spill reason (company)
- Performance - SW Infiltration
- Investigation
- Operational investigation completed
- Improvement
- No improvement action in reporting period
- Volume & pollution
- Estimate from 1,193 hours spilling →
|
Unnamed Trib River Till |
83 |
1,193 |
down 68% |
99% |
Wagonway Road SPS Storm discharge at pumping station
- EA ID / permit
- NWL01442 · 235/1745
- Outlet location
- NZ3153065824 (OS grid reference) · View on Apple Maps
- WFD catchment
- TYNE (GB510302310200)
- 2024 spills / hours
- 179 / 2,946
- Long-term average
- 145.8 spills a year (monitored since 2020)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- Operational investigation ongoing
- Improvement
- No improvement action in reporting period
- Volume & pollution
- Estimate from 1,085 hours spilling →
|
River Tyne Saline Estuary |
100 |
1,085 |
down 44% |
100% |
Butterknowle Sewage Treatment Works Storm tank at sewage works
- Sewage works
- Butterknowle
- EA ID / permit
- NWL00231 · 242/1070
- Outlet location
- NZ1178325593 (OS grid reference) · View on Apple Maps
- WFD catchment
- Gaunless from Source to Hummer Beck (GB103024072690)
- 2024 spills / hours
- 130 / 1,688
- Long-term average
- 108.8 spills a year (monitored since 2020)
- High-spill reason (company)
- Performance - SW Infiltration
- Investigation
- Env Act (SODRP) investigation ongoing, Operational investigation ongoing
- Improvement
- No improvement action in reporting period
- Volume & pollution
- Estimate from 1,066 hours spilling →
|
Gaunless |
82 |
1,066 |
down 37% |
99% |
Tow Law STW Storm tank at sewage works
- Sewage works
- Tow Law
- EA ID / permit
- NWL01396 · 241/1106
- Outlet location
- NZ1135638568 (OS grid reference) · View on Apple Maps
- WFD catchment
- Houselop Beck from Source to Wear (GB103024077450)
- 2024 spills / hours
- 41 / 160
- Long-term average
- 60.2 spills a year (monitored since 2020)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- Env Act (SODRP) investigation ongoing, Operational investigation completed
- Improvement
- No improvement action in reporting period
- Volume & pollution
- Estimate from 1,029 hours spilling →
|
Heatherley Clough |
74 |
1,029 |
up 80% |
100% |
Nenthead STW Storm tank at sewage works
- Sewage works
- Nenthead
- EA ID / permit
- NWL00924 · 232/1097
- Outlet location
- NY7768144305 (OS grid reference) · View on Apple Maps
- WFD catchment
- Nent from Source to South Tyne (GB103023075420)
- 2024 spills / hours
- 109 / 1,723
- Long-term average
- 96.5 spills a year (monitored since 2024)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Monitor below 90%
- Comms failure / issue · Not Applicable - Ongoing investigation
- Investigation
- Env Act (SODRP) investigation ongoing, Operational investigation completed
- Improvement
- Operational improvement ongoing
- Volume & pollution
- Estimate from 986 hours spilling →
|
River Nent |
84 |
986 |
down 23% |
76% |
Bluehouse Gill CSO Overflow on sewer network
- EA ID / permit
- NWL00161 · 255/1075
- Outlet location
- NZ4628939473 (OS grid reference) · View on Apple Maps
- WFD catchment
- Blue House Gill (GB650301500002)
- Bathing water
- Crimdon
- 2024 spills / hours
- 97 / 1,035
- Long-term average
- 83.5 spills a year (monitored since 2018)
- High-spill reason (company)
- Performance - SW Infiltration
- Investigation
- Env Act (SODRP) investigation ongoing, Operational investigation completed
- Improvement
- No improvement action in reporting period
- Volume & pollution
- Estimate from 931 hours spilling →
|
Bluehouse Gill (North Sea) |
104 |
931 |
up 7% |
100% |
Blyth No. 5 SPS Storm discharge at pumping station
- EA ID / permit
- NWL00164 · 226/1176
- Outlet location
- NZ3157981847 (OS grid reference) · View on Apple Maps
- WFD catchment
- BLYTH (N) (GB510302203200)
- 2024 spills / hours
- 118 / 1,612
- Long-term average
- 80.5 spills a year (monitored since 2020)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- Operational investigation completed
- Improvement
- Operational improvement ongoing
- Volume & pollution
- Estimate from 917 hours spilling →
|
River Blyth (Saline Estuary) |
81 |
917 |
down 31% |
100% |
Great Broughton STW Storm tank at sewage works
- Sewage works
- Great Broughton
- EA ID / permit
- NWL00615 · 25/04/1676
- Outlet location
- NZ5412007120 (OS grid reference) · View on Apple Maps
- WFD catchment
- Broughton Beck from Source to River Leven (GB103025071870)
- 2024 spills / hours
- 74 / 702
- Long-term average
- 86.5 spills a year (monitored since 2020)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- Env Act (SODRP) investigation ongoing, Operational investigation completed
- Improvement
- No improvement action in reporting period
- Volume & pollution
- Estimate from 845 hours spilling →
|
Broughton Beck |
56 |
845 |
down 24% |
100% |
Howdon STW Inlet overflow at sewage works
- Sewage works
- Howdon
- EA ID / permit
- NWL00713 · 235/1695
- Outlet location
- NZ3370066130 (OS grid reference) · View on Apple Maps
- WFD catchment
- TYNE (GB510302310200)
- 2024 spills / hours
- 160 / 1,379
- Long-term average
- 136.2 spills a year (monitored since 2020)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- Env Act (SODRP) investigation ongoing
- Improvement
- No improvement action in reporting period
- Volume & pollution
- Estimate from 795 hours spilling →
|
River Tyne Saline Estuary |
113 |
795 |
down 29% |
100% |
Cargo Fleet SPS Storm discharge at pumping station
- EA ID / permit
- NWL00246 · 254/1514
- Outlet location
- NZ5145020480 (OS grid reference) · View on Apple Maps
- WFD catchment
- TEES (GB510302509900)
- 2024 spills / hours
- 83 / 866
- Long-term average
- 67.7 spills a year (monitored since 2020)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- Env Act (SODRP) investigation ongoing, Operational investigation ongoing
- Improvement
- Operational improvement ongoing
- Volume & pollution
- Estimate from 783 hours spilling →
|
Ormsby Beck |
81 |
783 |
down 2% |
100% |
Hadston Sewage Pumping Station Storm discharge at pumping station
- EA ID / permit
- NWL00635 · 224/0990
- Outlet location
- NZ2756999143 (OS grid reference) · View on Apple Maps
- WFD catchment
- Northumberland South (GB650301500001)
- Bathing water
- Druridge Bay North
- 2024 spills / hours
- 66 / 1,090
- Long-term average
- 54.6 spills a year (monitored since 2018)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- Operational investigation ongoing
- Improvement
- Operational improvement ongoing
- Volume & pollution
- Estimate from 757 hours spilling →
|
North Sea/Lady Burn |
50 |
757 |
down 24% |
100% |
Middleton-in-Teesdale STW Storm tank at sewage works
- Sewage works
- Middleton In Teesdale
- EA ID / permit
- NWL00878 · 25/01/0919
- Outlet location
- NY9526224911 (OS grid reference) · View on Apple Maps
- WFD catchment
- Tees from Maize Beck to Percy Beck (GB103025072511)
- 2024 spills / hours
- 129 / 1,710
- Long-term average
- 113.7 spills a year (monitored since 2021)
- High-spill reason (company)
- Performance - SW Infiltration
- Investigation
- Operational investigation completed
- Improvement
- Operational improvement ongoing
- Volume & pollution
- Estimate from 753 hours spilling →
|
River Tees |
70 |
753 |
down 46% |
99% |
Longhorsley STW Storm tank at sewage works
- Sewage works
- Longhorsley
- EA ID / permit
- NWL00810 · 223/0633
- Outlet location
- NZ1551694375 (OS grid reference) · View on Apple Maps
- WFD catchment
- Longdike Burn Catchment (trib of Coquet) (GB103022076550)
- 2024 spills / hours
- 78 / 1,347
- Long-term average
- 49.3 spills a year (monitored since 2020)
- High-spill reason (company)
- Performance - SW Infiltration
- Investigation
- Env Act (SODRP) investigation ongoing, Operational investigation completed
- Improvement
- Operational improvement ongoing
- Volume & pollution
- Estimate from 726 hours spilling →
|
Paxtondean Burn |
39 |
726 |
down 50% |
100% |
Newfield STW Storm tank at sewage works
- Sewage works
- Newfield
- EA ID / permit
- NWL00949 · 243/1015
- Outlet location
- NZ2004233525 (OS grid reference) · View on Apple Maps
- WFD catchment
- Wear from Gaunless to Browney (GB103024077464)
- 2024 spills / hours
- 115 / 1,049
- Long-term average
- 77.2 spills a year (monitored since 2021)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- Env Act (SODRP) investigation ongoing, Operational investigation completed
- Improvement
- Operational improvement ongoing
- Volume & pollution
- Estimate from 698 hours spilling →
|
River Wear |
96 |
698 |
down 17% |
100% |
Low Wadsworth STW Storm tank at sewage works
- Sewage works
- Low Wadsworth
- EA ID / permit
- NWL00819 · 241/1097
- Outlet location
- NZ1811430817 (OS grid reference) · View on Apple Maps
- WFD catchment
- Wear from Houselop Beck to Beechburn Beck (GB103024077462)
- 2024 spills / hours
- 119 / 2,048
- Long-term average
- 102.0 spills a year (monitored since 2020)
- High-spill reason (company)
- Performance - SW Infiltration
- Investigation
- Operational investigation ongoing
- Improvement
- Operational improvement ongoing
- Volume & pollution
- Estimate from 680 hours spilling →
|
River Wear |
62 |
680 |
down 48% |
98% |
Tilery Farm Strage Tank CSO Overflow on sewer network
- EA ID / permit
- NWL01385 · 255/1185
- Outlet location
- NZ4088536801 (OS grid reference) · View on Apple Maps
- WFD catchment
- Crimdon Beck from Source to Sea (GB103025075910)
- 2024 spills / hours
- 51 / 492
- Long-term average
- 58.9 spills a year (monitored since 2013)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- Env Act (SODRP) investigation ongoing
- Improvement
- No improvement action in reporting period
- Volume & pollution
- Estimate from 649 hours spilling →
|
Heads Hope Burn |
63 |
649 |
up 24% |
98% |
Aldbrough SPS Storm discharge at pumping station
- EA ID / permit
- NWL00032 · 25/02/1081
- Outlet location
- NZ2058611052 (OS grid reference) · View on Apple Maps
- WFD catchment
- Aldbrough Beck from Forcett Park Catch to Clow Bk (GB103025072060)
- 2024 spills / hours
- 87 / 1,573
- Long-term average
- 64.8 spills a year (monitored since 2020)
- High-spill reason (company)
- Performance - SW Infiltration
- Investigation
- Env Act (SODRP) investigation ongoing, Operational investigation completed
- Improvement
- Operational improvement ongoing
- Volume & pollution
- Estimate from 649 hours spilling →
|
Aldbrough Beck |
47 |
649 |
down 46% |
100% |
Powburn Sewage Treatment Works Storm tank at sewage works
- Sewage works
- Powburn
- EA ID / permit
- NWL01054 · 210/1295
- Outlet location
- NU0620416547 (OS grid reference) · View on Apple Maps
- WFD catchment
- Till from Linhope Burn to Roddam Burn (GB102021073041)
- 2024 spills / hours
- 104 / 1,336
- Long-term average
- 82.3 spills a year (monitored since 2020)
- High-spill reason (company)
- Not Applicable - Ongoing investigation
- Investigation
- Env Act (SODRP) investigation ongoing, Operational investigation ongoing
- Improvement
- No improvement action in reporting period
- Volume & pollution
- Estimate from 648 hours spilling →
|
The Pow Burn (River Till) |
38 |
648 |
down 63% |
99% |
Low Wadsworth PS Storm discharge at pumping station
- EA ID / permit
- NWL00818 · 241/1081
- Outlet location
- NZ1760030870 (OS grid reference) · View on Apple Maps
- WFD catchment
- Wear from Houselop Beck to Beechburn Beck (GB103024077462)
- 2024 spills / hours
- 64 / 993
- Long-term average
- 52.4 spills a year (monitored since 2013)
- High-spill reason (company)
- Performance - SW Infiltration
- Investigation
- Operational investigation ongoing
- Improvement
- Operational improvement ongoing
- Volume & pollution
- Estimate from 645 hours spilling →
|
River Wear |
52 |
645 |
down 19% |
100% |
Scots Gap STW Storm tank at sewage works
- Sewage works
- Scots Gap
- EA ID / permit
- NWL01146 · 225/A/0870
- Outlet location
- NZ0419886103 (OS grid reference) · View on Apple Maps
- WFD catchment
- Wansbeck from Ray Burn to Hart Burn (GB103022076990)
- 2024 spills / hours
- 102 / 1,275
- Long-term average
- 99.0 spills a year (monitored since 2021)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- Env Act (SODRP) investigation ongoing, Operational investigation ongoing
- Improvement
- No improvement action in reporting period
- Volume & pollution
- Estimate from 615 hours spilling →
|
Trib of Middleton Burn |
66 |
615 |
down 35% |
99% |
Byers Green SPS Storm discharge at pumping station
- EA ID / permit
- NWL00234 · 243/0959
- Outlet location
- NZ2199334709 (OS grid reference) · View on Apple Maps
- WFD catchment
- Wear from Gaunless to Browney (GB103024077464)
- 2024 spills / hours
- 66 / 754
- Long-term average
- 48.8 spills a year (monitored since 2020)
- High-spill reason (company)
- Performance - SW Infiltration
- Investigation
- Operational investigation ongoing
- Improvement
- Operational improvement ongoing
- Volume & pollution
- Estimate from 600 hours spilling →
|
River Wear |
53 |
600 |
down 20% |
100% |
Esh Winning Sewage Treatment Works Storm tank at sewage works
- Sewage works
- Esh Winning
- EA ID / permit
- NWL00524 · 244/1026
- Outlet location
- NZ2006942196 (OS grid reference) · View on Apple Maps
- WFD catchment
- Hedleyhope Burn from Source to Deerness (GB103024077290)
- 2024 spills / hours
- 113 / 1,467
- Long-term average
- 87.7 spills a year (monitored since 2021)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- Env Act (SODRP) investigation ongoing
- Improvement
- No improvement action in reporting period
- Volume & pollution
- Estimate from 600 hours spilling →
|
Priest Burn |
47 |
600 |
down 58% |
100% |
Rookhope STW Inlet overflow at sewage works
- Sewage works
- Rookhope
- EA ID / permit
- NWL01121 · 241/1145
- Outlet location
- NY9429041827 (OS grid reference) · View on Apple Maps
- WFD catchment
- Rookhope Burn from Source to Wear (GB103024077530)
- 2024 spills / hours
- 118 / 1,370
- Long-term average
- 94.5 spills a year (monitored since 2020)
- High-spill reason (company)
- Performance - SW Infiltration
- Investigation
- Env Act (SODRP) investigation ongoing, Operational investigation ongoing
- Improvement
- Operational improvement completed
- Volume & pollution
- Estimate from 596 hours spilling →
|
Rookhope Burn |
59 |
596 |
down 50% |
100% |
Moorsholm Sewage Treatment Works Inlet overflow at sewage works
- Sewage works
- Moorsholm
- EA ID / permit
- NWL00903 · 25/06/1010
- Outlet location
- NZ6904015580 (OS grid reference) · View on Apple Maps
- WFD catchment
- Kilton Beck from Source to Middle Gill Beck (GB103025071920)
- 2024 spills / hours
- 127 / 719
- Long-term average
- 94.2 spills a year (monitored since 2020)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- Operational investigation ongoing
- Improvement
- Operational improvement ongoing
- Volume & pollution
- Estimate from 587 hours spilling →
|
Hagg Beck (Kilton Beck Trib) |
113 |
587 |
down 11% |
99% |
Cattle Market B CSO Overflow on sewer network
- EA ID / permit
- NWL00260 · 242/1045
- Outlet location
- NZ2143428999 (OS grid reference) · View on Apple Maps
- WFD catchment
- Gaunless from Hummer Beck to Wear (GB103024072730)
- 2024 spills / hours
- 97 / 1,086
- Long-term average
- 77.8 spills a year (monitored since 2013)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- Env Act (SODRP) investigation ongoing, Operational investigation ongoing
- Improvement
- No improvement action in reporting period
- Volume & pollution
- Estimate from 582 hours spilling →
|
River Gaunless |
78 |
582 |
down 20% |
98% |
Middleton Airport Storm Tw Storm discharge at pumping station
- EA ID / permit
- NWL00875 · EPRPB3193VX
- Outlet location
- NZ3539911878 (OS grid reference) · View on Apple Maps
- WFD catchment
- Tees from Skerne to Tidal Limit (GB103025072595)
- 2024 spills / hours
- 39 / 613
- Long-term average
- 54.0 spills a year (monitored since 2020)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- Operational investigation completed
- Improvement
- Operational improvement ongoing
- Volume & pollution
- Estimate from 580 hours spilling →
|
River Tees |
42 |
580 |
up 8% |
98% |
Tyne View Terrace PS Storm discharge at pumping station
- EA ID / permit
- NWL01417 · 235/1690
- Outlet location
- NZ3328666098 (OS grid reference) · View on Apple Maps
- WFD catchment
- TYNE (GB510302310200)
- 2024 spills / hours
- 86 / 866
- Long-term average
- 73.3 spills a year (monitored since 2020)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- Operational investigation ongoing
- Improvement
- No improvement action in reporting period
- Volume & pollution
- Estimate from 573 hours spilling →
|
River Tyne |
65 |
573 |
down 24% |
100% |
Fir Tree STW Storm tank at sewage works
- Sewage works
- Fir Tree
- EA ID / permit
- NWL00555 · 241/1013
- Outlet location
- NZ1368934172 (OS grid reference) · View on Apple Maps
- WFD catchment
- Wear from Houselop Beck to Beechburn Beck (GB103024077462)
- 2024 spills / hours
- 108 / 939
- Long-term average
- 78.0 spills a year (monitored since 2020)
- High-spill reason (company)
- Performance - SW Infiltration
- Investigation
- Operational investigation completed
- Improvement
- No improvement action in reporting period
- Volume & pollution
- Estimate from 556 hours spilling →
|
Wadley Burn |
56 |
556 |
down 48% |
98% |
Limekiln Gill Pumping Station Storm discharge at pumping station
- EA ID / permit
- NWL00793 · 255/1114
- Outlet location
- NZ4776138312 (OS grid reference) · View on Apple Maps
- WFD catchment
- Tyne and Wear (GB650301500002)
- Bathing water
- Crimdon
- 2024 spills / hours
- 3 / 27
- Long-term average
- 17.0 spills a year (monitored since 2021)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- No investigation activity in reporting period
- Improvement
- No improvement action in reporting period
- Volume & pollution
- Estimate from 544 hours spilling →
|
North Sea |
32 |
544 |
up 967% |
100% |
Stannington Village SPS Storm discharge at pumping station
- EA ID / permit
- NWL01282 · 226/1000
- Outlet location
- NZ2132678967 (OS grid reference) · View on Apple Maps
- WFD catchment
- Blyth from Pont to Tidal Limit (GB103022077052)
- 2024 spills / hours
- 81 / 1,358
- Long-term average
- 57.0 spills a year (monitored since 2020)
- High-spill reason (company)
- Performance - SW Infiltration
- Investigation
- Env Act (SODRP) investigation ongoing, Operational investigation ongoing
- Improvement
- Operational improvement ongoing
- Volume & pollution
- Estimate from 542 hours spilling →
|
Catraw Burn (Blyth) |
32 |
542 |
down 60% |
100% |
Great Ayton Sewage Treatment Works Storm tank at sewage works
- Sewage works
- Great Ayton
- EA ID / permit
- NWL00613 · 25/04/1859
- Outlet location
- NZ5469309700 (OS grid reference) · View on Apple Maps
- WFD catchment
- Leven from Source to Tame (GB103025071890)
- 2024 spills / hours
- 67 / 718
- Long-term average
- 64.0 spills a year (monitored since 2020)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- No investigation activity in reporting period
- Improvement
- Operational improvement completed
- Volume & pollution
- Estimate from 533 hours spilling →
|
River Leven |
50 |
533 |
down 25% |
100% |
Marske Sewage Treatment Works Inlet overflow at sewage works
- Sewage works
- Marske
- EA ID / permit
- NWL00856 · 25/06/1015
- Outlet location
- NZ6405024200 (OS grid reference) · View on Apple Maps
- WFD catchment
- Tees Coastal (GB650301500005)
- Bathing water
- Marske Sands
- 2024 spills / hours
- 107 / 784
- Long-term average
- 99.6 spills a year (monitored since 2021)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- Operational investigation ongoing
- Improvement
- Operational improvement ongoing
- Volume & pollution
- Estimate from 531 hours spilling →
|
North Sea |
75 |
531 |
down 30% |
100% |
Sedgeletch STW Storm tank at sewage works
- Sewage works
- Sedgeletch
- EA ID / permit
- NWL01176 · 245/1243
- Outlet location
- NZ3202550822 (OS grid reference) · View on Apple Maps
- WFD catchment
- Lumley Park Burn from Source to Herrington Burn (GB103024077580)
- 2024 spills / hours
- 64 / 738
- Long-term average
- 43.8 spills a year (monitored since 2020)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- Env Act (SODRP) investigation ongoing, Operational investigation completed
- Improvement
- No improvement action in reporting period
- Volume & pollution
- Estimate from 526 hours spilling →
|
Herrington Burn/Moors Burn |
44 |
526 |
down 31% |
92% |
Amble Sewage Treatment Works Inlet overflow at sewage works
- Sewage works
- Amble
- EA ID / permit
- NWL00049 · 223/0931
- Outlet location
- NU2767004990 (OS grid reference) · View on Apple Maps
- WFD catchment
- Northumberland South (GB650301500001)
- 2024 spills / hours
- 124 / 626
- Long-term average
- 127.0 spills a year (monitored since 2021)
- High-spill reason (company)
- Not Applicable - Ongoing investigation
- Investigation
- Operational investigation ongoing
- Improvement
- No improvement action in reporting period
- Volume & pollution
- Estimate from 522 hours spilling →
|
North Sea |
91 |
522 |
down 27% |
100% |
Edmondsley STW Storm tank at sewage works
- Sewage works
- Edmondsley
- EA ID / permit
- NWL00498 · 245/0839
- Outlet location
- NZ2375950175 (OS grid reference) · View on Apple Maps
- WFD catchment
- Cong Burn from Source to Twizell Burn (GB103024077560)
- 2024 spills / hours
- 61 / 700
- Long-term average
- 54.8 spills a year (monitored since 2020)
- High-spill reason (company)
- Performance - SW Infiltration
- Investigation
- Env Act (SODRP) investigation ongoing
- Improvement
- No improvement action in reporting period
- Volume & pollution
- Estimate from 520 hours spilling →
|
Little Burn, Trib of Cong Burn |
45 |
520 |
down 26% |
100% |
Frosterley Sewage Treatment Works Inlet overflow at sewage works
- Sewage works
- Frosterley
- EA ID / permit
- NWL00576 · 241/1104
- Outlet location
- NZ0442036871 (OS grid reference) · View on Apple Maps
- WFD catchment
- Wear from Middlehope Burn to Houselop Beck (GB103024077461)
- 2024 spills / hours
- 71 / 244
- Long-term average
- 70.6 spills a year (monitored since 2020)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- Env Act (SODRP) investigation ongoing, Operational investigation ongoing
- Improvement
- No improvement action in reporting period
- Volume & pollution
- Estimate from 513 hours spilling →
|
Wear |
52 |
513 |
down 27% |
99% |
Eland Lane (New) Pumping Station Storm discharge at pumping station
- EA ID / permit
- NWL00504 · 226/A/0965
- Outlet location
- NZ1662472984 (OS grid reference) · View on Apple Maps
- WFD catchment
- Pont from Med Burn to Small Burn (GB103022076860)
- 2024 spills / hours
- 99 / 1,331
- Long-term average
- 77.2 spills a year (monitored since 2020)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- Env Act (SODRP) investigation ongoing, Operational investigation completed
- Improvement
- Operational improvement ongoing
- Volume & pollution
- Estimate from 510 hours spilling →
|
Pont |
47 |
510 |
down 53% |
100% |
East Tanfield STW Storm tank at sewage works
- Sewage works
- East Tanfield
- EA ID / permit
- NWL00488 · 235/1871
- Outlet location
- NZ1973655324 (OS grid reference) · View on Apple Maps
- WFD catchment
- Team from Source to Tyne (GB103023075670)
- 2024 spills / hours
- 86 / 856
- Long-term average
- 82.7 spills a year (monitored since 2020)
- High-spill reason (company)
- Performance - SW Infiltration
- Investigation
- Env Act (SODRP) investigation ongoing, Operational investigation ongoing
- Improvement
- Operational improvement ongoing
- Volume & pollution
- Estimate from 497 hours spilling →
|
Causey Burn |
51 |
497 |
down 41% |
100% |
Tyneside CSO (No B5/301) Overflow on sewer network
- EA ID / permit
- NWL01418 · 235/B/0169
- Outlet location
- NZ3348164722 (OS grid reference) · View on Apple Maps
- WFD catchment
- Don from Source to Tidal Limit (GB103023075690)
- 2024 spills / hours
- 111 / 933
- Long-term average
- 117.1 spills a year (monitored since 2018)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- Env Act (SODRP) investigation ongoing, Operational investigation ongoing
- Improvement
- Operational improvement ongoing
- Volume & pollution
- Estimate from 491 hours spilling →
|
Don |
121 |
491 |
up 9% |
100% |
Colwell STW Inlet overflow at sewage works
- Sewage works
- Colwell
- EA ID / permit
- NWL00309 · 231/1077
- Outlet location
- NY9538575002 (OS grid reference) · View on Apple Maps
- WFD catchment
- Barrasford Burn Catchment (trib of N Tyne) (GB103023074890)
- 2024 spills / hours
- 131 / 2,590
- Long-term average
- 125.2 spills a year (monitored since 2021)
- High-spill reason (company)
- Performance - SW Infiltration
- Investigation
- Env Act (SODRP) investigation ongoing, Operational investigation ongoing
- Improvement
- No improvement action in reporting period
- Volume & pollution
- Estimate from 486 hours spilling →
|
Coal Burn |
69 |
486 |
down 47% |
94% |
Newbiggin Sewage Treatment Works Inlet overflow at sewage works
- Sewage works
- Newbiggin
- EA ID / permit
- NWL00940 · 225/1031
- Outlet location
- NZ3238286215&NZ3129786715 (OS grid reference) · View on Apple Maps
- WFD catchment
- Tyne and Wear (GB650301500002)
- Bathing water
- Newbiggin North; Newbiggin South
- 2024 spills / hours
- 88 / 624
- Long-term average
- 63.9 spills a year (monitored since 2018)
- High-spill reason (company)
- Not asset maintenance - Hydraulic capacity
- Investigation
- Operational investigation completed
- Improvement
- No improvement action in reporting period
- Volume & pollution
- Estimate from 479 hours spilling →
|
North Sea |
78 |
479 |
down 11% |
100% |