Storm overflow register · Northumbrian Water

Milfield sewage works: storm overflow spills 2025

Milfield sewage treatment works, run by Northumbrian Water, has 1 monitored storm overflow discharging to Unnamed Trib River Till. In 2025 it recorded 83 spills totalling 1,193 hours, against 261 spills and 5,365 hours in 2024. By hours spilling, it ranks 10 of 183 Northumbrian Water works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecMilfield Sewage…3 spills, 60.5 h, 1 Jan to 3 Jan11 spills, 247 h, 4 Jan to 16 Jan14 spills, 390.5 h, 18 Jan to 7 Feb8 Feb 2025 08:59 GMT, 31.3 h11 Feb 2025 00:59 GMT, 32.5 h5 spills, 20.3 h, 16 Feb to 17 Feb5 spills, 17.5 h, 23 Feb to 24 Feb2 spills, 3.3 h, 26 Feb to 26 Feb3 spills, 216.5 h, 28 Feb to 10 Mar22 Mar 2025 20:39 GMT, 4.8 h153 spills, 39.7 h, 1 Apr to 3 Apr2 spills, 2.4 h, 11 Apr to 11 Apr5 spills, 94.3 h, 12 Apr to 16 Apr24 May 2025 00:49 GMT, 5.8 h25 May 2025 03:29 GMT, 70 min26 May 2025 22:29 GMT, 3.9 h7 Jun 2025 15:09 GMT, 6.2 h7 spills, 2.2 h, 10 Jun to 10 Jun21 Jun 2025 23:18 GMT, 114 min3 spills, 1 h, 19 Jul to 19 Jul3 spills, 1.5 h, 3 Sep to 3 Sep2 spills, 0.1 h, 20 Sep to 20 Sep19 Nov 2025 04:20 GMT, 18 min4 spills, 3 h, 24 Nov to 24 Nov2 spills, 1.6 h, 29 Nov to 29 Nov1 Dec 2025 19:20 GMT, 24 min5 Dec 2025 21:00 GMT, 24 min2 spills, 2.3 h, 7 Dec to 7 Dec9 Dec 2025 12:20 GMT, 24 min

Hours spilling by month, 2025

0200400600Jan 2025: 552 hours spillingJanFeb 2025: 253 hours spillingFebMar 2025: 220 hours spillingMarApr 2025: 136 hours spillingAprMay 2025: 11 hours spillingMayJun 2025: 10 hours spillingJunJul 2025: 1.0 hours spillingJulAug 2025: 0.0 hours spillingAugSep 2025: 1.6 hours spillingSepOct 2025: 0.0 hours spillingOctNov 2025: 4.8 hours spillingNovDec 2025: 3.5 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
5 Mar 2025, 19:29Milfield Sewage Treatment Works4.7 days
13 Apr 2025, 07:55Milfield Sewage Treatment Works3.2 days
4 Feb 2025, 09:14Milfield Sewage Treatment Works3.1 days
24 Jan 2025, 20:44Milfield Sewage Treatment Works2.7 days
10 Jan 2025, 20:44Milfield Sewage Treatment Works2.6 days

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate20,433 m³range 8,139 - 51,297 m³
In litres20.4 millionrange 8.1 million - 51.3 million L
Olympic swimming pools8.2at 2,500 m³ each
Organic load, as people's raw sewage30,649person-days of untreated BOD

Assumed spill rate while spilling: 1.9 - 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 326 kg1,839 kg10,259 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 855 kg8,684 kg36,985 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 15 kg129 kg477 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3-9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 9.8 kg53 kg277 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 813.9 billion organisms20.4 trillion organisms513.0 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Milfield Sewage Treatment Works

Storm tank at sewage works · discharges to Unnamed Trib River Till

Spills 2025
83 (1,193 hours) · down 68% on 2024
Spills 2024
261 (5,365 hours)
Long-term average
172.0 spills a year (monitored since 2024)
Monitor uptime
99% of the year
High-spill reason (company)
Performance - SW Infiltration
Investigation
Operational investigation completed
Improvement
No improvement action in reporting period
WFD catchment
Till from Glen to River Tweed (GB102021073050)
Outlet location
NT9388034340 (OS grid reference) · View on Apple Maps
EA ID / permit
NWL00881 · 210/1327

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024-25 [EA]. Infiltration of groundwater into sewers is taken as 0-40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies - environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 - per capita consumption
  3. HBF: Foul sewer design - historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 - CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Northumbrian Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.