Storm overflow register · Northumbrian Water

Newfield sewage works: storm overflow spills 2025

Newfield sewage treatment works, run by Northumbrian Water, has 1 monitored storm overflow discharging to River Wear. In 2025 it recorded 96 spills totalling 698 hours, against 115 spills and 1,049 hours in 2024. By hours spilling, it ranks 19 of 183 Northumbrian Water works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecNewfield STW1 Jan 2025 00:00 GMT, 22.1 h3 spills, 74.3 h, 5 Jan to 8 Jan5 spills, 7.5 h, 24 Jan to 24 Jan3 spills, 52.9 h, 26 Jan to 28 Jan7 spills, 6.1 h, 10 Feb to 11 Feb3 spills, 2.8 h, 19 Feb to 20 Feb2 spills, 1.3 h, 21 Feb to 21 Feb3 spills, 1.7 h, 24 Feb to 24 Feb7 Mar 2025 11:05 GMT, 37 min12 Mar 2025 19:24 GMT, 22 min2 spills, 4.5 h, 22 Mar to 23 Mar1 May 2025 17:24 GMT, 29 min2 spills, 3.1 h, 23 May to 24 May2 spills, 0.9 h, 27 May to 27 May29 May 2025 02:35 GMT, 71 min3 Jun 2025 06:03 GMT, 30 min2 spills, 0.7 h, 4 Jun to 5 Jun3 spills, 1.9 h, 7 Jun to 7 Jun21 Jun 2025 19:58 GMT, 24 min22 Jun 2025 21:27 GMT, 27 min24 Jun 2025 17:16 GMT, 11 min2 spills, 0.4 h, 26 Jun to 26 Jun4 spills, 1.7 h, 2 Jul to 2 Jul7 Jul 2025 20:34 GMT, 36 min8 Jul 2025 17:11 GMT, 54 min14 Jul 2025 13:46 GMT, 26 min3 spills, 4.7 h, 15 Jul to 15 Jul4 spills, 7.7 h, 19 Jul to 19 Jul20 Jul 2025 16:10 GMT, 20 min3 Aug 2025 08:42 GMT, 22 min2 spills, 1.5 h, 4 Aug to 4 Aug2 spills, 0.8 h, 11 Aug to 11 Aug27 Aug 2025 16:24 GMT, 36 min1 Sep 2025 12:38 GMT, 52 min2 spills, 1.1 h, 3 Sep to 3 Sep4 spills, 3.2 h, 10 Sep to 11 Sep3 spills, 1.1 h, 13 Sep to 13 Sep2 spills, 1.5 h, 14 Sep to 15 Sep17 Sep 2025 04:33 GMT, 51 min5 spills, 17.6 h, 20 Sep to 21 Sep2 spills, 3.1 h, 1 Oct to 1 Oct3 spills, 10 h, 2 Oct to 3 Oct2 spills, 10.8 h, 19 Oct to 20 Oct21 Oct 2025 08:40 GMT, 20 min24 Oct 2025 23:57 GMT, 32 min3 spills, 3.3 h, 4 Nov to 5 Nov9 Nov 2025 18:14 GMT, 22 min3 spills, 7.7 h, 10 Nov to 11 Nov2 spills, 71.8 h, 12 Nov to 15 Nov2 spills, 25.9 h, 18 Nov to 19 Nov23 Nov 2025 06:42 GMT, 68 min2 spills, 18.9 h, 24 Nov to 25 Nov26 Nov 2025 15:39 GMT, 2.6 h28 Nov 2025 11:40 GMT, 2.2 h8 spills, 75.2 h, 29 Nov to 2 Dec8 spills, 116.8 h, 5 Dec to 11 Dec9 spills, 95.5 h, 15 Dec to 19 Dec5 spills, 21.3 h, 21 Dec to 22 Dec

Hours spilling by month, 2025

0100200300Jan 2025: 157 hours spillingJanFeb 2025: 12 hours spillingFebMar 2025: 5.5 hours spillingMarApr 2025: 0.0 hours spillingAprMay 2025: 5.6 hours spillingMayJun 2025: 4.5 hours spillingJunJul 2025: 16 hours spillingJulAug 2025: 3.3 hours spillingAugSep 2025: 26 hours spillingSepOct 2025: 25 hours spillingOctNov 2025: 165 hours spillingNovDec 2025: 278 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
5 Jan 2025, 13:59Newfield STW3.0 days
12 Nov 2025, 19:49Newfield STW3.0 days
9 Dec 2025, 04:13Newfield STW2.3 days
17 Dec 2025, 17:38Newfield STW2.1 days
27 Jan 2025, 02:05Newfield STW1.8 days

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate11,955 m³range 4,762 - 30,013 m³
In litres12.0 millionrange 4.8 million - 30.0 million L
Olympic swimming pools4.8at 2,500 m³ each
Organic load, as people's raw sewage17,932person-days of untreated BOD

Assumed spill rate while spilling: 1.9 - 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 190 kg1,076 kg6,003 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 500 kg5,081 kg21,639 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 9.0 kg75 kg279 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3-9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 5.7 kg31 kg162 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 476.2 billion organisms12.0 trillion organisms300.1 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Newfield STW

Storm tank at sewage works · discharges to River Wear

Spills 2025
96 (698 hours) · down 17% on 2024
Spills 2024
115 (1,049 hours)
Long-term average
77.2 spills a year (monitored since 2021)
Monitor uptime
100% of the year
High-spill reason (company)
Not asset maintenance - Hydraulic capacity
Investigation
Env Act (SODRP) investigation ongoing, Operational investigation completed
Improvement
Operational improvement ongoing
WFD catchment
Wear from Gaunless to Browney (GB103024077464)
Outlet location
NZ2004233525 (OS grid reference) · View on Apple Maps
EA ID / permit
NWL00949 · 243/1015

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024-25 [EA]. Infiltration of groundwater into sewers is taken as 0-40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies - environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 - per capita consumption
  3. HBF: Foul sewer design - historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 - CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Northumbrian Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.