Storm overflow register · Severn Trent Water

Ashover sewage works: storm overflow spills 2025

Ashover sewage treatment works, run by Severn Trent Water, has 2 monitored storm overflows discharging to River Amber. In 2025 they recorded 152 spills totalling 1,781 hours, against 148 spills and 1,275 hours in 2024. By hours spilling, it ranks 5 of 435 Severn Trent Water works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecAshover STW5 spills, 37.1 h, 1 Jan to 2 Jan6 spills, 84.9 h, 5 Jan to 9 Jan13 Jan 2025 22:59 GMT, 58 min22 Jan 2025 06:00 GMT, 29 min4 spills, 27.7 h, 23 Jan to 25 Jan9 spills, 61.5 h, 26 Jan to 29 Jan31 Jan 2025 02:28 GMT, 2.2 h10 Feb 2025 08:16 GMT, 5 min20 Feb 2025 15:26 GMT, 49 min6 spills, 20 h, 23 Feb to 24 Feb26 Feb 2025 08:54 GMT, 4 min2 spills, 0.4 h, 11 Mar to 11 Mar4 spills, 3.5 h, 22 Mar to 22 Mar31 Mar 2025 11:15 GMT, 4 min16 Apr 2025 00:12 GMT, 21 min21 Apr 2025 11:17 GMT, 10 min24 May 2025 01:38 GMT, 29 min9 spills, 9.5 h, 26 May to 28 May2 spills, 0.6 h, 3 Jun to 3 Jun5 Jun 2025 08:36 GMT, 31 min22 Jun 2025 11:35 GMT, 15 min2 spills, 4 h, 6 Jul to 6 Jul15 Jul 2025 11:28 GMT, 46 min19 Jul 2025 13:07 GMT, 91 min5 spills, 5.6 h, 20 Jul to 20 Jul28 Aug 2025 12:39 GMT, 12 min29 Aug 2025 12:17 GMT, 19 min30 Aug 2025 17:51 GMT, 11 min1 Sep 2025 12:31 GMT, 27 min3 Sep 2025 13:29 GMT, 34 min2 spills, 4.5 h, 4 Sep to 4 Sep10 Sep 2025 18:56 GMT, 25 min13 Sep 2025 03:58 GMT, 17 min3 spills, 2.6 h, 14 Sep to 14 Sep4 spills, 7.3 h, 17 Sep to 17 Sep4 spills, 10.1 h, 20 Sep to 21 Sep28 Sep 2025 01:38 GMT, 50 min10 spills, 13.4 h, 2 Oct to 4 Oct3 spills, 9.9 h, 19 Oct to 20 Oct2 spills, 5 h, 22 Oct to 23 Oct26 Oct 2025 19:25 GMT, 25 min3 spills, 1.3 h, 31 Oct to 31 Oct3 spills, 1.4 h, 1 Nov to 1 Nov6 spills, 16.1 h, 4 Nov to 5 Nov7 Nov 2025 14:05 GMT, 55 min27 spills, 138.4 h, 9 Nov to 17 Nov17 spills, 35.1 h, 18 Nov to 20 Nov10 spills, 25.7 h, 22 Nov to 24 Nov25 Nov 2025 22:53 GMT, 10 h10 spills, 106.1 h, 28 Nov to 3 Dec18 spills, 100.2 h, 4 Dec to 11 Dec2 spills, 4.1 h, 12 Dec to 12 Dec19 spills, 151.7 h, 15 Dec to 22 DecAshover STW24 May 2025 01:08 GMT, 7 min2 spills, 0.1 h, 26 May to 26 May3 spills, 0.8 h, 28 May to 28 May3 spills, 1.3 h, 29 May to 29 May3 spills, 0.7 h, 30 May to 30 May5 Nov 2025 03:24 GMT, 7.1 h5 spills, 203 h, 10 Nov to 20 Nov23 Nov 2025 08:45 GMT, 39.2 h26 Nov 2025 01:39 GMT, 8.8 h8 spills, 608.9 h, 29 Nov to 25 Dec

Hours spilling by month, 2025

02505007501,000Jan 2025: 215 hours spillingJanFeb 2025: 21 hours spillingFebMar 2025: 4.0 hours spillingMarApr 2025: 0.5 hours spillingAprMay 2025: 13 hours spillingMayJun 2025: 1.3 hours spillingJunJul 2025: 12 hours spillingJulAug 2025: 0.7 hours spillingAugSep 2025: 27 hours spillingSepOct 2025: 30 hours spillingOctNov 2025: 587 hours spillingNovDec 2025: 870 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
4 Dec 2025, 08:26Ashover STW9.9 days
17 Dec 2025, 15:25Ashover STW7.0 days
29 Nov 2025, 01:31Ashover STW4.4 days
28 Nov 2025, 23:24Ashover STW4.1 days
14 Nov 2025, 04:50Ashover STW3.8 days

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate30,515 m³range 12,155 - 76,608 m³
In litres30.5 millionrange 12.2 million - 76.6 million L
Olympic swimming pools12at 2,500 m³ each
Organic load, as people's raw sewage45,772person-days of untreated BOD

Assumed spill rate while spilling: 1.9 - 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 486 kg2,746 kg15,322 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 1,276 kg12,969 kg55,235 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 23 kg192 kg712 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3-9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 15 kg79 kg414 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 1.2 trillion organisms30.5 trillion organisms766.1 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Ashover STW

Inlet overflow at sewage works · discharges to River Amber

Spills 2025
103 (911 hours) · down 30% on 2024
Spills 2024
148 (1,275 hours)
Long-term average
115.4 spills a year (monitored since 2021)
Monitor uptime
100% of the year
High-spill reason (company)
Not asset maintenance - Hydraulic capacity
Investigation
UWWTR investigation ongoing, Operational investigation completed
Improvement
Operational improvement completed
WFD catchment
Amber from Source to Press Brook (GB104028052380)
Outlet location
SK3461362880 (OS grid reference) · View on Apple Maps
EA ID / permit
SVT00130 · T/41/45611/R · company name: ASHOVER STW (CSO)

Ashover STW

Storm tank at sewage works · discharges to River Amber

Spills 2025
49 (870 hours) · up from 0 on 2024
Spills 2024
0 (0.0 hours)
Long-term average
54.5 spills a year (monitored since 2020)
Monitor uptime
99% of the year
High-spill reason (company)
Not asset maintenance - Hydraulic capacity
Investigation
UWWTR investigation ongoing, Operational investigation completed
Improvement
No improvement action in reporting period
WFD catchment
Amber from Source to Press Brook (GB104028052380)
Outlet location
SK3461362880 (OS grid reference) · View on Apple Maps
EA ID / permit
SVT00129 · T/41/45611/R · company name: ASHOVER STW (SSTO)

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024-25 [EA]. Infiltration of groundwater into sewers is taken as 0-40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies - environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 - per capita consumption
  3. HBF: Foul sewer design - historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 - CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Severn Trent Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.