Storm overflow register · Severn Trent Water

Barrow And Quorn sewage works: storm overflow spills 2025

Barrow And Quorn sewage treatment works, run by Severn Trent Water, has 1 monitored storm overflow discharging to Tributary of River Soar. In 2025 it recorded 35 spills totalling 445 hours, against 84 spills and 1,344 hours in 2024. By hours spilling, it ranks 95 of 435 Severn Trent Water works, where 1 spilled longest.

Works size: 12,186 population equivalent (BARROW & QUORN STW, UWWTD 2018). Used for the spill volume estimate.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecBarrow & Quorn STW5 Jan 2025 17:06 GMT, 154.2 h12 Jan 2025 03:41 GMT, 36 min12 Jan 2025 09:04 GMT, 16.2 h13 Jan 2025 08:00 GMT, 16.7 h14 Jan 2025 08:40 GMT, 3.3 h14 Jan 2025 19:23 GMT, 4.8 h28 Jan 2025 11:22 GMT, 12.2 h14 Sep 2025 19:18 GMT, 82 min14 Nov 2025 08:48 GMT, 41.2 h16 Nov 2025 02:29 GMT, 72 min16 Nov 2025 08:38 GMT, 13.6 h17 Nov 2025 08:26 GMT, 85 min17 Nov 2025 10:15 GMT, 16 min22 Nov 2025 16:50 GMT, 3.1 h23 Nov 2025 06:38 GMT, 8 h29 Nov 2025 09:58 GMT, 15.2 h30 Nov 2025 09:16 GMT, 5.7 h30 Nov 2025 18:55 GMT, 2.4 h1 Dec 2025 02:36 GMT, 67 min1 Dec 2025 07:06 GMT, 6.7 h1 Dec 2025 19:02 GMT, 4.4 h2 Dec 2025 08:12 GMT, 95 min2 Dec 2025 18:08 GMT, 3.3 h4 Dec 2025 11:42 GMT, 10.7 h5 Dec 2025 08:20 GMT, 2.1 h5 Dec 2025 18:06 GMT, 5.3 h6 Dec 2025 09:10 GMT, 5.2 h7 Dec 2025 10:36 GMT, 11 min7 Dec 2025 13:10 GMT, 7.6 h9 Dec 2025 03:26 GMT, 10.8 h9 Dec 2025 18:45 GMT, 2.8 h10 Dec 2025 08:15 GMT, 46 min10 Dec 2025 09:33 GMT, 2.4 h16 Dec 2025 08:38 GMT, 4.2 h18 Dec 2025 13:20 GMT, 60 h21 Dec 2025 09:44 GMT, 7 h21 Dec 2025 17:15 GMT, 8.2 h

Estimated spill volume by month, 2025

Hours spilling each month × the estimated spill rate for a works of this size. The bars are central estimates and the whiskers show the low–high range. Method.

050k100k150kJan 2025: 208 h spilling ≈ 43,410 m³ (range 17,291–108,981 m³)JanFeb 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)FebMar 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)MarApr 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)AprMay 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)MayJun 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)JunJul 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)JulAug 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)AugSep 2025: 1.4 h spilling ≈ 292 m³ (range 116–734 m³)SepOct 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)OctNov 2025: 92 h spilling ≈ 19,189 m³ (range 7,643–48,174 m³)NovDec 2025: 144 h spilling ≈ 30,046 m³ (range 11,968–75,433 m³)Dec
Cubic metres (m³), estimate. Hours are measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDurationEstimated volume
5 Jan 2025, 17:06Barrow & Quorn STW6.4 days12,826 – 80,841 m³
18 Dec 2025, 13:20Barrow & Quorn STW2.5 days4,986 – 31,426 m³
14 Nov 2025, 08:48Barrow & Quorn STW1.7 days3,428 – 21,606 m³
13 Jan 2025, 08:00Barrow & Quorn STW16.7 h1,385 – 8,728 m³
12 Jan 2025, 09:04Barrow & Quorn STW16.2 h1,349 – 8,501 m³

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

Volume, central estimate92,937 m³range 37,019 – 233,322 m³
In litres92.9 millionrange 37.0 million – 233.3 million L
Olympic swimming pools37at 2,500 m³ each
Organic load, as people's raw sewage139,405person-days of untreated BOD

Assumed spill rate while spilling: 23.1 – 145.6 L/s (central 58.0 L/s), from a dry-weather flow of 23.1 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 1,481 kg8,364 kg46,664 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 3,887 kg39,498 kg168,225 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 70 kg586 kg2,170 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3–9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 44 kg242 kg1,260 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 3.7 trillion organisms92.9 trillion organisms2.3 × 10¹⁵ organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Barrow & Quorn STW

Storm tank at sewage works · discharges to Tributary of River Soar

Spills 2025
35 (445 hours) · down 58% on 2024
Spills 2024
84 (1,344 hours)
Long-term average
61.0 spills a year (monitored since 2020)
Monitor uptime
99% of the year
High-spill reason (company)
Not asset maintenance - Hydraulic capacity
Investigation
Env Act (SODRP) investigation ongoing, UWWTR investigation ongoing, Operational investigation completed
Improvement
Operational improvement completed
WFD catchment
Soar from Rothley Brook to Long Whatton Brook (GB104028047211)
Outlet location
SK5597618163 (OS grid reference) · View on Apple Maps
EA ID / permit
SVT00186 · T/57/45505/R · company name: BARROW & QUORN (STW)

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024–25 [EA]. Infiltration of groundwater into sewers is taken as 0–40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies – environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 – per capita consumption
  3. HBF: Foul sewer design – historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 – CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Severn Trent Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.