Storm overflow register · Severn Trent Water

Himley sewage works: storm overflow spills 2025

Himley sewage treatment works, run by Severn Trent Water, has 1 monitored storm overflow discharging to Tributary of Smestow Brook. In 2025 it recorded 42 spills totalling 378 hours, against 25 spills and 135 hours in 2024. By hours spilling, it ranks 109 of 435 Severn Trent Water works, where 1 spilled longest.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecHimley STW26 Jan 2025 15:25 GMT, 50 min26 Jan 2025 23:48 GMT, 15 min23 Feb 2025 22:02 GMT, 12 min24 Feb 2025 10:38 GMT, 54 min23 Apr 2025 01:24 GMT, 2.2 h20 May 2025 09:09 GMT, 11 min21 May 2025 17:57 GMT, 36 h23 May 2025 17:07 GMT, 66.9 h26 May 2025 16:47 GMT, 13.2 h27 May 2025 11:48 GMT, 9.1 h5 Jun 2025 14:32 GMT, 5 min5 Jun 2025 14:46 GMT, 12.1 h3 Sep 2025 13:12 GMT, 54 min3 Sep 2025 15:47 GMT, 12.2 h4 Sep 2025 10:55 GMT, 18.3 h7 Sep 2025 11:37 GMT, 82 min14 Sep 2025 14:56 GMT, 39 min14 Sep 2025 15:46 GMT, 35 min19 Oct 2025 17:04 GMT, 13.7 h31 Oct 2025 00:36 GMT, 31.7 h1 Nov 2025 08:21 GMT, 41.5 h4 Nov 2025 18:04 GMT, 21.3 h10 Nov 2025 03:30 GMT, 13 min11 Nov 2025 21:08 GMT, 109 min12 Nov 2025 08:06 GMT, 31 min12 Nov 2025 13:14 GMT, 29 min14 Nov 2025 07:16 GMT, 10.2 h22 Nov 2025 09:07 GMT, 25 min29 Nov 2025 04:44 GMT, 2.3 h29 Nov 2025 08:04 GMT, 73 min4 Dec 2025 13:01 GMT, 8.3 h5 Dec 2025 19:19 GMT, 37.3 h7 Dec 2025 12:59 GMT, 8.5 h9 Dec 2025 07:31 GMT, 4.9 h10 Dec 2025 08:48 GMT, 31 min17 Dec 2025 23:24 GMT, 79 min18 Dec 2025 02:06 GMT, 8.8 h18 Dec 2025 13:43 GMT, 2.5 h18 Dec 2025 16:26 GMT, 4.7 h18 Dec 2025 21:10 GMT, 5 min

Hours spilling by month, 2025

050100150Jan 2025: 1.1 hours spillingJanFeb 2025: 1.1 hours spillingFebMar 2025: 0.0 hours spillingMarApr 2025: 2.2 hours spillingAprMay 2025: 125 hours spillingMayJun 2025: 12 hours spillingJunJul 2025: 0.0 hours spillingJulAug 2025: 0.0 hours spillingAugSep 2025: 34 hours spillingSepOct 2025: 37 hours spillingOctNov 2025: 88 hours spillingNovDec 2025: 77 hours spillingDec
Hours, measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDuration
23 May 2025, 17:07Himley STW2.8 days
1 Nov 2025, 08:21Himley STW1.7 days
5 Dec 2025, 19:19Himley STW1.6 days
21 May 2025, 17:57Himley STW1.5 days
31 Oct 2025, 00:36Himley STW1.3 days

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

This works serves fewer than 2,000 people, or was not matched to a UWWTD report, so its size is not published. The population equivalent above is a placeholder of 1,000. Enter the population served if you know it.

Volume, central estimate6,482 m³range 2,582 – 16,273 m³
In litres6.5 millionrange 2.6 million – 16.3 million L
Olympic swimming pools2.6at 2,500 m³ each
Organic load, as people's raw sewage9,723person-days of untreated BOD

Assumed spill rate while spilling: 1.9 – 11.9 L/s (central 4.8 L/s), from a dry-weather flow of 1.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 103 kg583 kg3,255 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 271 kg2,755 kg11,733 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 4.9 kg41 kg151 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3–9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 3.1 kg17 kg88 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 258.2 billion organisms6.5 trillion organisms162.7 trillion organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Himley STW

Inlet overflow at sewage works · discharges to Tributary of Smestow Brook

Spills 2025
42 (378 hours) · up 68% on 2024
Spills 2024
25 (135 hours)
Long-term average
63.5 spills a year (monitored since 2020)
Monitor uptime
99% of the year
High-spill reason (company)
Not asset maintenance - Hydraulic capacity
Investigation
UWWTR investigation ongoing, Operational investigation completed
Improvement
Operational improvement completed
WFD catchment
Bobs-Holbeche Bk - source to conf Smestow Bk (GB109054044830)
Outlet location
SO8766291029 (OS grid reference) · View on Apple Maps
EA ID / permit
SVT01144 · S/06/55931/R · company name: HIMLEY (STW)

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024–25 [EA]. Infiltration of groundwater into sewers is taken as 0–40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies – environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 – per capita consumption
  3. HBF: Foul sewer design – historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 – CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Severn Trent Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.