Storm overflow register · Severn Trent Water

Packington sewage works: storm overflow spills 2025

Packington sewage treatment works, run by Severn Trent Water, has 1 monitored storm overflow discharging to Gilwiskaw Brook. In 2025 it recorded 40 spills totalling 448 hours, against 69 spills and 901 hours in 2024. By hours spilling, it ranks 94 of 435 Severn Trent Water works, where 1 spilled longest.

Works size: 17,375 population equivalent (PACKINGTON STW, UWWTD 2018). Used for the spill volume estimate.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecPackington WwTW1 Jan 2025 14:15 GMT, 3.9 h1 Jan 2025 18:41 GMT, 20 min1 Jan 2025 21:44 GMT, 2.2 h5 Jan 2025 14:41 GMT, 60.2 h8 Jan 2025 06:55 GMT, 8.4 h8 Jan 2025 15:55 GMT, 24 min8 Jan 2025 17:55 GMT, 4.6 h27 Jan 2025 03:21 GMT, 10 h27 Jan 2025 14:53 GMT, 48 min24 Feb 2025 00:59 GMT, 111 min23 Apr 2025 05:51 GMT, 2.1 h27 May 2025 13:08 GMT, 4.2 h27 May 2025 18:05 GMT, 4.3 h7 Jul 2025 04:40 GMT, 101 min4 Sep 2025 12:21 GMT, 2.3 h14 Sep 2025 18:10 GMT, 4.9 h17 Sep 2025 09:55 GMT, 3.2 h3 Oct 2025 16:55 GMT, 2.7 h3 Oct 2025 21:20 GMT, 2.3 h19 Oct 2025 22:36 GMT, 73 min4 Nov 2025 21:07 GMT, 5.1 h10 Nov 2025 15:23 GMT, 9.9 h11 Nov 2025 07:10 GMT, 4.2 h11 Nov 2025 23:11 GMT, 25.1 h14 Nov 2025 07:40 GMT, 62.2 h22 Nov 2025 16:08 GMT, 8 h23 Nov 2025 07:08 GMT, 15.5 h23 Nov 2025 22:55 GMT, 41 min29 Nov 2025 08:44 GMT, 17.4 h1 Dec 2025 22:25 GMT, 3.5 h2 Dec 2025 02:04 GMT, 22 min9 Dec 2025 09:41 GMT, 18.1 h10 Dec 2025 09:21 GMT, 13.5 h10 Dec 2025 23:10 GMT, 10 min16 Dec 2025 00:47 GMT, 27.1 h17 Dec 2025 04:10 GMT, 20 min17 Dec 2025 08:51 GMT, 88.1 h21 Dec 2025 21:12 GMT, 27 h

Estimated spill volume by month, 2025

Hours spilling each month × the estimated spill rate for a works of this size. The bars are central estimates and the whiskers show the low–high range. Method.

050k100k150kJan 2025: 91 h spilling ≈ 27,032 m³ (range 10,767–67,865 m³)JanFeb 2025: 1.9 h spilling ≈ 566 m³ (range 225–1,420 m³)FebMar 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)MarApr 2025: 2.1 h spilling ≈ 625 m³ (range 249–1,570 m³)AprMay 2025: 8.5 h spilling ≈ 2,531 m³ (range 1,008–6,353 m³)MayJun 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)JunJul 2025: 1.7 h spilling ≈ 506 m³ (range 202–1,271 m³)JulAug 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0–0.0 m³)AugSep 2025: 10 h spilling ≈ 3,096 m³ (range 1,233–7,773 m³)SepOct 2025: 6.2 h spilling ≈ 1,846 m³ (range 735–4,634 m³)OctNov 2025: 148 h spilling ≈ 44,061 m³ (range 17,550–110,617 m³)NovDec 2025: 178 h spilling ≈ 52,993 m³ (range 21,108–133,040 m³)Dec
Cubic metres (m³), estimate. Hours are measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDurationEstimated volume
17 Dec 2025, 08:51Packington WwTW3.7 days10,445 – 65,835 m³
14 Nov 2025, 07:40Packington WwTW2.6 days7,378 – 46,502 m³
5 Jan 2025, 14:41Packington WwTW2.5 days7,135 – 44,969 m³
16 Dec 2025, 00:47Packington WwTW1.1 days3,208 – 20,218 m³
21 Dec 2025, 21:12Packington WwTW1.1 days3,196 – 20,143 m³

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

Volume, central estimate133,226 m³range 53,067 – 334,468 m³
In litres133.2 millionrange 53.1 million – 334.5 million L
Olympic swimming pools53at 2,500 m³ each
Organic load, as people's raw sewage199,838person-days of untreated BOD

Assumed spill rate while spilling: 32.9 – 207.6 L/s (central 82.7 L/s), from a dry-weather flow of 32.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 2,123 kg11,990 kg66,894 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 5,572 kg56,621 kg241,151 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 101 kg839 kg3,111 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3–9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 64 kg346 kg1,806 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 5.3 trillion organisms133.2 trillion organisms3.3 × 10¹⁵ organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Packington WwTW

Storm tank at sewage works · discharges to Gilwiskaw Brook

Spills 2025
40 (447 hours) · down 42% on 2024
Spills 2024
69 (901 hours)
Long-term average
52.0 spills a year (monitored since 2021)
Monitor uptime
100% of the year
High-spill reason (company)
Not asset maintenance - Hydraulic capacity
Investigation
Env Act (SODRP) investigation ongoing, UWWTR investigation completed, Operational investigation completed
Improvement
Operational improvement completed
WFD catchment
Gilwiskaw Brook from Source to River Mease (GB104028046590)
Outlet location
SK3598214071 (OS grid reference) · View on Apple Maps
EA ID / permit
SVT01747 · T/23/36076/R · company name: PACKINGTON STW (SSTO)

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024–25 [EA]. Infiltration of groundwater into sewers is taken as 0–40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies – environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 – per capita consumption
  3. HBF: Foul sewer design – historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 – CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Severn Trent Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.