Storm overflow register · Severn Trent Water

Stratford Milcote sewage works: storm overflow spills 2025

Stratford Milcote sewage treatment works, run by Severn Trent Water, has 1 monitored storm overflow discharging to River Avon. In 2025 it recorded 26 spills totalling 193 hours, against 36 spills and 489 hours in 2024. By hours spilling, it ranks 182 of 435 Severn Trent Water works, where 1 spilled longest.

Works size: 33,187 population equivalent (STRATFORD STW, UWWTD 2018). Used for the spill volume estimate.

Every spill in 2025

Each blue mark is one spill, placed by when it started and sized by how long it lasted. Hover over a mark for the date and duration.

JanFebMarAprMayJunJulAugSepOctNovDecStratford Milcote STW12 spills, 94.3 h, 5 Jan to 9 Jan48 spills, 34.5 h, 27 Jan to 29 Jan5 spills, 7.1 h, 24 Feb to 25 Feb5 spills, 2.3 h, 26 Feb to 26 Feb22 Mar 2025 22:22 GMT, 4.8 h4 spills, 1.5 h, 10 Nov to 10 Nov2 spills, 1.1 h, 13 Nov to 13 Nov21 spills, 8.1 h, 14 Nov to 14 Nov21 spills, 11.9 h, 16 Nov to 17 Nov2 spills, 0.5 h, 9 Dec to 10 Dec7 spills, 0.7 h, 16 Dec to 16 Dec7 spills, 1.6 h, 16 Dec to 18 Dec67 spills, 24.6 h, 20 Dec to 22 Dec

Estimated spill volume by month, 2025

Hours spilling each month × the estimated spill rate for a works of this size. The bars are central estimates and the whiskers show the low-high range. Method.

050k100k150k200kJan 2025: 129 h spilling ≈ 73,241 m³ (range 29,173-183,874 m³)JanFeb 2025: 9.4 h spilling ≈ 5,345 m³ (range 2,129-13,419 m³)FebMar 2025: 4.8 h spilling ≈ 2,729 m³ (range 1,087-6,852 m³)MarApr 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0-0.0 m³)AprMay 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0-0.0 m³)MayJun 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0-0.0 m³)JunJul 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0-0.0 m³)JulAug 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0-0.0 m³)AugSep 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0-0.0 m³)SepOct 2025: 0.0 h spilling ≈ 0.0 m³ (range 0.0-0.0 m³)OctNov 2025: 23 h spilling ≈ 12,794 m³ (range 5,096-32,121 m³)NovDec 2025: 27 h spilling ≈ 15,524 m³ (range 6,183-38,973 m³)Dec
Cubic metres (m³), estimate. Hours are measured by the event duration monitor.

Longest single spills

Started (GMT)OverflowDurationEstimated volume
5 Jan 2025, 21:38Stratford Milcote STW3.4 days18,305 - 115,373 m³
27 Jan 2025, 15:46Stratford Milcote STW8.0 h1,816 - 11,445 m³
9 Jan 2025, 06:32Stratford Milcote STW7.2 h1,619 - 10,207 m³
28 Jan 2025, 07:58Stratford Milcote STW6.2 h1,397 - 8,803 m³
16 Nov 2025, 17:13Stratford Milcote STW5.5 h1,253 - 7,899 m³

Estimated 2025 spill volume and pollution

Estimate, not a measurement. Monitors record how long an overflow spills, not how much. This calculator back-calculates a spill rate from the size of the works, using the Environment Agency's permit formulae, and multiplies it by published storm-sewage concentrations. How it works.

Volume, central estimate109,804 m³range 43,737 - 275,668 m³
In litres109.8 millionrange 43.7 million - 275.7 million L
Olympic swimming pools44at 2,500 m³ each
Organic load, as people's raw sewage164,707person-days of untreated BOD

Assumed spill rate while spilling: 62.9 - 396.6 L/s (central 158.0 L/s), from a dry-weather flow of 62.9 L/s.

Pollutant releasedLowCentralHighConcentration used (low / typical / high)
BOD₅ (organic load) 1,749 kg9,882 kg55,134 kg 40 / 90 / 200 mg/L
Low/high: Europe range, Ellis & Jenkins 2005; typical: UK, Ellis & Jenkins 2005 (both via botturi)
Suspended solids 4,592 kg46,667 kg198,757 kg 105 / 425 / 721 mg/L
Low/high: Europe range; typical: UK, Ellis & Jenkins 2005 (via botturi)
Ammonium-N 83 kg692 kg2,564 kg 1.9 / 6.3 / 9.3 mg/L
Low: Germany, Brombach 2005; typical/high: Paris range 3.3-9.3 midpoint and top, Gasperi 2012 (via botturi); no UK value found
Total phosphorus 52 kg285 kg1,489 kg 1.2 / 2.6 / 5.4 mg/L
Low/high: Paris, Gasperi 2012; typical: Slovakia (via botturi). UK figure of 10 mg/L treated as an outlier
E. coli 4.4 trillion organisms109.8 trillion organisms2.8 × 10¹⁵ organisms 10,000 / 100,000 / 1.0 million per 100 mL
Median range at CSO and retention-tank outlets, Stott et al. 2018 (via botturi); typical = log midpoint

Low combines the low spill rate with low concentrations, and high combines high with high, so the true figure is very likely inside the range. Long spills become more diluted as they go on, so the central figure tends to overstate the load of long events. The calculator does not estimate the effect on the receiving water, which depends on river flow or tide at the time of the spill.

Stratford Milcote STW

Storm tank at sewage works · discharges to River Avon

Spills 2025
26 (193 hours) · down 28% on 2024
Spills 2024
36 (489 hours)
Long-term average
32.3 spills a year (monitored since 2020)
Monitor uptime
100% of the year
Investigation
UWWTR investigation completed, Operational investigation completed
Improvement
Operational improvement ongoing
WFD catchment
Avon- Tramway Br Stratford to Workman Br Evesham (GB109054044401)
Outlet location
SP1799053040 (OS grid reference) · View on Apple Maps
EA ID / permit
SVT02235 · S/13/25718/R · company name: STRATFORD - MILCOTE STW (SSTO)

How the estimate works

  1. Dry-weather flow (DWF) = population × water use per person × (1 + infiltration). Water use is 136.5 L per person per day, England's per-capita consumption for 2024-25 [EA]. Infiltration of groundwater into sewers is taken as 0-40% of that flow [Escritt, via HBF]. The Environment Agency defines DWF as PG + I + E [EA].
  2. Population. The size of each works comes from the load entering it as reported under the Urban Waste Water Treatment Directive, in population equivalents (1 p.e. = 60 g of BOD a day) [UWWTD]. We treat population equivalent as population. That overstates flow where trade effluent adds load, and no official source links the two. Works serving fewer than 2,000 p.e. are not reported, so their size has to be entered by hand.
  3. Low spill rate = DWF. This is the method used by Giakoumis & Voulvoulis (2026), which they note likely underestimates storm loads [G&V].
  4. High spill rate = Formula A − flow to full treatment = (DWF + 1360P) − 3DWF. This is the largest flow the permit expects the storm tanks to handle before it passes on to treatment or overflows [EA]. The central rate is the geometric mean of the low and high rates.
  5. Volume = spill rate × hours spilling, with hours taken from the event duration monitor.
  6. Pollution = volume × published storm-sewage concentrations [Botturi et al.] [US EPA]. Organic load is also shown as person-days of untreated sewage at 60 g of BOD per person per day [UWWTD].

What this cannot tell you. It gives no real flow for any single spill, and no effect on the river or sea, which depends on the flow, tide and the other pressures on the water at the time. It gives no figure for spills from overflows on the sewer network, which serve catchments of unknown size. It is a way to put hours into rough physical terms, not a substitute for flow monitoring.

Sources

  1. EA: Water companies - environmental permits for storm overflows and emergency overflows
  2. EA: Water resources 2024 to 2025 - per capita consumption
  3. HBF: Foul sewer design - historic conventions (citing Escritt 1984 on infiltration)
  4. Giakoumis & Voulvoulis (2026), Environ. Sci.: Water Res. Technol., doi:10.1039/D5EW00860C
  5. Botturi et al. (2021), Crit. Rev. Environ. Sci. Technol. 51:1585 - CSO quality review, Table 2
  6. US EPA (2004) Report to Congress on CSOs and SSOs, chapter 4
  7. Urban Waste Water Treatment Directive, Article 2(6): 1 p.e. = 60 g BOD5/day
  8. Olympic-size swimming pool: 2,500 m³ at the nominal 2 m depth

← All Severn Trent Water works · Contains Environment Agency data licensed under the Open Government Licence v3.0. Spill start and stop times: © Environment Agency copyright and/or database right 2026. All rights reserved. They are water-company data and have not been verified by the Environment Agency. Works size: EEA Waterbase UWWTD. How to read the data.